Engineering Papers⌕ Search

Engineering topics

Schenkel, Thomas

Publications and source records attributed to Schenkel, Thomas.

44 records · Page 3

Evaluation of Non-Nuclear Techniques for Well Logging: Technology Evaluation

This report presents an initial review of the state-of-the-art nuclear and non-nuclear well logging methods and seeks to understand the technical and economic issues if AmBe, and potentially other isotope sources, are reduced or even eliminated in the oil-field services industry. Prior to considering alternative logging technologies, there is a definite need to open up discussions with industry regarding the feasibility and acceptability of source replacement. Industry views appear to range from those who see AmBe as vital and irreplaceable to those who believe that, with research and investment, it may be possible to transition to electronic neutron sources and employ combinations of non-nuclear technologies to acquire the desired petro-physical parameters. In one sense, the simple answer to the question as to whether petro-physical parameters can be sensed with technologies other than AmBe is probably "Yes". The challenges come when attention turns to record interpretation. The many decades of existing records form a very valuable proprietary resource, and the interpretation of subtle features contained in these records are of significant value to the oil-gas exploration community to correctly characterize a well. The demonstration of equivalence and correspondence/correlation between established and any new sensing modality, and correlations with historic records is critical to ensuring accurate data interpretation. Establishing the technical basis for such a demonstration represents a significant effort.

02 PETROLEUM↗

Carbon nanotube collimator fabrication and application

Apparatus, methods, systems and devices for fabricating individual CNT collimators. Micron size fiber coated CNT samples are synthesized with chemical vapor deposition method and then the individual CNT collimators are fabricated with focused ion beam technique. Unfocused electron beams are successfully propagated through the CNT collimators. The CNT nano-collimators are used for applications including single ion implantation and in high-energy physics, and allow rapid, reliable testing of the transmission of CNT arrays for transport of molecules.

Chow, Lee↗

Chip-Scale Nanofabrication of Single Spins and Spin Arrays in Diamond

We demonstrate a technique to nanofabricate nitrogen vacancy (NV) centers in diamond based on broad-beam nitrogen implantation through apertures in electron beam lithography resist. This method enables high-throughput nanofabrication of single NV centers on sub-100-nm length scales. Secondary ion mass spectroscopy measurements facilitate depth profiling of the implanted nitrogen to provide three-dimensional characterization of the NV center spatial distribution. Measurements of NV center coherence with on-chip coplanar waveguides suggest a pathway for incorporating this scalable nanofabrication technique in future quantum applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Single Ion Implantation and Deterministic Doping

The presence of single atoms, e.g. dopant atoms, in sub-100 nm scale electronic devices can affect the device characteristics, such as the threshold voltage of transistors, or the sub-threshold currents. Fluctuations of the number of dopant atoms thus poses a complication for transistor scaling. In a complementary view, new opportunities emerge when novel functionality can be implemented in devices deterministically doped with single atoms. The grand price of the latter might be a large scale quantum computer, where quantum bits (qubits) are encoded e.g. in the spin states of electrons and nuclei of single dopant atoms in silicon, or in color centers in diamond. Both the possible detrimental effects of dopant fluctuations and single atom device ideas motivate the development of reliable single atom doping techniques which are the subject of this chapter. Single atom doping can be approached with top down and bottom up techniques. Top down refers to the placement of dopant atoms into a more or less structured matrix environment, like a transistor in silicon. Bottom up refers to approaches to introduce single dopant atoms during the growth of the host matrix e.g. by directed self-assembly and scanning probe assisted lithography. Bottom up approaches are discussed in Chapter XYZ. Since the late 1960's, ion implantation has been a widely used technique to introduce dopant atoms into silicon and other materials in order to modify their electronic properties. It works particularly well in silicon since the damage to the crystal lattice that is induced by ion implantation can be repaired by thermal annealing. In addition, the introduced dopant atoms can be incorporated with high efficiency into lattice position in the silicon host crystal which makes them electrically active. This is not the case for e.g. diamond, which makes ion implantation doping to engineer the electrical properties of diamond, especially for n-type doping much harder then for silicon. Ion implantation is usually a highly statistical process, where high fluences of energetic ions, ranging from {approx}10{sup 9} to >10{sup 16} cm{sup -2} are implanted. For single atom device development, control over the absolute number of ions is needed and ions have to be placed with high spatial resolution. In the following sections we will discuss a series of approaches to single ion implantation with regard to single ion impact sensing and control of single ion positioning.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Device fabrication and transport measurements of FinFETs built with 28Si SOI wafers towards donor qubits in silicon

We report fabrication of transistors in a FinFET geometry using isotopically purified silicon-28 -on-insulator (28-SOI) substrates. Donor electron spin coherence in natural silicon is limited by spectral diffusion due to the residual 29Si nuclear spin bath, making isotopically enriched nuclear spin-free 28Si substrates a promising candidate for forming spin quantum bit devices. The FinFET architecture is fully compatible with single-ion implant detection for donor-based qubits, and the donor spin-state readout through electrical detection of spin resonance. We describe device processing steps and discuss results on electrical transport measurements at 0.3 K.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Using nanoscale transistors to measure single donor spins in semiconductors

We propose a technique for measuring the state of a single donor electron spin usinga field-effect transistor induced two-dimensional electron gas and electrically detected magnetic resonance techniques. The scheme is faciltated by hyperfine coupling to the donor nucleus. We analyze the potential sensitivity and outlne experimental reqiurements. Our measurement provides a single-shot, projective, and quantum non-demoltion measurement of an electron-encoded qubit state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single Ion Implantation

On the equipment needed to implant ions in silicon and other materials. More information: http://newscenter.lbl.gov/feature-stories/2008/10/22/a-toolkit-for-silicon-based-quantum-computing/

36 MATERIALS SCIENCE↗

Single Ion Implantation

On the equipment needed to implant ions in silicon and other materials. More information: http://newscenter.lbl.gov/2008/10/22/a-toolkit-for-silicon-based-quantum-computing/

ION BEAM↗