Engineering PapersSearch

Engineering topics

Schwartz, D. A.

Publications and source records attributed to Schwartz, D. A..

At least 19 records

Optics Requirements For The Generation-X X-Ray Telescope

US, European, and Japanese space agencies each now operate successful X-ray missions -- NASA s Chandra, ESA s XMM-Newton, and JAXA s Suzaku observatories. Recently these agencies began a collaboration to develop the next major X-ray astrophysics facility -- the International X-ray Observatory (IXO) -- for launch around 2020. IXO will provide an order-of-magnitude increase in effective area, while maintaining good (but not sub-arcsecond) angular resolution. X-ray astronomy beyond IXO will require optics with even larger aperture areas and much better angular resolution. We are currently conducting a NASA strategic mission concept study to identify technology issues and to formulate a technology roadmap for a mission -- Generation-X (Gen-X) -- to provide these capabilities. Achieving large X-ray collecting areas in a space observatory requires extremely lightweight mirrors.

O'Dell, S. .

Orbital Verification of the CXO High-Resolution Mirror Assembly Alignment and Vignetting

Prior to launch, the High Resolution Mirror Assembly (HRMA) of the Chandra X-ray Observatory underwent extensive ground testing at the X-ray Calibration Facility (XRCF) at the Marshall Space Flight Center in Huntsville. Observations made during the post-launch Orbital Activation and Calibration period, allow the on-orbit condition of the X-ray optics to be assessed. Based on these ground-based and on-orbit data, we examine the alignment of the x-ray optics based on the PSF, and the boresight and alignment of the optical axis alignment relative to the detectors. We examine the vignetting and the single reflection ghost suppression properties of the telescope. Slight imperfections in alignment lead to a small azimuthal dependence of the off-axis area; the morphology of off-axis images also shows an additional small azimuthal dependence varying as 1/2 the off-axis azimuth angle.

Gaetz, T. J.

Orbital Measurement and Verification of the Chandra X-Ray Observatory's PSF

The recently launched Chandra x-ray Observatory (CXO) was designed to have the sharpest angular resolution yet of any x-ray telescope. Detailed modeling and metrology of the optics followed by extensive testing at the X-ray Calibration Facility at the Marshall p Space Flight Center in Huntsville, Alabama, indicated that the optics were performing exceedingly well, within our ability to account for distortion of the mirrors due to gravity, and the effects of finite distance and size of the x-ray generator. Thus it was only on-orbit that we expected to directly observe the specified half arcsecond performance. We present here results of the on-orbit calibration of the point spread function (PSF), comparing it with our predictions. We discuss how the PSF varies with source location in the telescope field of view, as well as with the spectral energy distribution of the source.

Jerius, D.

Absolute Effective Area of the Chandra High-Resolution Mirror Assembly

The Chandra X-ray Observatory was launched in July 1999, and is returning exquisite sub-arcsecond x-ray images of star groups, supernova remnants, galaxies, quasars, and clusters of galaxies. In addition to being the premier X-ray observatory in terms of angular and spectral resolution, Chandra is the best calibrated X-ray facility ever flown. We discuss here the calibration of the effective area of the High Resolution Mirror Assembly. Because we do not know the absolute X-ray flux density of any celestial source, this must be based primarily on ground measurements and on modeling. In particular, we must remove the calibrated modeled responses of the detectors and gratings to obtain the mirror area. For celestial sources which may be assumed to have smoothly varying spectra, such as the Crab Nebula, we may verify the continuity of the area calibration as a function of energy. This is of significance in energy regions such as the Ir M-edges, or near the critical grazing angle cutoff of the various mirror shells.

Schwartz, D. A.

Analysis of the PKS0637-752 X-Ray Jet System

The X-ray jet emitted from the quasar PKS0637-752 is the largest and most luminous detected to date. It extends 10 arcsec west of the nucleus, and is coincident with GHz radio jet emission in this region. If the individual X-ray/optical/radio knots in this jet were detected as isolated objects, they might be classified as BL Lac objects or quasars. We present a detailed analysis of the Chandra observations of this system, including a search for an intra-cluster medium to confine the jet, and limits to X-ray emission from the eastern radio knot and past the bend of the radio jet to the northwest. The projection in the plane of the sky implies that the X-ray jet is an aligned extension of the pc-scale jet, for which VLBI/VSOP observations show super-luminal motion with an apparent velocity of 11c. In this case, the X-ray jet is of order 1 Mpc in length, and explaining the X-ray emission mechanism presents new challenges.

Schwartz, D. A.

Predictions of the On-Orbit Performance of AXAF's Optics

The AXAF optics and science instruments have recently undergone a battery of tests at the Marshall Space Flight Center X-Ray Calibration Facility to determine their spatial and spectral performance. We have combined these data, detailed maps of the optics, surfaces, precise measurements of surface roughness and reflectivity, and detailed mechanical models of the optics and their support structures to arrive at predictions of the optics' on-orbit performance. We present on- and off-axis effective areas, encircled energies, and PSFS.

Jerius, D.

The X-ray selected cataclysmic variables H0459 + 246 and H0857 - 242

We report the discovery of two cataclysmic variables located with the assistance of X-ray positions from the HEAO 1 Modulation Collimator and the Large-Area Sky Survey. Each case is distinguished by evidence of two periodic modulations that appear to represent the orbital period and the spin period of the white dwarf, respectively. The first case, H0459 + 246, has been observed optically during faint states (V approximately 16), in which there are spectral features of both an accretion disk and a K star. The light curves in the V and I bands are consistent with ellipsoidal variations in the secondary stars with a binary period of 9.952 hr. X-ray observations with EXOSAT reveal a strong pulsation with a period approximately 62 minutes. This result confirms an 'intermediate polar' classification for H0459 + 246. The pulsation is observed at 63.2 minutes in the optical I band. The long orbital period opens the possibility that H0459 + 246 is a relatively young intermediate polar that might evolve into a polar. The second case, H0857--242, shows radial velocity modulations at 1.78 hr along with photometric variations at a period approximately 49 minutes. The latter are observed only during the decay phase of dwarf nova outbursts (13 less than V less than 17), which apparently recur frequently. Given the lack of X-ray monitoring observations and the absence of proof that the 49 minute periodicity is coherent over long time-scales, we regard H0857--242 as a candidate intermediate polar. Photographic records from th e Harvard Observatory Plate Library further reveal superoutbursts for H0857--242 (V approximately 11). A bright X-ray source that is both an intermediate polar and a continually cycling dwarf nova may provide an effective means of measuring the time delay for the arrival of accreting matter at the white dwarf surface, relative to the onset of optical brightening.

Remillard, R. A.

Twenty-two emission-line AGNs from the HEAO-1 X-ray survey

We report 22 emission-line AGN as bright, hard X-ray sources. All of them appear to be new classifications with the exception of one peculiar IRAS source which is a known quasar and has no published spectrum. This sample exhibits a rich diversity in optical spectral properties and luminosities, ranging from a powerful broad-absorption-line quasar to a weak nucleus embedded in a nearby NGC galaxy. Two cases confer X-ray luminosities in excess of 10 exp 47 erg/s. However, there is a degree of uncertainty in the X-ray identification for the AGN fainter than V about 16.5. Optically, several AGN exhibit very strong Fe II emission. One Seyfert galaxy with substantial radio flux is an exception to the common association of strong Fe II emission and radio-quiet AGN. The previously recognized IRAS quasar shows extreme velocities in the profiles of the forbidden lines; the 0 III pair is broadened to the point that the lines are blended. Several of these AGN show evidence of intrinsic obscuration, illustrating the effectiveness of hard X-ray surveys in locating AGN through high column density.

Remillard, R. A.

Precision of the calibration of the AXAF Engineering Test Article (VETA) mirrors

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.

Schwartz, D. A.

Reflectance calibrations of AXAF mirror samples at absorption edges using synchrotron radiation

We are developing a system to calibrate reflectances of witness coupons to the AXAF flight mirrors at the National Synchrotron Light Source over the 0.05-12 keV energy range. These witness coupons will be coated in the same process as the AXAF mirror elements. One of the key issues is the accurate determination of mirror efficiencies across the absorption edges of the mirror coating elements. We present a series of reflectance measurements with 2 eV resolution of a nickel-coated flat mirror in the region of the Ni L-II (870 eV) and L-III (853 eV) absorption edges. Scans of reflectance versus grazing angle at fixed energies in this region show distinct interference fringes at grazing angles larger than the critical angle which are extinguished as the photon energy is increased beyond the low point of the L-III edge, indicating total absorption of the evanescent wave within the Ni film. At 51 arc minutes grazing angle, measured reflectance decreases smoothly by 35 percent and then recovers in an 8 eV band at the L-III edge. We have also measured reflectances in the M absorption edge region for gold, platinum, and iridium coated mirrors. We derive optical parameters n and k specific to the film for comparison to the existing data tables.

Graessle, D. E.

VETA-I x ray test analysis

This interim report presents some definitive results from our analysis of the VETA-I x-ray testing data. It also provides a description of the hardware and software used in the conduct of the VETA-I x-ray test program performed at the MSFC x-ray Calibration Facility (XRCF). These test results also serve to supply data and information to include in the TRW final report required by DPD 692, DR XC04. To provide an authoritative compendium of results, we have taken nine papers as published in the SPIE Symposium, 'Grazing Incidence X-ray/EUV Optics for Astronomy and Projection Lithography' and have reproduced them as the content of this report.

Brissenden, R. J. V.

Precision of the calibration of the AXAF engineering test article (VETA) mirrors

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.

Schwartz, D. A.

S-154 in the Large Magellanic Cloud - Spectral evolution from a luminous Fe II variable to a symbiotic-like star

The evolution of the emission-line Star S-154, between February and December 1988, from a low-excitation 'Fe II star' into a high-excitation state that resembles symbiotic stars, is traced. It is inferred that the spectral type of central stars do not always dominate the physical conditions in the circumstellar material and thereby determine the nebular classification. The membership of S-154 in the LMC was confirmed with a radial velocity measurement of +274 km/s. The historical light curve (1880-1990) obtained from 346 photograph plates of the Harvard Plate Library exhibits about 4 mag of variations, with an MB range of -6 to -2. No evidence was found for coherent modulations that would represent the orbital period of a symbiotic binary.

Remillard, R. A.

Rapid oscillations in cataclysmic variables. VIII - YY Draconis (=3A 1148 + 719)

A 16th magnitude cataclysmic variable presumably a dwarf nova, was detected near one of the positions permitted for the hard (2-10 keV) X-ray source 3A 1148 + 719. The optical and UV spectra of YY Dra are fairly typical of cataclysmic variables, except that the TiO absorption bands of an M dwarf can be seen for greater than 5000 A. This shows that the accretion disk is intrinsically faint in quiescence, suggesting a very low accretion rate. Yet the fairly blue continuum slope in the vacuum UV indicates the presence of a small hot object, presumably the white dwarf. The radial velocities at H-alpha indicate a 4.0-hr orbital period, and the IR light curve appears to show the expected 'double-humped' waveform from the distorted secondary. High-speed photometry in the U band reveals a stable periodicity of about 1-percent semiamplitude at a period of 275 s, with some power also in the subharmonic at about 550 s.

Patterson, J.

Development of high resolution imaging detectors for x ray astronomy

This final report summarizes our past activities and discusses the work performed over the period of 1 April 1990 through 1 April 1991 on x-ray optics, soft x-ray (0.1 - 10 KeV) imaging detectors, and hard x-ray (10 - 300 KeV) imaging detectors. If microchannel plates (MCPs) can be used to focus x-rays with a high efficiency and good angular resolution, they will revolutionize the field of x-ray optics. An x-ray image of a point source through an array of square MCP pores compared favorably with our ray tracing model for the MCP. Initial analysis of this image demonstrates the feasibility of MCPs for soft x-rays. Our work continues with optimizing the performance of our soft x-ray MCP imaging detectors. This work involves readout technology that should provide improved MCP readout devices (thin film crossed grid, curved, and resistive sheets), defect removal in MCPs, and photocathode optimization. In the area of hard x-ray detector development we have developed two different techniques for producing a CsI photocathode thickness of 10 to 100 microns, such that it is thick enough to absorb the high energy x-rays and still allow the photoelectrons to escape to the top MCP of a modified soft x-ray imaging detector. The methods involve vacuum depositing a thick film of CsI on a strong back, and producing a converter device that takes the place of the photocathode.

Murray, S. S.

Feasibility study of the use of synchrotron radiation in the calibration of AXAF - Initial reflectivity results

The 1-percent calibration accuracy goal of the Advanced X-ray Astrophysics Facility is being approached by way of an experiment at the National Synchrotron Light Source that will demonstrate the accuracy achievable in reflectance measurements conducted on coated flat mirrors in the 50 eV-12 keV energy range. The coatings will be of commercially produced Au, Ni, and Ir, deposited either by sputtering or by e-beam deposition. Optical constants will be estimated via the reflectance vs. angle-of-incidence method.

Graessle, D. E.

H1722 + 119 - A highly polarized X-ray-selected BL Lacertae object

A 15th-mag, X-ray-selected BL Lac object, H1722 + 119, has been discovered to possess a steep X-ray spectrum with power-law energy index near 1.3; radio measurements indicate a variable, compact source with 1.4-4.9 GHz power-law energy index of 0.04. The optical-IR polarization of H1722 + 119 reaches a maximum of 17 percent, which is much higher than other X-ray-selected BL Lac objects. The degree of polarization is found to be wavelength-dependent, decreasing monotonically toward the IR.

Brissenden, R. J. V.

Two X-ray-selected BL Lacertae objects observed with the HEAO 1 scanning modulation collimator

Two 16th magnitude BL Lac objects, H1101 - 232 and H1426 + 428, have been discovered. Each is a persistent and relatively bright X-ray source. A 2.7 percent linear polarization is measured in the optical emission or H101 - 232. The X-ray identification of H1426 + 428 is confirmed in an Exosat observation. The X-ray spectrum is well-modeled by a power law with an energy index of 1.19. Both BL Lac objects exhibit high f(x)/f(opt) ratios and they show a distinct resemblance to other X-ray selected BL Lac objects. The host galaxies are about 18th mag with angular diameters of about 20 arcsec and each may be the dominant member of a cluster of galaxies. Additional wide-slit spectroscopy reveals faint absorption features with redshifts of 0.129 for H1426 + 428 and 0.186 for H1101 - 232. The implied X-ray and optical luminosities exceed 10 to the 45th ergs/s for both BL Lac nuclei, assuming isotropic emission.

Remillard, R. A.