Engineering Papers⌕ Search

Engineering topics

Sanchez, Andres

Publications and source records attributed to Sanchez, Andres.

Extended use of face masks during the COVID-19 pandemic - Thermal conditioning and spray-on surface disinfection

The current COVID-19 pandemic has resulted in globally constrained supplies for face masks and personal protective equipment (PPE). Production capacity is limited in many countries and the future course of the pandemic will likely continue with shortages for high quality masks and PPE in the foreseeable future. Therefore, expectations are that mask reuse, extended wear and similar approaches will enhance the availability of personal protective measures. Repeated thermal disinfection could be an important option and likely easier implemented in some situations, at least on the small scale, than UV illumination, irradiation or hydrogen peroxide vapor exposure. In this paper, an overview on thermal responses and ongoing filtration performance of multiple face mask types is provided. Most masks have adequate material properties to survive a few cycles (i.e. 30 min disinfection steps) of thermal exposure in the 75°C regime. Some are more easily affected, as seen by the fusing of plastic liner or warping, given that preferred conditioning temperatures are near the softening point for some of the plastics and fibers used in these masks. Hence adequate temperature control is equally important. As guidance, disinfectants sprayed via dilute solutions maintain a surface presence over extended time at 25 and 37°C. Some spray-on alcohol-based solutions containing disinfectants were gently applied to the top surface of masks. Neither moderate thermal aging (less than 24 h at 80 and 95°C) nor gentle application of surface disinfectant sprays resulted in measurable loss of mask filter performance. Subject to bio-medical concurrence (additional checks for virus kill efficiency) and the use of low risk non-toxic disinfectants, such strategies, either individually or combined, by offering additional anti-viral properties or short term refreshing, may complement reuse options of professional masks or the now ubiquitous custom-made face masks with their often unknown filtration effectiveness.

36 MATERIALS SCIENCE↗

Environmental Persistence of Biological Aerosols in Outdoor and Simulated Environments

The fate of biological aerosols in the atmosphere depends on the unique and dynamic environmental conditions it is exposed to during transport. There exist many processes that can impact the effectiveness of an aerosol release, and its fate in the environment. Aerosol properties may be modified if biological particles that are released into the atmosphere interact with free radicals, volatile organic compounds(VOC), semi-volatile organic compounds, and inorganic gasphase compounds, such as NOx and SOx. Meteorological conditions such as ultraviolet(UV)- light, relative humidity(RH), and temperature have also been shown to affect biological aerosols, with interactions dependent on both the organism and aerosol's chemical make-up. Oxidation or secondary-organic aerosol (SOA) formations on the particle can also lead to changes in surface proteins and extra-cellular nucleic acids that may agent detection technologies, at a different rate than the infectivity of the agents. Once modified, agents may then be transported via many atmospheric processes such as deposition or incorporation into cloud condensation nuclei(CCN). Although these processes are known, it is unclear what the resulting form and potency ofthe bioaerosol may be after alteration by these processes.

54 ENVIRONMENTAL SCIENCES↗

Enhanced Micellar Catalysis LDRD.

The primary goals of the Enhanced Micellar Catalysis project were to gain an understanding of the micellar environment of DF-200, or similar liquid CBW surfactant-based decontaminants, as well as characterize the aerosolized DF-200 droplet distribution and droplet chemistry under baseline ITW rotary atomization conditions. Micellar characterization of limited surfactant solutions was performed externally through the collection and measurement of Small Angle X-Ray Scattering (SAXS) images and Cryo-Transmission Electron Microscopy (cryo-TEM) images. Micellar characterization was performed externally at the University of Minnesota s Characterization Facility Center, and at the Argonne National Laboratory Advanced Photon Source facility. A micellar diffusion study was conducted internally at Sandia to measure diffusion constants of surfactants over a concentration range, to estimate the effective micelle diameter, to determine the impact of individual components to the micellar environment in solution, and the impact of combined components to surfactant phase behavior. Aerosolized DF-200 sprays were characterized for particle size and distribution and limited chemical composition. Evaporation rates of aerosolized DF-200 sprays were estimated under a set of baseline ITW nozzle test system parameters.

Betty, Rita G.↗