Measurement of 216Po half-life with the CUPID-0 experiment
Not Available
Engineering topics
Publications and source records attributed to Schäffner, K..
Not Available
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $\alpha -\alpha$ delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $\alpha$ decay position.
The CUPID-Mo experiment at the Laboratoire Souterrain de Modane (France) is a demonstrator for CUPID, the next-generation ton-scale cryogenic $0\nu\beta\beta$ experiment. It consists of a 4.2 kg array of 20 enriched Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers to search for the lepton number violating process of $0\nu\beta\beta$ decay in $^{100}$Mo. With more than one year of operation (2.16 kg$\times$yr of physics data), no event in the region of interest and hence no evidence for $0\nu\beta\beta$ is observed. We report a new limit on the half-life of $0\nu\beta\beta$ decay in $^{100}$Mo of $T_{1/2} > 1.5 \times 10^{24}\,$yr at 90 % C.I. The limit corresponds to an effective Majorana neutrino mass $\langle m_{\beta\beta} \rangle$ $<$ (0.3--0.5)$\,$eV, dependent on the nuclear matrix element in the light Majorana neutrino exchange interpretation.
CUPID-Mo is a cryogenic detector array designed to search for neutrinoless double-beta decay ($0\nu\beta\beta$) of $^{100}$Mo. It uses 20 scintillating $^{100}$Mo-enriched Li$_2$MoO$_4$ bolometers instrumented with Ge light detectors to perform active suppression of $\alpha$ backgrounds, drastically reducing the expected background in the $0\nu\beta\beta$ signal region. As a result, pileup events and small detector instabilities that mimic normal signals become non-negligible potential backgrounds. These types of events can in principle be eliminated based on their signal shapes, which are different from those of regular bolometric pulses. We show that a purely data-driven principal component analysis based approach is able to filter out these anomalous events, without the aid of detector response simulations.