Commissioning of the SLAC Linac Coherent Light Source II electron source
Not Available
Engineering topics
Publications and source records attributed to Sannibale, F..
Not Available
Explore the source record for details and available documents.
Explore the source record for details and available documents.
High brightness, high repetition rate electron beams are key components for optimizing the performance of next generation scientific instruments, such as MHz-class X-ray Free Electron Laser (XFEL) and Ultra-fast Electron Diffraction/Microscopy (UED/UEM). In the Advanced Photo-injector EXperiment (APEX)at Berkeley Lab, a photoelectron gun based on a 185.7 MHz normal conducting re-entrant RF cavity, has been proven to be a feasible solution to provide high brightness, high repetition rate electron beam for both XFEL and UED/UEM. Based on the success of APEX, a new electron gun system, named APEX2, has been under development to further improve the electron beam brightness. For APEX2, we have designed a new 162.5 MHz two-cell photoelectron gun and achieved a significant increase on the cathode launching field and the beam exit energy. For a fixed charge per bunch, these improvements will allow for the emittance reduction and hence to an increased beam brightness. The design of APEX2 gun cavity is a complex problem with multiple design goals and restrictions, some even competing each other. In conclusion, for a systematic and comprehensive search for the optimized cavity geometry, we have developed and implemented a novel optimization method based on the Multi-Objective Genetic Algorithm (MOGA).
Explore the source record for details and available documents.
The very-high-frequency gun (VHF-Gun) is a new concept photo-injector developed and built at the Lawrence Berkeley National Laboratory (LBNL) for generating high-brightness electron beams capable of driving X-ray free electron lasers (FELs) at MHz-class repetition rates. The gun that purposely uses established and mature radiofrequency and mechanical technologies has demonstrated over the last many years the capability of reliably operating in continuous wave mode at the design accelerating fields and required vacuum and mechanical performance. The conclusions of VHF-Gun technology demonstration were reported elsewhere [Sannibale et al., Phys. Rev. Spec. Top.-Accel. Beams 15, 103501 (2012)]; here in this work, we provide and analyze examples of the experimental results of the first high-brightness beam tests performed at the Advanced Photo-injector EXperiment test facility at LBNL that demonstrated the gun capability of delivering the beam quality required for driving high repetition rate X-ray FELs.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Not Available
Not Available
A high repetition rate, MHz-class, high-brightness electron source is a key element in future high-repetition-rate x-ray free electron laser-based light sources. The VHF-gun, a novel low frequency radio-frequency gun, is the Lawrence Berkeley National Laboratory (LBNL) response to that need. The gun design is based on a normal conducting, single cell cavity resonating at 186 MHz in the VHF band and capable of continuous wave operation while still delivering the high accelerating fields at the cathode required for the high brightness performance. The VHF-gun was fabricated and successfully commissioned in the framework of the Advanced Photo-injector EXperiment, an injector built at LBNL to demonstrate the capability of the gun to deliver the required beam quality. In conclusion, the basis for the selection of the VHF-gun technology, novel design features, and fabrication techniques are described.
Not Available
The Next Generation Light Source will deliver high (MHz) repetition rate electron beams to an array of free electron lasers. Because of the significant average current in such a facility, effective beam collimation is extremely important to minimize radiation damage to undulators, prevent quenches of superconducting cavities, limit dose rates outside of the accelerator tunnel and prevent equipment damage. This paper describes the early conceptual design of a collimation system, as well as initial results of simulations to test its effectiveness.