Engineering Papers⌕ Search

Engineering topics

Sawyer, Patricia S.

Publications and source records attributed to Sawyer, Patricia S..

Electrochemical aptamer-based sensors: leveraging the sensing platform for minimally-invasive microneedle measurements and fundamental exploration of sensor biofouling dynamics

The ability to track the concentrations of specific molecules in the body in real time would significantly improve our ability to study, monitor, and respond to diseases. To achieve this, we require sensors that can withstand the complex environment inside the body. Electrochemical aptamer-based sensors are particularly promising for in vivo sensing, as they are among the only generalizable sensing technologies that can achieve real-time molecular monitoring directly in blood and the living body. In this project, we first focused on extending the application space of aptamer sensors to support minimally-invasive wearable measurements. To achieve this, we developed individually-addressable sensors with commercial off-the-shelf microneedles. We demonstrated sensor function in buffer, blood, and porcine skin (a common proxy for human skin). In addition to the applied sensing project, we also worked to improve fundamental understanding of the aptamer sensing platform and how it responds to biomolecular interferents. Specifically, we explored the interfacial dynamics of biofouling – a process impacting sensors placed in complex fluids, such as blood.

59 BASIC BIOLOGICAL SCIENCES↗

Stress Relaxation in Epoxy Thermosets via a Ferrocene-Based Amine Curing Agent

Physical stress relaxation in rubbery, thermoset polymers is limited by cross-links, which impede segmental motion and restrict relaxation to network defects, such as chain ends. In parallel, the cure shrinkage associated with thermoset polymerizations leads to the development of internal residual stress that cannot be effectively relaxed. Recent strategies have reduced or eliminated such cure stress in thermoset polymers largely by exploiting chemical relaxation processes, wherein temporary cross-links or otherwise transient bonds are incorporated into the polymer network. In this paper, we explore an alternative approach, wherein physical relaxation is enhanced by the incorporation of organometallic sandwich moieties into the backbone of the polymer network. A standard epoxy resin is cured with a diamine derivative of ferrocene and compared to conventional diamine curing agents. The ferrocene-based thermoset is clearly distinguished from the conventional materials by reduced cure stress with increasing cure temperature as well as unique stress relaxation behavior above its glass transition in the fully cured state. The relaxation experiments exhibit features characteristic of a physical relaxation process. Furthermore, the cure stress is observed to vanish precipitously upon deliberate introduction of network defects through an increasing imbalance of epoxy and amine functional groups. Finally, we postulate that these beneficial properties arise from fluxional motion of the cyclopentadienyl ligands on the polymer backbone.

36 MATERIALS SCIENCE↗

Radiation Testing of a Low Voltage Silicone Nuclear Power Plant Cable

This report summarizes the results generated in FY13 for cable insulation in support of DOE's Light Water Reactor Sustainability (LWRS) Program, in collaboration with the US-Argentine Binational Energy Working Group (BEWG). A silicone (SiR) cable, which was stored in benign conditions for ~30 years, was obtained from Comision Nacional de Energia Atomica (CNEA) in Argentina. Physical property testing was performed on the as-received cable. This cable was artificially aged to assess behavior with additional analysis. SNL observed appreciable tensile elongation values for all cable insulations received, indicative of good mechanical performance. Of particular note, the work presented here provides correlations between measured tensile elongation and other physical properties that may be potentially leveraged as a form of condition monitoring (CM) for actual service cables. It is recognized at this point that the polymer aging community is still lacking the number and types of field returned materials that are desired, but SNL—along with the help of others—is continuing to work towards that goal. This work is an initial study that should be complimented with location-mapping of environmental conditions of CNEA plant conditions (dose and temperature) as well as retrieval, analysis, and comparison with in-service cables.

White II, Gregory Von↗