Geometry and properties of the plasma in a quadrupole ion pump

The diameter of the plasma in a quadrupole ionization gauge and quadrupole ion pump has been measured as a function of pressure. The radio-frequency quadrupole systems are tuned in such a way that electrons remain on stable trajectories in the center of the tube. Being emitted at one end, the electrons encounter an inverted field at the other end so that they travel on spiral paths back and forth until they collide with the rest gas molecules, producing ions which are collected as an ion current at a cylinder surrounding the four hyperbolically shaped quadrupole electrodes.

Schwarz, H.

Quadrupole ion pump performance characteristics.

A new nonmagnetic ion pump is described that resembles a quadrupole ionization gauge. The dimensions are larger, and hyperbolically shaped electrodes replace the four rods. Pumping speeds (4-100 liters per sec) for different gases at various peak voltages (1000-3000 V) at corresponding frequencies (57-100 MHz) and at different pressures (10 microtorr to 1 nanotorr) are reported.

Schwarz, H.

Quadrupole ionization gauge.

Nonmagnetic ionization gage consisting of quadrupole lens systems excited at HF, discussing electron focusing during operation