Engineering Papers⌕ Search

Engineering topics

Segebade, Christian R

Publications and source records attributed to Segebade, Christian R.

An Overview Of Activation Analysis Techniques And Applications

Activation analysis can be performed using three different techniques, namely: activation with neutrons, with high-energy photons, and with charged particles. The different features as well as the advantages and drawbacks of these separate techniques will be discussed in this paper. During exposure radionuclides are produced in the activated sample and, the turn, the radiation emitted during radioactive decay (photons in the most cases) is measured with appropriate spectrometers. By evaluating the produced spectra, the elemental components of the activated material can be quantitatively ascertained. Through means of activation analysis, basically any kind of material can be studied. And frequently the sample can be analysed as is(instrumentally without complicated radiochemical separation steps), and in favourable cases, the analysis may be conducted non-destructively, i.e. without removing pieces of the interrogated sample. Several common applications will be discussed in this paper.

07 ISOTOPE AND RADIATION SOURCES↗

Cu-67 Photonuclear Production

Cu-67 is considered as one of the most promising radioisotopes for cancer therapy with monoclonal antibodies. Current production schemes using high-flux reactors and cyclotrons do not meet potential market need. In this paper we discuss Cu-67 photonuclear production through the reaction Zn-68({gamma},p)Cu-67. Computer simulations were done together with experiments to study and optimize Cu-67 yield in natural Zn target. The data confirms that the photonuclear method has potential to produce large quantities of the isotope with sufficient purity to be used in medical field.

07 ISOTOPE AND RADIATION SOURCES↗

Photon Activation Analysis at the Idaho Accelerator Center

Activation methods require minimal sample preparation and provide sufficiently high sensitivity for detecting the vast majority of the elements throughout the periodic table. In this paper we shall discuss photon activation analysis (PAA) at the Idaho Accelerator Center. The process of PAA begins with exposing a sample with photons in the energy range of 10 to 30 MeV. Many nuclides in the sample will become activated and, in turn, these radionuclides will decay by emitting characteristic radiation. These characteristic radiation decays are the telltale signatures for identifying elements which can then be measured with spectrometers such as a high-purity Germanium detector. PAA is not an 'absolute' method, as the samples under investigation must be irradiated along with a reference or calibrating material having a well-known elemental composition. The quantitative evaluation is performed through comparing the two resulting element spectra from the unknown sample and reference material. Besides the obvious advantage of being non-destructive, PAA has minimal contamination issues. Moreover, materials that are difficult to treat chemically, such as certain refractory metals, dusts, ashes, etc., offer no hindrance to the technique of PAA. A further advantage is that PAA is very well suited for investigated minute samples (sub-milligram dust particles) to very large ones (in the multi-kg range). PAA is a robust technique as there are no real limitations concerning the nature of material to be studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon Activation Analysis--An Analytical Application Of High-Energy Electron Accelerators

Photon activation analysis (PAA) was introduced about contemporarily with the other activation analysis methods (neutron, NAA, and charged particle activation, CPAA). Nonetheless, for different reasons, PAA has been applied less frequently than the other techniques mentioned. The incident photon energy should exceed about 12 MeV (except in some special rare applications) so as to obtain appreciably high activity yields of the product nuclides. Thus, cyclic electron accelerators (LINACs or microtrons) are used for activation preferably. The predominant photonuclear reaction is of the ({gamma},n)-type. Thus, normally neutron-deficient nuclides are produced. These usually emit gamma rays, annihilation quanta and characteristic X-ray fluorescence, all of whom can be used for analytical evaluation. The spectrometry equipment is the same as used for the other activation techniques (semiconductor detectors, sodium iodide crystals in coincidence geometry). Being uncharged high energy photons have a large penetration power, thus do not suffer from strong matrix absorption. Although not having a detection power as large as in NAA (in the most cases), PAA offers several further convincing advantages, e.g. several elements not or hardly detectable by NAA can be analysed: Titanium, nickel, thallium, lead, bismuth and, in particular, the light elements carbon, nitrogen, oxygen, fluorine, phosphorus. Several typical applications will be described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗