Engineering Papers⌕ Search

Engineering topics

Scannell, Rory

Publications and source records attributed to Scannell, Rory.

Validation of prediction capability of operating space for plasma initiation in MAST-U

DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage V loop . In the experimental operating space of p 0 and V loop the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of V loop is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0 , and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of real-time density feedback control on MAST-U in L-mode

In this paper we report on the development and demonstration of density feedback control for MAST-U. Sinusoidal perturbations are used to measure the frequency response from a deuterium gas valve (actuator) to line-integrated core electron density measured by the interferometer (sensor). In the frequency range relevant for control design, only two system-identification experiments were needed to regress a first-order dynamic model. This control-oriented model informs the offline design of a proportional integral controller with the established loop-shaping controller design method. After offline verification of the controller implementation, control is demonstrated by experimentally tracking a staircase reference for the line-integrated electron density. This paper demonstrates the efficiency of controller design using system-identification and loop-shaping, providing reliable density control for MAST-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density limits as disruption forecasters for spherical tokamaks

Fusion power output from spherical tokamaks would benefit from increased confined plasma density, but there exists a limit on the density before confinement is lost and the plasma current is disrupted. This density limit has long been characterized by a simple, global Greenwald limit proportional to the plasma current and inversely proportional to the cross sectional area of the plasma. It is shown that in the database of discharges from the National Spherical Tokamak Experiment (NSTX) and Mega Ampere Spherical Tokamak (MAST) spherical tokamaks, the likelihood of disruption does increase above the Greenwald limit, and especially in the plasma current rampdown phase. The physics of the density limit has been recently theoretically explored through local criteria. Several of these are tested using the disruption event characterization and forecasting (DECAF TM ) code for their potential effectiveness as disruption warning signals. For a limited set of NSTX discharges, a local island power balance criteria was found to be less reliable, presently, than the Greenwald limit. For this work, an empirical critical edge line density and a boundary turbulent transport limit were both tested for MAST-U, which has an electron density profile measurement with high spatial resolution in the outer part of the plasma. Both were found to have similar dependencies on key plasma parameters. In a limited set of MAST-U discharges that appear to disrupt due to rising density at values under the Greenwald limit, crossing of the boundary turbulent transport limit occurred close to the time of disruption. Finally, these limits were evaluated for their potential use in real-time, and it was found that with the necessary real-time inputs and with refinement through further testing, these limits could be implemented in a real-time disruption forecasting system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗