Engineering Papers⌕ Search

Engineering topics

San Martin, Luis

Publications and source records attributed to San Martin, Luis.

Computational prediction of dielectric breakdown strength of a transformer paper in oil with uncertainty quantification

The determination of the dielectric breakdown strengths of microstructurally heterogeneous materials has been a primarily experimental endeavor. We report the development of a microstructure-level model for computationally predicting the breakdown strength and analyzing the interactions between electromagnetic pulses (EMP) and the constituents in a composite of cellulose-based paper and mineral oil found in electrical transformers. The model allows explicit simulation of the material breakdown process by tracking the transition of dielectric constituents from non-conductive to conductive states. The focus is on the electric fields induced in the materials and the overall conditions for dielectric breakdown (defined as the onset of avalanche) caused by the electric field induced in the composite. Responses to three distinct pulse shapes, i.e., Steep Front (SF), Lightning (L), and AC with spectra spanning 60–9 × 105 Hz are considered. It is found that the breakdown strength of the material is significantly affected by microstructure heterogeneities, the spatial variations of the constituent properties, and the pulse shapes. A probabilistic characterization of the breakdown strength is computationally obtained and compared with experimental measurements. Although one particular material is analyzed, the model and approach are applicable to other heterogeneous materials as well.

breakdowns↗

Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables

Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Penetration Bounds For Azimuthal Slot On Infinite Cylinder With Finite Length Backing Cylindrical Cavity

We examine coupling into azimuthal slots on an infinite cylinder with a infinite length interior cavity operating both at the fundamental cavity modal frequencies, with small slots and a resonant slot, as well as higher frequencies. The coupling model considers both radiation on an infinite cylindrical exterior as well as a half space approximation. Bounding calculations based on maximum slot power reception and interior power balance are also discussed in detail and compared with the prior calculations. For higher frequencies limitations on matching are imposed by restricting the loads ability to shift the slot operation to the nearest slot resonance; this is done in combination with maximizing the power reception as a function of angle of incidence. Finally, slot power mismatch based on limited cavity load quality factor is considered below the first slot resonance.

42 ENGINEERING↗

Estimation of the Attenuation Caused by Power Line Towers on an E1-HEMP Induced Excitation

In a transmission line, the coupling between a line and a tower above ground is evaluated when the excitation is an E1 high-altitude electromagnetic pulse (HEMP). The model focuses on capturing correctly the effect of the coupling on the peak of the HEMP induced current that propagates along the line. This assessment is necessary to accurately estimate the effect of the excitation on the systems and components of the power grid. This analysis is a step towards a quantitative evaluation of HEMP excitation on the power grid. The results obtained indicate that the effect can be significant, especially for lines heights of 20 meters or more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic Pulse – Resilient Electric Grid for National Security: Research Program Executive Summary

Sandia National Laboratories sponsored a three-year internally funded Laboratory Directed Research and Development (LDRD) effort to investigate the vulnerabilities and mitigations of a high-altitude electromagnetic pulse (HEMP) on the electric power grid. The research was focused on understanding the vulnerabilities and potential mitigations for components and systems at the high voltage transmission level. Results from the research included a broad array of subtopics, covered in twenty-three reports and papers, and which are highlighted in this executive summary report. These subtopics include high altitude electromagnetic pulse (HEMP) characterization, HEMP coupling analysis, system-wide effects, and mitigating technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗