Engineering PapersSearch

Engineering topics

Selzer, R. H.

Publications and source records attributed to Selzer, R. H..

At least 19 records

Leg muscle volume during 30-day 6-degree head-down bed rest with isotonic and isokinetic exercise training

Magnetic resonance imaging (MRI) was used to compare the effect of two modes of lower-extremity exercise training on the mass (volume) of posterior leg group (PLG) muscles (soleus, flexor hallucis longus, tibialis posterior, lateral and medial gastrocnemius, and flexor digitorum longus) on 19 men (ages 32-42 years) subjected to intense dynamic-isotonic (ITE, cycle ergometer, number of subjects (N) = 7), isokinetic (IKE, torque egrometer, N = 7), and no exercise (NOE, N = 5) training for 60 min/day during head-down bed rest (HDBR). Total volume of the PLG muscles decreased (p less than 0.05) similarly: ITE = 4.3 +/- SE 1.6%, IKE = 7.7 +/- 1.6%, and NOE = 6.3 +/- 0.8%; combined volume (N = 19) loss was 6.1 +/- 0.9%. Ranges of volume changes were 2.6% to -9.0% (ITE), -2.1% to -14.9% (IKE), and -3.4% to -8/1% (NOE). Correlation coefficients (r) of muscle volume versus thickness measured with ultrasonography were: ITE r + 0.79 (p less than 0.05), IKE r = 0.27 (not significant (NS)), and NOE r = 0.63 (NS). Leg-muscle volume and thickness were highly correlated (r = 0.79) when plasma volume was maintained during HDBR with ITE. Thus, neither intensive lower extremity ITE nor IKE training influence the normal non-exercised posterior leg muscle atrophy during HDBR. The relationship of muscle volume and thickness may depend on the mode of exercise training associated with the maintenance of plasma volume.

Greenleaf, J. E.

Comparison of computer- and human-derived coronary angiographic end-point measures for controlled therapy trials

The Cholesterol Lowering Atherosclerosis Study, a randomized angiographic clinical trial, demonstrated the beneficial effect of niacin/colestipol plus diet therapy on coronary atherosclerosis. Outcome was determined by panel-based estimates (viewed in both still and cine modes) of percent stenosis severity and change in native artery and bypass graft lesions. Computer-based quantitative coronary angiography (QCA) was also used to measure lesion and bypass graft stenosis severity and change in individual frames closely matched in orientation, opacification, and cardiac phase. Both methods jointly evaluated 350 nonoccluded lesions. The correlation between QCA and panel estimates of lesion size was 0.70 (p less than 0.0001) and for change in lesion size was 0.28 (p = 0.002). Agreement between the two methods in classifying lesion changes (i.e., regression, unchanged, or progression) occurred for 60% (210 of 350) of the lesions kappa +/- SEM = 0.20 +/- 0.05, p less than 0.001). The panel identified 442 nonoccluded lesions for which QCA stenosis measurements could not be obtained. Lesions not measurable by QCA included those with stenosis greater than 85% that could not be reliably edge tracked, segments with diffuse or ecstatic disease that had no reliable reference diameter, and segments for which matched frames could not be located. Seventy-nine lesions, the majority between 21% and 40% stenosis, were identified and measured by QCA but were not identified by the panel. This comparison study demonstrates the need to consider available angiographic measurement methods in relation to the goals of their use.

NASA Center JPL

Best estimate of luminal cross-sectional area of coronary arteries from angiograms

We have reexamined the problem of estimating the luminal area of an elliptically-shaped coronary artery cross section from two or more radiographic diameter measurements. The expected error is found to be much smaller than the maximum potential error. In the cae of two orthogonal views, closed form expressions have been derived for calculating the area and the uncertainty. Assuming that the underlying ellipse has limited ellipticity (major/minor axis ratio less than five), it is shown that the average uncertainty in the area is less than 14 percent. When more than two views are available, we suggest using a least-squares fit method to extract all available information from the data.

Lee, P. L.

Dynamical relations for left ventricular ejection - Flow rate, momentum, force and impulse

An investigation was carried out to quantitatively evaluate left ventricular volume flow rate, momentum, force and impulse derived from application of conservation principles for mass and momentum of blood within the ventricle during the ejection phase. An automated digital image processing system was developed and applied to left ventricular angiograms which are computer processed and analyzed frame by frame to determine the dynamical relations by numerical methods. The initial experience with force and impulse has indicated that neither quantity seemed to be a sensitive indicator of coronary artery disease as evaluated by qualitative angiography for the particular patient group studied. Utilization of the dynamical relations in evaluating human left ventricular performance requires improved means of measurement and interpretation of clinical studies.

Back, L. H.

Computer processing of radiographic images

In the past 20 years, a substantial amount of effort has been expended on the development of computer techniques for enhancement of X-ray images and for automated extraction of quantitative diagnostic information. The historical development of these methods is described. Illustrative examples are presented and factors influencing the relative success or failure of various techniques are discussed. Some examples of current research in radiographic image processing is described.

Selzer, R. H.

Computer assessment of atherosclerosis from angiographic images

A computer method for detection and quantification of atherosclerosis from angiograms has been developed and used to measure lesion change in human clinical trials. The technique involves tracking the vessel edges and measuring individual lesions as well as the overall irregularity of the arterial image. Application of the technique to conventional arterial-injection femoral and coronary angiograms is outlined and an experimental study to extend the technique to analysis of intravenous angiograms of the carotid and cornary arteries is described.

Selzer, R. H.

The identification of the variation of atherosclerosis plaques by invasive and non-invasive methods

Computer-enhanced visualization of coronary arteries and lesions within them is discussed, comparing invasive and noninvasive methods. Trial design factors in computer lesions assessment are briefly discussed, and the use of the computer edge-tracking technique in that assessment is described. The results of a small pilot study conducted on serial cineangiograms of men with premature atherosclerosis are presented. A canine study to determine the feasibility of quantifying atherosclerosis from intravenous carotid angiograms is discussed. Comparative error for arterial and venous injection in the canines is determined, and the mode of processing the films to achieve better visualization is described. The application of the computer edge-tracking technique to an ultrasound image of the human carotid artery is also shown and briefly discussed.

Selzer, R. H.

Computer measurement of arterial disease

Image processing technique quantifies human atherosclerosis by computer analysis of arterial angiograms. X-ray film images are scanned and digitized, arterial shadow is tracked, and several quantitative measures of lumen irregularity are computed. In other tests, excellent agreement was found between computer evaluation of femoral angiograms on living subjects and evaluation by teams of trained angiographers.

Armstrong, J.

Analysis of multiple imagery at Jet Propulsion Laboratory's Image Processing Laboratory

During the past decade advanced techniques have been developed at JPL for processing large volumes of imagery returned by the more recent planetary spacecraft. In addition, the Image Processing Laboratory has become involved in the processing of earth resources imagery acquired by Landsat and a variety of other sensors flown on aircraft and spacecraft. The trend within the facility has been toward the development of technology capable of processing increasingly larger image data bases. A variety of applications in both the planetary and earth observations areas involve the merging and/or processing of more than one image and often require the correlation of data acquired by a variety of sensors.

Green, W. B.

Computer quantitation of coronary angiograms

A computer technique is being developed at the Jet Propulsion Laboratory to automate the measurement of coronary stenosis. A Vanguard 35mm film transport is optically coupled to a Spatial Data System vidicon/digitizer which in turn is controlled by a DEC PDP 11/55 computer. Programs have been developed to track the edges of the arterial shadow, to locate normal and atherosclerotic vessel sections and to measure percent stenosis. Multiple frame analysis techniques are being investigated that involve on the one hand, averaging stenosis measurements from adjacent frames, and on the other hand, averaging adjacent frame images directly and then measuring stenosis from the averaged image. For the latter case, geometric transformations are used to force registration of vessel images whose spatial orientation changes.

Ledbetter, D. C.

Computer analysis of arteriograms

A computer system has been developed to quantify the degree of atherosclerosis in the human femoral artery. The analysis involves first scanning and digitizing angiographic film, then tracking the outline of the arterial image and finally computing the relative amount of roughness or irregularity in the vessel wall. The image processing system and method are described.

Selzer, R. H.

Digital image processing of vascular angiograms

A computer image processing technique was developed to estimate the degree of atherosclerosis in the human femoral artery. With an angiographic film of the vessel as input, the computer was programmed to estimate vessel abnormality through a series of measurements, some derived primarily from the vessel edge information and others from optical density variations within the lumen shadow. These measurements were combined into an atherosclerosis index, which was found to correlate well with both visual and chemical estimates of atherosclerotic disease.

Selzer, R. H.

Digital image processing of vascular angiograms

The paper discusses the estimation of the degree of atherosclerosis in the human femoral artery through the use of a digital image processing system for vascular angiograms. The film digitizer uses an electronic image dissector camera to scan the angiogram and convert the recorded optical density information into a numerical format. Another processing step involves locating the vessel edges from the digital image. The computer has been programmed to estimate vessel abnormality through a series of measurements, some derived primarily from the vessel edge information and others from optical density variations within the lumen shadow. These measurements are combined into an atherosclerosis index, which is found in a post-mortem study to correlate well with both visual and chemical estimates of atherosclerotic disease.

Selzer, R. H.

Digital computer processing of X-ray photos

Digital computers correct various distortions in medical and biological photographs. One of the principal methods of computer enhancement involves the use of a two-dimensional digital filter to modify the frequency spectrum of the picture. Another computer processing method is image subtraction.

Nathan, R.