Engineering Papers⌕ Search

Engineering topics

Saminathan, S

Publications and source records attributed to Saminathan, S.

SU-F-T-05: Dosimetric Evaluation and Validation of Newlydeveloped Well Chamber for Use in the Calibration of Brachytherapy Sources

Purpose: To evaluate the dosimetric characteristics of newly developed well type ionization chamber and to validate the results with the commercially available calibrated well chambers that are being used for the calibration of brachytherapy sources. Methods: The newly developed well type ionization chamber (BDS 1000) has been designed for the convenient use in brachytherapy which is open to atmospheric condition. The chamber has a volume of 240 cm3 and weight of 2.5 Kg. The calibration of the radioactive source with activities from 0.01 mCi to 20 Ci can be carried out using this chamber. The dosimetric parameters such as leakage current, stability, scattering effect, ion collection efficiency, reference air kerma rate and nominal response with energy were carried out with the BDS 1000 well type ion chamber. The evaluated dosimetric characteristics of BDS1000 well chamber were validated with two other commercially available well chambers (HDR 1000 plus and BTC/3007). Results: The measured leakage current observed was negligible for the newly developed BDS 1000 well type ion chamber. The ion collection efficiency was close to 1 and the response of the chamber was found to be very stable. The determined sweet spot was at 42 mm from bottom of the chamber insert. The reference air kerma rate was found to be 4.634 × 105 Gym2hr-1A-1 for the BDS 1000 well chamber. The overall dosimetric characteristics of BDS 1000 well chamber was in good agreement with the dosimetric properties of other two well chambers. Conclusion: The dosimetric study shows that the newly developed BDS 1000 well type ionization chamber is high sensitive and reliable chamber for reference air kerma strength calibration. The results obtained confirm that this chamber can be used for the calibration of HDR and LDR brachytherapy sources.

07 ISOTOPE AND RADIATION SOURCES↗

Study of ion beam extraction and transport from an electron cyclotron resonance ion source

We have started an experimental and theoretical program to better understand the extraction and transport of intense multiply charged ion beams from an electron cyclotron resonance ion source (ECRIS). In this paper we present the first results of this program concerning a simple, monocomponent He{sup +} beam extracted from an ECRIS. We have calculated the ion trajectories starting from the ECRIS plasma electrode up to the image plane of the analyzing magnet taking into account space-charge effects and fringe fields. The initial phase-space distribution of the He{sup +} beam at the extraction aperture has been calculated with a particle-in-cell code. To check the simulations we have measured beam profiles with a viewing screen both before and after the analyzing magnet. In addition also measurements with a pepperpot emittance meter located behind the analyzing magnet have been performed. We find good agreement between these measurements and simulations showing that (i) there is a significant compensation of the space charge and that (ii) our analyzing magnet causes a severe increase in effective beam emittance.

43 PARTICLE ACCELERATORS↗

Ion source development at KVI

Ion source development at KVI is focused on increasing the beam intensity from the electron cyclotron resonance ion source injector and optimizing the beam transport and injection into the superconducting AGOR cyclotron. We describe several modifications that have resulted in a significant performance increase of the ion source. We also present the first results of ion transport simulations that have been performed to better understand beam losses in the extraction region and in the low-energy beam transport system. Finally, a new emittance meter based on a combination of the pepperpot and scanning techniques will be described, which will be used to benchmark the simulation studies of ion extraction and transport in detail.

43 PARTICLE ACCELERATORS↗