Engineering Papers⌕ Search

Engineering topics

Sanchez, Rene G.

Publications and source records attributed to Sanchez, Rene G..

At least 19 records

The Jupiter High-240 Experiment

The Jupiter High-240 experiment was performed in May of 2019 by researchers from Los Alamos National Laboratory (LANL) at the National Criticality Experiments Research Center (NCERC) in the Device Assembly Facility (DAF) located at the Nevada National Security Site (NNSS). This experiment has previously been mentioned briefly in prior publication related to a collaborative effort with the Japan Atomic Energy Agency (JAEA) to assess lead void coefficients of reactivity in uranium- and plutonium-fueled systems with lead. This series of experiments supports JAEA’s research into the development of an accelerator driven transmutation system for spent nuclear fuel. The Jupiter High-240 experiment built upon the previous Jupiter experiment by incorporating plutonium fuel plates with higher 240 Pu content. Efforts to formally benchmark the original Jupiter experiment have continued for inclusion in the benchmark handbook of the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Whereas there is much similarity between the two Jupiter experiments, there is a desire to also evaluate and benchmark this second experiment to further contribute towards the availability of lead-sensitive benchmarks. The components utilized in these two experiments have also been used to perform other subcritical and Rossi-α measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The National Criticality Experiments Research Center and its role in support of advanced reactor design

The National Criticality Experiments Research Center (NCERC) located at the Nevada National Security Site (NNSS) in the Device Assembly Facility (DAF) and operated by Los Alamos National Laboratory (LANL) is the only general purpose critical experiments facility in the United States. Experiments from subcritical to critical and above prompt critical are carried out at NCERC on a regular basis. In recent years, NCERC has become more involved in experiments related to nuclear energy, including the Kilopower/KRUSTY demonstration and the recent Hypatia experiment. Multiple nuclear energy related projects are currently ongoing at NCERC. This paper discusses NCERC’s role in advanced reactor design and how that role may change in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rossi-alpha Analysis of Thermal/Epithermal eXperiments Optimized for Polyethylene Thermal Neutron Scattering

Accurate nuclear data is the foundation for predictive simulations and design of new experimental in the nuclear community. The criticality safety community has particular interest in benchmarking assemblies with thermal neutron data. To address such needs the Nuclear Criticality Safety Program (NCSP) funded the Thermal/Epithermal eXperiments (TEX) campaigns that were to be completed between Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL). Specifically, analysis of plutonium with a thermal neutron spectrum expands on previous work to help validate thermal scattering law data, which can have larger impacts in thermal applications. The first of these experiments were successfully conducted in 2018, but this paper will focus on the 2021 measurement focused on investigating the the thermal scattering law (TSL) for polyethylene. These experiments were successfully conducted at the National Criticality Experiments Research Center (NCERC) using the Planet vertical lift critical assembly machine. Polethylene plates were layered with trays of Zero Power Physics Reactor (ZPPR) 24 plates in a 12" by 12" square. The ZPPR plates were 2" by 3" by 0.125" bearing weapons grade plutonium. The polyethylene moderator was either 2" or 1.6875" thick. This work builds on the Rossi-alpha calculations done by McKenzie et al. for the same detector-assembly system and will only focus on the Rossi-alpha neutron noise method. This work will aim to further validate the results of the experiment through a novel neutron noise python package. Following similar methodology to the previous analysis, analysis of TEX evaluated the prompt neutron decay constant at delayed critical, $α_{DC}$ using Rossi-alpha for different polyethylene moderator thicknesses. These results will help improve understanding of TSL in critical experiments. Alpha (α), is the prompt neutron decay constant of the measured system and allows for the evaluation of a systems propensity to sustain fission chains via prompt neutrons. The single value description of the assemblies allow for comparison between experiments regardless of composition, geometry, and reflectors/moderators. Rossi-alpha measurements were performed on the polyethylene moderated TEX experiments to estimate $α_{DC}$.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hybrid Particle Swarm-Interpolation Algorithm for Improved Critical Experiment Design

The typical goal of designing a critical experiment is twofold: a system that is both critical and optimized for some other value. This value could be an energy-integrated sensitivity, percent fissions in a certain energy range, or some other value that can be calculated by a transport code. By simulating different combinations of reflector, moderator, and fuel thicknesses a designer can identify such a desirable configuration. The domain of all possible combinations of these thicknesses is referred to as the experiment search space. As more dimensions are added, the search space increases in size exponentially. For a three-dimensional case, which includes three thickness values between zero and ten centimeters to the nearest tenth of a millimeter, a total of 1,000 3 , configurations exists. Rather than check each configuration individually, which would be extremely computationally expensive, it has been shown to be more efficient to use a conventional particle swarm optimization (PSO) algorithm to identify critical and optimal configurations. This work presents the theory and implementation of a novel hybrid PSO interpolation algorithm to perform these optimizations faster than a conventional PSO algorithm. To demonstrate this, an example optimization will be carried out by the conventional and hybrid PSO algorithms and their performances will be compared.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress Update on the MUSIC Critical Benchmark

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values. The large range of multiplications allows researchers to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. The critical configurations were the extreme end of the multiplication range in MUSIC configurations. A critical benchmark in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook is planned to help further validate nuclear data. Even though there are many benchmarks focusing on the fast spectrum for highly-enriched uranium, an additional benchmark that is well documented and up to the modern standard of the handbook would be a welcome addition. Given that there are no other materials such as moderators or significant reflectors, and its similarity to Lady Godiva, it is possible that this could be very useful for validation of 235 U nuclear data in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distribution of Neutrons in a Cold Lucite Moderator

A series of experiments was performed in 2010 to study the behavior of neutrons in a cold Lucite moderator. The diffusion of neutrons in a cold moderator is described as a two-step process. In the first step, the fast neutrons produced by a neutron source collide with the nuclei of Lucite, losing energy until they reach thermal energies. In the second step, the thermal neutrons continue to diffuse without any significant loss of energy until they are absorbed or leak out of the system. However, because the Lucite moderator is at low temperature, there is less up scattering in the neutron energy compared to a Lucite moderator at room temperature. Experiments were performed to study the behavior of neutrons and their distribution in a cold Lucite moderator and their results compared to simulations. Based on these measurements, an estimation of the absorption cross section at -78.5 °C yielded a value of 0.54 barns ± 0.02 barns.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-α Measurements on a System Consisting of Weapons Grade Plutonium Moderated by Polyethylene

A critical experiment was performed on the Planet assembly to provide nuclear data in a thermal neutron spectrum, in particular to provide experimental data to help validate thermal scattering laws for polyethylene. The fuel consisted of layers of weapons grade plutonium plates that were moderated and reflected by various thicknesses of high density polyethylene. Rossi-α measurements were performed on a slightly modified configuration from the configuration used for the critical measurements. The Rossi-α measurement techniques are discussed and results are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Particle Swarm Optimization Algorithm for Critical Experiment Design

Nuclear criticality experiments are used to validate nuclear cross section data used by simulation software. This is typically achieved by designing a critical system with a high sensitivity to a certain material’s cross section. Once the experiment has been carried out, a high fidelity model of the system is developed into a benchmark. When this benchmark model is simulated by a transport code, some of the difference between the experimental and computational effective neutron multiplication factor can be attributed to inaccurate nuclear data. Nuclear data evaluators then can make adjustments accordingly to improve cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 488: MUSiC Accomplishments and Goals [Slides]

IER-488: Measurement of Uranium Subcritical and Critical (MUSiC) consists of measurements of bare, HEU systems covering a large range of reactivities. Multiple detector systems and analysis methods are being used to obtain detector-independent results. Massive amounts of data and information available. Substantial analysis has been completed for both critical and subcritical configurations. Work in progress is largely novel research and will result in several conference proceedings, journal publications, and a subcritical benchmark. There is still a large amount of data that has not been analyzed and much more to come from the analysis of the Measurements of Uranium Subcritical and Critical.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rossi-alpha Analysis of CURIE Experiment

Critical assembly measurement and operations are crucial to the development of benchmark data to support research into criticality safety, radiation-detection development, and the overall application of nuclear technologies. Accurate nuclear data are needed for accurate predictive simulations, and validation using critical experiments is an important part of the nuclear data pipeline. The accuracy of nuclear data are improved using more robust and targeted measurements. In particular, the intermediate energy range of uranium is of great interest. LANL has successfully performed the Zeus series of experiments on the Comet assembly to investigate the intermediate energy range for HEU with various moderators. A successor to these experiments is the benchmark for the Critical Unresolved Region Integral Experiment (CURIE), designed to be sensitive to the unresolved resonance region (URR). This experiment is designed using polytetrafluoroethylene, more commonly known as Teflon, moderators. The CURIE experiment was successfully conducted at the National Criticality Experiments Research Center (NCERC). The Rossi-alpha method was used to evaluate the propensity of the CURIE configurations to sustain fission chains by estimating the prompt neutron decay constant α. This work evaluates the α at delayed critical using Rossi-alpha for different Teflon moderator thicknesses in the CURIE experiment. These results will help improve understanding of the CURIE benchmark experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty Analysis for a Criticality Benchmark [Slides]

This presentation discusses how KRUSTY was analyzed with LANL’s MCNP neutron transport code, Monte Carlo N-Particle. In the Monte Carlo method, neutrons are born in fission events and fly around the geometry having events (e.g., scatter, capture, fission, escape) according to the natural probabilities. “Natural probabilities” are given as neutron cross sections , which are measured and evaluated nuclear data. One of the goals of the benchmark project is to improve the nuclear cross sections (and the codes that use them). In this work, the response of interest is called k eff , which describes the neutron multiplication in a near critical system. Like most quantities, k eff is not measured directly; it is only inferred. In summation, MCNP results for k eff matched the measurements extremely well. The evaluated uncertainties are asymmetric and smaller than 0.00100 (e.g., + 0.00080 / – 0.00062). The largest uncertainties are due to alignment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical Unresolved Region Integral Experiment Execution

Integral Experiments are a key aspect of validating nuclear data behavior and simulation capabilities. Further, integral experiments are the earliest form of validation of equations and codes. They have been used extensively since the 1940s. Today, simulation and predictive capabilities have improved greatly from 75 years ago, but nonetheless, integral experiments are still needed. As simulation capabilities improve, their uncertainties get much smaller. The current focus of many new experiments is understanding the intermediate energy range. The intermediate energy range does not have a wide application space and it can be challenging to design experiments that are sensitive to neutron energies in this region. The Zeus experiments evaluated highly enriched uranium (HEU) in the intermediate energy region. Building on the success and knowledge gained from the Zeus experiments, the Critical Unresolved Region Integral Experiment (CURIE) experiments were designed to evaluate HEU in the narrower unresolved resonance region (URR). These experiments were executed during June and July 2020 at the National Criticality Experiments Research Center (NCERC). The National Criticality Experiments Research Center (NCERC), operated by Los Alamos National Laboratory, is the only general purpose critical experiments facility in the United States of America. NCERC regularly designs and executes critical experiments and other measurements useful to a wide variety of fields including nuclear criticality safety, commercial nuclear energy, nonproliferation, and nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation and Independent Uncertainty Analysis of the MIX-SOL-THERM-003 ICSBEP Benchmark

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) was started in 1992 by the United States Department of Energy and later in 1995 became an international project with contributions from 22 countries. The project is now organized by the OECD (Organisation for Economic Co-operation and Development) Nuclear Energy Agency (NEA). In its most recent iteration, the ICSBEP handbook contains over five thousand evaluations of critical, near-critical, and subcritical experiments conducted in facilities all around the world. These benchmarks serve as valuable information for criticality safety engineers who can use them to validate calculation techniques and establish minimum subcritical margins for operations with fissionable materials. The benchmarks in the handbook are categorized by their fissile material composition, material form (oxide, solution, or metal), and fission energy spectra. This is especially useful for those looking for benchmarks similar to a system they are working on to compare methods and identify trends. The ICSBEP Handbook Uncertainty Guide is document outlining recommended practices and methods for determining uncertainties in these benchmarks. Quantifying these uncertainties thoroughly is crucial as it allows a higher degree of confidence that data used from them is valid and relevant. The guide stresses the importance of a thorough and well documented uncertainty analysis when evaluating an experiment. All measured values of a system, whether they be dimensions or material compositions, have a certain amount of uncertainty associated with them and can be analyzed one by one to determine their effects on the system. Many evaluated benchmarks in the handbook present this in detail, however some do not, mostly earlier evaluations performed in the 1990’s and early 2000’s. Recently at Los Alamos National Laboratory (LANL), the Nuclear Criticality Safety Division (NCSD) of LANL has been validating MCNP6.2 ® input files of criticality benchmarks for use by Whisper, a criticality safety code developed at LANL. This effort is also part of the OECD NEA Working Party on International Nuclear Data Evaluation Co-operation (WPEC) Subgroup 45, also known as Validation of Nuclear Data Libraries (VaNDaL). The goal of VaNDaL is to compile a set of validated simulation inputs for use in validating nuclear data and simulation codes. As part of these efforts, one of the benchmarks reviewed was the MIX SOL-THERM-003 ICSBEP benchmark. This paper provides an independent uncertainty analysis of this benchmark experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results of the KRUSTY Warm Critical Experiments

The Kilowatt Reactor Using Stirling TechnologY (KRUSTY) was a prototypic nuclear-powered test of a 5-kW(thermal) Kilopower space reactor. This paper presents results from the KRUSTY warm critical experiments, which were completed prior to the final system test. The first set of criticals comprised cold or zero-power criticals; i.e., the core was not heated by fission power. These were followed by three warm criticals, where fission power heated the core to 200°C, 300°C, and 450°C, respectively. These criticals provided the data, confidence, and regulatory framework that were needed to proceed with the KRUSTY nuclear system test. The criticals also provided valuable data for the benchmarking of codes applicable to all nuclear systems. Finally, a comparison of KRUSTY results to pretest predictions is provided, and overall, the models matched the experimental results very closely.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Results of the KRUSTY Nuclear System Test

The Kilowatt Reactor Using Stirling TechnologY (KRUSTY) was a prototypic nuclear-powered test of a 5-kW(thermal) Kilopower space reactor. This paper presents results from the KRUSTY nuclear system test, which operated the power system at various temperatures and power levels for 28 consecutive hours. The testing showed that the system operated as expected and that the reactor is highly tolerant of possible failure conditions and transients. The key feature demonstrated was the ability of the reactor to load-follow the demand of the power conversion system. The thermal power of the test ranged from 1.5 to 5.0 kW(thermal), with a fuel temperature up to 880°C. Each 80-W(electric)–rated Stirling converter produced ~90 W(electric) at a component efficiency of ~35% and an overall system efficiency of ~25%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IER 153: Measure the Fission Neutron Spectrum Shape Using Threshold Activation Detectors - CEDT Phase-1 Preliminary Design

The critical assembly chosen to perform these irradiation experiments is the Planet assembly. The purpose of this experiment is to determine more precisely the fission neutron spectrum. According to recent measurements of neutron cross section data performed in Russia, Hungary, and some other countries, the data suggest that ENDF/B fission neutron spectra has too few neutrons emitted below 1 MeV. In addition, measurements at TA-18 Los Alamos Critical Experiment Facility (LACEF) suggest that the fission spectrum may be too low (between 10-30%) for energies above 10 MeV. These proposed deficiencies in the tails of the fission spectrum may have repercussions in our mission applications related to nuclear energy and global security and need to be resolved. To measure the fission neutron spectrum, threshold activation foils will be used in the center of a highly enriched uranium assembly that will be assembled on the Planet vertical assembly machine.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗