Engineering Papers⌕ Search

Engineering topics

Schweppe, John E

Publications and source records attributed to Schweppe, John E.

Accurate Modeling of the Terrestrial Gamma-Ray Background for Homeland Security Applications

Abstract–The Pacific Northwest National Laboratory has developed computer models to simulate the use of radiation portal monitors to screen vehicles and cargo for the presence of illicit radioactive material. The gamma radiation emitted by the vehicles or cargo containers must often be measured in the presence of a relatively large gamma-ray background mainly due to the presence of potassium, uranium, and thorium (and progeny isotopes) in the soil and surrounding building materials. This large background is often a significant limit to the detection sensitivity for items of interest and must be modeled accurately for analyzing homeland security situations. Calculations of the expected gamma-ray emission from a disk of soil and asphalt were made using the Monte Carlo transport code MCNP and were compared to measurements made at a seaport with a high-purity germanium detector. Analysis revealed that the energy spectrum of the measured background could not be reproduced unless the model included gamma rays coming from the ground out to distances of at least 300 m. The contribution from beyond about 50 m was primarily due to gamma rays that scattered in the air before entering the detectors rather than passing directly from the ground to the detectors. These skyshine gamma rays contribute tens of percent to the total gamma-ray spectrum, primarily at energies below a few hundred keV. The techniques that were developed to efficiently calculate the contributions from a large soil disk and a large air volume in a Monte Carlo simulation are described and the implications of skyshine in portal monitoring applications are discussed.

54 ENVIRONMENTAL SCIENCES↗

Terrestrial Background Reduction in RPM Systems by Direct Internal Shielding

Gamma-ray detection systems that are close to the earth or other sources of background radiation often require shielding, especially when trying to detect a relatively weak source. One particular case of interest that we address in this paper is that encountered by the Radiation Portal Monitors (RPMs) systems placed at border-crossing Ports of Entry (POE). These RPM systems are used to screen for illicit radiological materials, and they are often placed in situations where terrestrial background is large. In such environments, it is desirable to consider simple physical modifications that could be implemented to reduce the effects from background radiation without affecting the flow of traffic and the normal operation of the portal. Simple modifications include adding additional shielding to the environment, either inside or outside the apparatus. Previous work [2] has shown the utility of some of these shielding configurations for increasing the Signal to Noise Ratio (SNR) of gross-counting RPMs. Because the total cost for purchasing and installing RPM systems can be quite expensive, in the range of hundreds of thousands of dollars for each cargo-screening installation, these shielding variations may offer increases in detection capability for relatively small cost. Several modifications are considered here in regard to their real-world applicability, and are meant to give a general idea of the effectiveness of the schemes used to reduce background for both gross-counting and spectroscopic detectors. These scenarios are modeled via the Monte-Carlo N-Particle (MCNP) code package [1] for ease of altering shielding configurations, as well as enacting unusual scenarios prior to prototyping in the field. The objective of this paper is to provide results representative of real modifications that could enhance the sensitivity of this, as well as the next generation of radiation detectors. The models used in this work were designed to provide the most general results for an RPM. These results are therefore presented as general guidance on what shielding configurations will be the most valuable for a generalized RPM, considered in light of their economic and geometric possibility in the real world.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy Calibration of Gamma Spectra in Plastic Scintillators using Compton Kinematics

This paper describes a simple and practicable method for assigning energy values to gamma-ray pulse-height distributions measured with polyvinyl toluene based detectors. It is based upon the characteristic shape of the spectrum in the region of maximum energy deposition resulting from a single Compton scattering. The validity of this method is first demonstrated by applying it to a set of NaI(Tl) spectra, and comparing those results to the standard photo-peak method of calibrating the same spectra. The method is then applied to a set of polyvinyl toluene derived spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source Injection Distribution Functions for Alarm Algorithm Testing

The development and testing of improved alarm algorithms is an ongoing priority of the Radiation Portal Monitor Project (RPMP) at Pacific Northwest National Laboratory (PNNL). Improved algorithms have the potential to reduce the impediments that radiation screening presents to the flow of commerce, without affecting the detection sensitivity to sources of interest. However, assessing alarm-algorithm performance involves careful calculation of detection probabilities and nuisance/false alarm rates for any algorithm that may be used in the field. To establish statistical confidence, such a task requires a large amount of data from drive-through (or “dynamic”) scenarios both with, and without, radioactive sources of interest present; but obtaining actual field data to meet this need is not feasible. Instead, an “injection-study” procedure is being used to approximate how the profiles of actual drive-through commercial data would change with the presence of sources of interest. This procedure adds net-counts from a pre-defined set of simulated sources to raw, gross-count drive-through data randomly selected from archived cargo data collected from deployed radiation portal monitors (RPMs). (PIET-43741-TM-480)

Robinson, Sean M↗

Development of a Detector Model for Generation of Synthetic Radiographs of Cargo Containers

Creation of synthetic cargo-container radiographs that possess attributes of their empirical counterparts requires accurate models of the imaging system response. Synthetic radiographs serve as surrogate data in studies aimed at determining system effectiveness for detecting target objects when it is impractical to collect a large set of empirical radiographs. In the case where a detailed understanding of the detector system is available, an accurate detector model can be derived from first principles. In the absence of this detail, it is necessary to derive empirical models of the imaging-system response from radiographs of well-characterized objects. Such a case is the topic of this work, where we demonstrate the development of an empirical model of a gamma-ray radiography system with the intent of creating a detector-response model that translates uncollided photon transport calculations into realistic synthetic radiographs. The detector-response model is calibrated to field measurements of well-characterized objects thus incorporating properties such as system sensitivity, spatial resolution, contrast, and noise.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗