Postclosure Transient Criticality Analysis for a Dual-Purpose Canister.
Abstract not provided.
Engineering topics
Publications and source records attributed to Salazar, III, Alex.
Abstract not provided.
A key objective of the United States Department of Energy’s (DOE) Office of Nuclear Energy’s Spent Fuel and Waste Science and Technology (SFWST) Campaign is to better understand the technical basis, risks, and uncertainty associated with the safe and secure disposition of spent nuclear fuel (SNF) and high-level radioactive waste. Commercial nuclear power generation in the United States has resulted in thousands of metric tons of SNF, the disposal of which is the responsibility of the DOE (Nuclear Waste Policy Act of 1982, as amended). Any repository licensed to dispose of SNF must meet requirements regarding the long-term performance of that repository. For an evaluation of the long-term performance of the repository, one of the events that may need to be considered is the SNF achieving a critical configuration during the postclosure period. Of particular interest is the potential behavior of SNF in dualpurpose canisters (DPCs), which are currently licensed and being used to store and transport SNF but were not designed for permanent geologic disposal.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
The purpose of this report is to provide updates on the experimental components, methodology, and instrumentation under development for use in advanced studies of realistic drying operations conducted on surrogate spent nuclear fuel. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. Water remaining in canisters upon completion of drying procedures can lead to cladding corrosion, embrittlement, and breaching, as well as fuel degradation. Additional information is needed on the drying process efficacy to help evaluate the potential impacts of water retention on extended longterm dry storage. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates additional, well-designed investigations. Smaller-scale tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report describes the implementation of moisture monitoring equipment on a pressurized, submersible system employing a single waterproof, electrically heated spent fuel rod simulator as a demonstration of analytical capabilities during a drying process. A mass spectrometer with specially designed inlets was used to monitor moisture and other gases at 150 kPa to 800 kPa for a test simulating a forced helium dehydration procedure and below 1 torr for tests mimicking a vacuum drying process. The dew point data from the mass spectrometer was found to be in good agreement with a solid-state moisture probe. A distinct advantage of the mass spectrometer system was the capability to directly sample from the hightemperature (>200 °C) head space expected in a prototypic scale experiment where a solid-state moisture probe would suffer considerable loss of accuracy or fail altogether. The operational and analytical experiences gained from this test series are poised to support an expansion to assembly-scale tests at prototypic length. These assemblies are designed to feature prototypic assembly hardware, advanced diagnostics for in situ internal rod pressure monitoring, and failed fuel rod simulators with engineered cladding defects to challenge the drying system with waterlogged fuel.
Abstract not provided.
The purpose of this report is to review technical issues relevant to the performance evaluation of dry storage systems during vacuum drying and long-term storage operations. It also provides updates on experimental components under development that are vital for pursuing advanced studies. Validation of the extent of water removal in a multi-assembly dry storage system using an industrial vacuum drying procedure is needed, as operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. Water remaining in canisters/casks upon completion of vacuum drying can lead to cladding corrosion, embrittlement, and breaching, as well as fuel degradation. Therefore, additional information is needed to evaluate the potential impacts of water retention on extended long-term dry storage. A general lack of data and experience modeling the drying process necessitates the testing of advanced concepts focused on the simulation of industrial vacuum drying. Smaller-scale tests that incorporate relevant physics and well-controlled boundary conditions are necessary to provide insight and guidance to the modeling of prototypic systems undergoing drying processes. This report describes the development and testing of waterproof, electrically-heated spent fuel rod simulators as a proof of concept to enable experimental simulation of the entire dewatering and drying process. This report also describes the preliminary development of specially-designed, unheated mock fuel rods for monitoring internal rod pressures and studying water removal from simulated failed fuel rods. A variety of moisture monitoring instrumentation is also being considered and will be downselected for the tracking of dewpoints of gas samples. The effects of cladding oxidation and crud on water retention in dry storage systems can be explored via separate effects tests (SETs) that would measure chemisorbed and physisorbed water content on cladding samples. The concepts listed above will be incorporated into an advanced dry cask simulator with multiple fuel assemblies in order to account for important inter-assembly heat-transfer physics. Plans are described for harvesting up to five full-length 5x5 laterally truncated assemblies from commercial 17x17 PWR skeleton components with the goal of constructing this simulator.
Abstract not provided.