Engineering PapersSearch

Engineering topics

Schlecht, Erich

Publications and source records attributed to Schlecht, Erich.

At least 19 records

Technology Maturation for Cloud Ice Radiometers

Global measurements of ice in clouds, both the amount and particle size distribution, are critically needed to reduce uncertainties in global climate models. The retrieval of this information is best achieved with a range of receiver channels across the submillimeter wave range. Advancement of low noise Indium Phosphide (InP) MMIC amplifier technology to 25-nm gate length enabled us to develop miniature submillimeter-wave receivers for a CubeSat scale instrument that achieves 6 km spatial resolution. We developed the 25-nm InP MMICs and radiometer receivers for 240, 310, 380, 670 GHz. The 25-nm InP MMIC technology was thermal vacuum tested to reduce risk for future space mission.

Duffy, Maxwell

The Advanced Microwave Radiometer – Climate Quality (AMR-C) Instrument for Sentinel-6

The Advanced Microwave Radiometer – Climate Quality (AMR-C) is designed to measure the path delay due to atmospheric water vapor along Sentinel-6 altimeter path over one decade. The AMR-C receiver is based on heritage from previous AMR instruments with the addition of a THz-frequency radiometer, the High Resolution Microwave Radiometer (HRMR), for improved coastal zone accuracy and a Supplemental Calibration System (SCS) to meet level 3 requirements that the path delay error due to the altimeter-derived sea surface height be less at 0.8 cm and the path delay stability be maintained to 0.7 mm averaged over a 1-year time period.

Maiwald, Frank

A 2 Thz Schottky Solid-State Heterodyne Receiver for Atmospheric Studies

Obtaining temperature, pressure, and composition profiles along with wind velocities in the Earth's thermosphere/ionosphere system is a key NASA goal for understanding our planet. We report on the status of a technology development effort to build an all-solid-state heterodyne receiver at 2.06 terahertz that will allow the measurement of the 2.06 terahertz [OI] line for altitudes greater than 100 kilometers. The receiver front end features low-parasitic Schottky diode mixer chips that are driven by a local oscillator (LO) source using Schottky diode based multipliers. The multiplier chain consists of a 38 gigahertz oscillator followed by a set of three cascaded triplers at 114 gigahertz, 343 gigahertz and 1.03 terahertz.

Treuttel, Jeanne

THz Limb Sounder (TLS) for Lower Thermospheric Wind, Oxygen Density, and Temperature

Neutral winds are one of the most critical measurements in the lower thermosphere and E region ionosphere (LTEI) for understanding complex electrodynamic processes and ion-neutral interactions. We are developing a high-sensitivity, low-power, noncryogenic 2.06 THz Schottky receiver to measure wind profiles at 100-140 km. The new technique, THz limb sounder (TLS), aims to measure LTEI winds by resolving the wind-induced Doppler shift of 2.06 THz atomic oxygen (OI) emissions. As a transition between fine structure levels in the ground electronic state, the OI emission is in local thermodynamic equilibrium(LTE) at altitudes up to 350km. This LTE property, together with day-and-night capability and small line-of-sight gradient, makes the OI limb sounding a very attractive technique for neutral wind observations. In addition to the wind measurement, TLS can also retrieve [OI] density and neutral temperature in the LTEI region. TLS leverages rapid advances in THz receiver technologies including subharmonically pumped (SHP)mixers and Schottky-diode-based power multipliers. Current SHP Schottky receivers have produced good sensitivity for THz frequencies at ambient environment temperatures (120-150 K), which are achievable through passively cooling in spaceflight. As an emerging technique, TLS can fill the critical data gaps in the LTEI neutral wind observations to enable detailed studies on the coupling and dynamo processes between charged and neutral molecules.

wind profiles

Cryogenic Amplifier Based Receivers at Submillimeter Wavelengths

The operating frequency of InP high electron mobility transistor (HEMT) based amplifiers has moved well in the submillimeter-wave frequencies over the last couple of years. Working amplifiers with usable gain in waveguide packages has been reported beyond 700 GHz. When cooled cryogenically, they have shown substantial improvement in their noise temperature. This has opened up the real possibility of cryogenic amplifier based heterodyne receivers at submillimeter wavelengths for ground-based, air-borne, and space-based instruments for astrophysics, planetary, and Earth science applications. This paper provides an overview of the science applications at submillimeter wavelengths that will benefit from this technology. It also describes the current state of the InP HEMT based cryogenic amplifier receivers at submillimeter wavelengths.

cryogenically cooled superconductorinsulator- supe

Dual-Band Optical Bench for Terahertz Radiometer for Outer Planet Atmospheres (TROPA)

We have developed a wide-band dual frequency spectrometer for use in deep space planetary atmospheric spectroscopy. The instrument uses a dual-band architecture, both to be able to observe spectral lines from a wide range of atmospheric species, and to allow a higher precision retrieval of temperature/pressure/partial pressure and wind profiles. This dual-band approach requires a new design for the optical bench to couple both frequencies into their respective receivers.

submillitmeter

Local Oscillator Sub-Systems for Array Receivers in the 1-3 THz Range

Recent results from the Heterodyne Instrument for the Far-Infrared (HIFI) on the Herschel Space Telescope have confirmed the usefulness of high resolution spectroscopic data for a better understanding of our Universe. This paper will explore the current status of tunable local oscillator sources with emphasis on building a multi-pixel LO subsystem for the scientifically important CII line around 1908 GHz. Recent results have shown that over 50 microwatts of output power at 1.9 THz are possible with an optimized single pixel LO chain. These power levels are now sufficient to pump array receivers in this frequency range. Further power enhancement can be obtained by cooling the chain to 120 K or by utilizing in-phase power combining technology.

local oscillators

A 2.5-2.7 THz Room Temperature Electronic Source

We report on a room temperature 2.5 to 2.7 THz electronic source based on frequency multipliers. The source utilizes a cascade of three frequency multipliers with W-band power amplifiers driving the first stage multiplier. Multiple-chip multipliers are utilized for the two initial stages to improve the power handling capability and a sub-micron anode is utilized for the final stage tripler. Room temperature measurements indicate that the source can put out a peak power of about 14 microwatts with more than 4 microwatts in the 2.5 to 2.7 THz range.

Varactor diodes

Terahertz Array Receivers with Integrated Antennas

Highly sensitive terahertz heterodyne receivers have been mostly single-pixel. However, now there is a real need of multi-pixel array receivers at these frequencies driven by the science and instrument requirements. In this paper we explore various receiver font-end and antenna architectures for use in multi-pixel integrated arrays at terahertz frequencies. Development of wafer-level integrated terahertz receiver front-end by using advanced semiconductor fabrication technologies has progressed very well over the past few years. Novel stacking of micro-machined silicon wafers which allows for the 3-dimensional integration of various terahertz receiver components in extremely small packages has made it possible to design multi-pixel heterodyne arrays. One of the critical technologies to achieve fully integrated system is the antenna arrays compatible with the receiver array architecture. In this paper we explore different receiver and antenna architectures for multi-pixel heterodyne and direct detector arrays for various applications such as multi-pixel high resolution spectrometer and imaging radar at terahertz frequencies.

direct detector arrays

Multiple Differential-Amplifier MMICs Embedded in Waveguides

Compact amplifier assemblies of a type now being developed for operation at frequencies of hundreds of gigahertz comprise multiple amplifier units in parallel arrangements to increase power and/or cascade arrangements to increase gains. Each amplifier unit is a monolithic microwave integrated circuit (MMIC) implementation of a pair of amplifiers in differential (in contradistinction to single-ended) configuration. Heretofore, in cascading amplifiers to increase gain, it has been common practice to interconnect the amplifiers by use of wires and/or thin films on substrates. This practice has not yielded satisfactory results at frequencies greater than 200 Hz, in each case, for either or both of two reasons: Wire bonds introduce large discontinuities. Because the interconnections are typically tens of wavelengths long, any impedance mismatches give rise to ripples in the gain-vs.-frequency response, which degrade the performance of the cascade.

Kangaslahti, Pekka

Improved Speed and Functionality of a 580-GHz Imaging Radar

With this high-resolution imaging radar system, coherent illumination in the 576-to-589-GHz range and phase-sensitive detection are implemented in an all-solid-state design based on Schottky diode sensors and sources. By employing the frequency-modulated, continuous-wave (FMCW) radar technique, centimeter-scale range resolution has been achieved while using fractional bandwidths of less than 3 percent. The high operating frequencies also permit centimeter-scale cross-range resolution at several-meter standoff distances without large apertures. Scanning of a single-pixel transceiver enables targets to be rapidly mapped in three dimensions, so that the technology can be applied to the detection of concealed objects on persons.

Dengler, Robert

High Power Local Oscillator Sources for 1-2 THz

Recent results from the Heterodyne Instrument for Far-Infrared (HIFI) on the Herschel Space Telescope have confirmed the usefulness of high resolution spectroscopic data for a better understanding of our Universe. This paper will explore the current status of tunable local oscillator sources beyond HIFI and provide demonstration of how power combining of GaAs Schottky diodes can be used to increase both power and upper operating frequency for heterodyne receivers. Availability of power levels greater than 1 watt in the W-band now makes it possible to design a 1900 GHz source with more than 100 microwatts of expected output power.

Schottky diodes

Wide-Band Heterodyne Submillimetre Wave Spectrometer for Planetary Atmospheres

We present calculations and measurements on a passive submillimetre wave spectroscopic sounder to gather data on the thermal structure, dynamics and composition of the upper atmosphere of a planet, e.g. the stratosphere of Jupiter, or the entire thickness of the atmosphere of Mars. The instrument will be capable of measuring wind speeds, temperature, pressure, and key constituent concentrations in the stratosphere of the target planet. This instrument consists of a Schottky diode based front end and a digital back-end spectrometer. It differs from previous space-based spectrometers in its combination of wide tunability (520-590 GHz), and rapid frequency switching between widely spaced lines within that range. This will enable near simultaneous observation of multiple lines, which is critical to the reconstruction of atmospheric pressure and density versus altitude profiles. At the same time frequency accuracy must be high to enable wind speeds to be determined directly by measurement of the line's Doppler shift.

Submillimeter

Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer

This device is a biasable, submillimeter-wave, balanced mixer fabricated using JPL s monolithic membrane process a simplified version of planar membrane technology. The primary target application is instrumentation used for analysis of atmospheric constituents, pressure, temperature, winds, and other physical and chemical properties of the atmospheres of planets and comets. Other applications include high-sensitivity gas detection and analysis. This innovation uses a balanced configuration of two diodes allowing the radio frequency (RF) signal and local oscillator (LO) inputs to be separated. This removes the need for external diplexers that are inherently narrowband, bulky, and require mechanical tuning to change frequency. Additionally, this mixer uses DC bias-ability to improve its performance and versatility. In order to solve problems relating to circuit size, the GaAs membrane process was created. As much of the circuitry as possible is fabricated on-chip, making the circuit monolithic. The remainder of the circuitry is precision-machined into a waveguide block that holds the GaAs circuit. The most critical alignments are performed using micron-scale semiconductor technology, enabling wide bandwidth and high operating frequencies. The balanced mixer gets superior performance with less than 2 mW of LO power. This can be provided by a simple two-stage multiplier chain following an amplifier at around 90 GHz. Further, the diodes are arranged so that they can be biased. Biasing pushes the diodes closer to their switching voltage, so that less LO power is required to switch the diodes on and off. In the photo, the diodes are at the right end of the circuit. The LO comes from the waveguide at the right into a reduced-height section containing the diodes. Because the diodes are in series to the LO signal, they are both turned on and off simultaneously once per LO cycle. Conversely, the RF signal is picked up from the RF waveguide by the probe at the left, and flows rightward to the diodes. Because the RF is in a quasi- TEM (suspended, microstrip-like) mode, it impinges on the diodes in an anti-parallel mode that does not couple to the waveguide mode. This isolates the LO and RF signals. This operation is similar to a cross-bar mixer used at low frequencies, except the RF signal enters through the back-short end of the waveguide rather than through the side. The RF probe also conveys the down-converted intermediate frequency (IF) signal out to an off-chip circuit board through a simple LC low-pass filter to the left as indicated. The bias is brought to the diodes through a bypass capacitor at the top.

Siegel, Peter

Broadband Sources in the 1-3 THz Range

Broadband electronically tunable sources in the terahertz range are a critical technology for enabling space-borne as well as ground-based applications. By power-combining MMIC amplifier and frequency tripler chips, we have recently demonstrated >1 mW of output power at 900 GHz. This source provides a stepping stone to enable sources in the 2-3 THz range than can sufficiently pump multi-pixel imaging arrays.

sources