Engineering Papers⌕ Search

Engineering topics

Sangiorgio, Samuele

Publications and source records attributed to Sangiorgio, Samuele.

High yield, large-scale synthesis of calcium-based microporous metal-organic framework and examination of the long-term stability for xenon adsorption applications

Here, scale-up synthesis of calcium-based microporous metal-organic framework (SBMOF-1) up to ~400 g in a batch with a yield of >90 % was achieved by a solvothermal reaction of sulfonyldibenzoic acid (SDB) with an excess of calcium chloride. Here, we observed that recrystallization of unreacted SDB at a solvothermal condition caused a moderate reaction yield (40–50 %) at the reference condition of $C_{CaCl_2}$/$C_{SDB}$=1 and $C_{SDB}$/$C_{SDB(ref)}$=1. Simply adding more reagents to the reactor did not increase the mass of product formed per unit volume due to a more pronounced loss of the yield at those conditions. By simultaneously changing the molar ratio of CaCl 2 to SDB, $C_{CaCl_2}$/$C_{SDB}$, and the molar concentration of the SDB reagent, $C_{SDB}$/$C_{SDB(ref)}$, we explored %yield of the reaction. Interestingly, a linear improvement in the yield was observed from 21% (at $C_{CaCl_2}$/$C_{SDB}$=0.5) up to 78% (at $C_{CaCl_2}$/$C_{SDB}$=6) at a fixed ratio of $C_{SDB}$/$C_{SDB(ref)}$=2 and the yield leveled off after further addition. Unlike those at $C_{CaCl_2}$/$C_{SDB}$=1, the yields at a high CaCl 2 excess continued to improve with increasing the $C_{SDB}$/$C_{SDB(ref)}$. When a large pressure vessel (2500 mL EtOH, $C_{CaCl_2}$/$C_{SDB}$=6, $C_{SDB}$/$C_{SDB(ref)}$=8) was used, about 415 g of SBMOF-1 with a yield of 92.3% was produced, indicating 16 × the space yield improvement. The ability to synthesize SBMOF-1 on a large scale allowed us to examine the long-term stability of SBMOF-1 for almost 200 days in the presence of varying levels of relative humidity.

36 MATERIALS SCIENCE↗

Semi-empirical simulation of in-motion radiation detection systems

The Replicative Assessment of Spectroscopic Equipment (RASE) is an open-source software that uses experimental data as the basis to simulate the response of commercial radiation detectors to sources in various situations, particularly in the context of nuclear security and safeguards applications. Dynamic RASE introduces the capability to simulate scenarios where sources and detector are in relative motion. Position-dependent experimentally acquired gamma spectra are ingested by Dynamic RASE to build maps that describe the detector response over all space. These response maps are used to replicate the time-dependent energy spectra collected as sources move on a path near the detector. Here, a Gaussian process is used to build each map, incorporating a novel kernel adapted to the special case of radiation detection. The approach has been validated against experimental data acquired using a NaI-based detector for 137 Cs and 54 Mn sources. The capability to create accurate simulations using either long-dwell static measurements or dynamic pass-by measurements as source data has been demonstrated. Quantitative relative performance, benefits, and shortcomings are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Replicative Assessment of Spectroscopic Equipment v3.0

The Replicative Assessment of Spectrometric Equipment (RASE) is a software for evaluating the performance of radiation detectors and isotope identification algorithms. It uses a semi-empirical approach to rapidly generate synthetic spectra and inject into detector's software to obtain nuclide identification response. RASE facilitates studies of spectroscopic device performance and a quantitative assessment of its capabilities to correctly distinguish and identify isotopes of interest in realistic scenarios

Sangiorgio, Samuele↗

Replicative Assessment of Spectroscopic Equipment

The Replicative Assessment of Spectrometric Equipment (RASE) is a software for evaluating the performance of radiation detectors and isotope identification algorithms. It uses a semi-empirical approach to rapidly generate synthetic spectra and inject into detector's software to obtain nuclide identification response. RASE facilitates studies of spectroscopic device performance and a quantitative assessment of its capabilities to correctly distinguish and identify isotopes of interest in realistic scenarios.

Chavez, JosephR.↗

Applying a Template of Expected Uncertainties to Updating 239 Pu(n,f) Cross-section Covariances in the Neutron Data Standards Database

Templates of uncertainties expected in specific measurement types were recently developed. One aim of these templates is to help evaluators in identifying (1) missing or suspiciously low uncertainties and (2) missing correlations between uncertainties of the same and different experiments, when estimating covariances for experimental data employed in their evaluations. These templates also provide realistic estimates of standard deviations and correlations for a particular uncertainty source and measurement type that can be used by evaluators in situations where they are not supplied by the experimenters. This information allows for a more comprehensive uncertainty analysis across all measurements considered in an evaluation and, thus, more realistic evaluated covariances. Here, in this work, we extend a template that is applicable to uncertainties expected in neutron-induced fission, (n,f), cross-section measurements. It is applied to improving covariances of 239 Pu(n,f) cross-section measurements in the database underlying the Neutron Data Standards evaluations. This particular example was chosen since this evaluation is primarily based on experimental information. Also, some uncertainties of individual 239 Pu(n,f) cross-section experiments in this database were suspected to be underestimated. The evaluated uncertainties obtained after updating the covariances in the database by means of the template indeed do increase compared to their original values. Even more importantly, the evaluated mean values change noticeably. These modified cross sections impact application calculations significantly, as is demonstrated by employing them in simulations of the effective neutron multiplication factor for a few selected critical assemblies. However, this updated evaluated 239 Pu(n,f) cross section should not be interpreted as the final one that should replace values of the current Neutron Data Standards project. Evaluations for the Neutron Data Standards of the 239 Pu(n,f) cross section must be linked to many other observables included in the associated database, most notably to cross sections for 235 U(n,f), but also to those for 10 B(n, α ), 6 Li(n,t), 238 U(n,f), and 238 U(n, γ ), because of included measurements of the 239 Pu(n,f) cross section that appear as ratios to these reactions. Some of these other reactions are correlated to further observables in the database. Hence, updating uncertainties of data sets of any of these observables can potentially impact the 239 Pu(n,f) cross section. Uncertainties for all measurements of these linked physical observables have to be updated before a comprehensive evaluation of the 239 Pu(n,f) cross section and its corresponding uncertainties can be provided.

239Pu Neutron-induced fission cross-section↗