Engineering Papers⌕ Search

Engineering topics

Seiden, A.

Publications and source records attributed to Seiden, A..

At least 37 records · Page 2

Charge collection in irradiated HV-CMOS detectors

Active silicon detectors built on p-type substrate are a promising technological solution for large area silicon trackers such as those at the High Luminosity LHC, but the radiation hardness of this novel approach has to be evaluated. Active n-in-p strip detector prototypes CHESS2 for ATLAS with different substrate resistivities in the range of 20-1000 Omega cm were irradiated with neutrons and protons up to a fluence of 2 x 10(15) n(eq) cm(-2) and 3.6 x 10(15) n(eq) cm(-2). Charge collection in passive test structures on the chip was evaluated using Edge-TCT and minimum ionising electrons from Sr-90. Results were used to assess radiation hardness of the detector in the given fluence range and to determine parameters of initial acceptor removal in different substrates.

active silicon detectors↗

Timing layers, 4- and 5-dimension tracking

The combination of precision space and time information in particle tracking, the so called 4D tracking, is being considered in the upgrade of the ATLAS, CMS and LHCb experiments at the High-Luminosity LHC, set to start data taking in 2024–2025. Regardless of the type of solution chosen, space–time tracking brings benefits to the performance of the detectors by reducing the background and sharpening the resolution; it improves tracking performances and simplifies tracks combinatorics. Space–time tracking also allows investigating new physics channels, for example it opens up the possibilities of new searches in long-living particles by measuring accurately the time of flight between the production and the decay vertexes. The foreseen applications of 4D tracking in experiments with very high acquisition rates, for example at HL-LHC, add one more dimension to the problem, increasing dramatically the complexity of the read-out system and that of the whole detector design: we call 5D tracking the application of 4D tracking in high rate environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector

For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at (z) = 3.5 m and covering the region 2.4 < (Eta) < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 Mu-m thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3x1.3 mm2 and arrays with 2x2 pads with a surface area of 2x2 mm2 or 3x3 mm2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few Mu-m. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3x1.3 mm 2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfill the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Studies of uniformity of 50 μ m low-gain avalanche detectors at the Fermilab test beam

In this study, we report measurements of the uniformity of time resolution, signal amplitude, and charged particle detection efficiency across the sensor surface of low-gain avalanche detectors (LGAD). Comparisons of the performance of sensors with different doping concentrations and different active thicknesses are presented, as well as their temperature dependence and radiation tolerance up to 6 x 10 14 n/cm 2 . Results were obtained at the Fermilab test beam facility using 120 GeV proton beams, and a high precision pixel tracking detector. LGAD sensors manufactured by the Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) were studied. The uniformity of the sensor response in pulse height before irradiation was found to have a 2% spread. The signal detection efficiency and timing resolution in the sensitive areas before irradiation were found to be 100% and 30–40 ps, respectively. A “no-response” area between pads was measured to be about 130 μm for CNM and 170μm for HPK sensors. After a neutron fluence of 6 x 10 14 n/cm 2 the CNM sensor exhibits a large gain variation of up to a factor of 2.5 when comparing metalized and non-metalized sensor areas. An irradiated CNM sensor achieved a time resolution of 30 ps for the metalized area and 40 ps for the non-metalized area, while a HPK sensor irradiated to the same fluence achieved a 30 ps time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence for C P violation in B + → K * ( 892 ) + π 0 from a Dalitz plot analysis of B + → K S 0 π + π 0 decays

We report a Dalitz plot analysis of charmless hadronic decays of charged B mesons to the final state K 0 S π + π 0 using the full BABAR data set of 470.9 ± 2.8 million B¯B events collected at the Υ(4S) resonance. We measure the overall branching fraction and CP asymmetry to be B(B + → K 0 π + π 0 ) = (31.8 ± 1.8 ± 2.1 +6.0 –0.0 ) × 10 –6 and A CP (B + → K 0 π + π 0 ) = 0.07 ± 0.05 ± 0.03 +0.02 –0.03 , where the uncertainties are statistical, systematic, and due to the signal model, respectively. This is the first measurement of the branching fraction for B + → K 0 π + π 0 . We find first evidence of a CP asymmetry in B + → K*(892) + π 0 decays: A CP (B + → K*(892) + π 0 ) = –0.52 ± 0.14 ± 0.04 +0.04 –0.02 . The significance of this asymmetry, including systematic and model uncertainties, is 3.4 standard deviations. As a result, we also measure the branching fractions and CP asymmetries for three other intermediate decay modes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation hardness studies of AMS HV-CMOS 350 nm prototype chip HVStripV1

CMOS active pixel sensors are being investigated for their potential use in the ATLAS inner tracker upgrade at the HL-LHC. The new inner tracker will have to handle a significant increase in luminosity while maintaining a sufficient signal-to-noise ratio and pulse shaping times. This paper focuses on the prototype chip "HVStripV1" (manufactured in the AMS HV-CMOS 350nm process) characterization before and after irradiation up to fluence levels expected for the strip region in the HL-LHC environment. The results indicate an increase of depletion region after irradiation for the same bias voltage by a factor of ≈2.4 and ≈2.8 for two active pixels on the test chip. As a result, there was also a notable increase in noise levels from 85 e – to 386 e – and from 75 e – to 277 e – for the corresponding pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for mixing-induced C P violation using partial reconstruction of B ¯ 0 → D * + X ℓ - ν ¯ ℓ and kaon tagging

We describe in detail a previously published measurement of CP violation in B 0 -B¯ 0 oscillations, based on an integrated luminosity of 425.7 fb -1 collected by the BABAR experiment at the PEPII collider. We apply a novel technique to a sample of about 6 million B¯ 0 →D* + ℓ - ν ℓ ¯ decays selected with partial reconstruction of the D*+ meson. The charged lepton identifies the flavor of one B meson at its decay time, the flavor of the other B is determined by kaon tagging. We determine a CP violating asymmetry ACP=(N(B0B0)-N(B¯ 0 B¯ 0 ))/(N(B 0 B 0 )+N(B¯ 0 B¯ 0 ))=(0.06±0.17 +0.38 -0.32 )% corresponding to Δ CP =1-|q/p|=(0.29±0.84 +1.88 -1.61 )×10 -3 . This measurement is consistent and competitive with those obtained at the B factories with dilepton events.

Experiment-HEP,HEPEX↗