Investigation of Nanoparticle Degradation in Hydrogen Fuel Cell Systems through Automated Electron Microscopy

Proton exchange membrane fuel cells (PEMFC) are promising devices for the deployment of hydrogen-powered heavy-duty vehicles, providing a higher efficiency for similar driving range and fueling time than the existing ones. However, PEMFCs still encounter durability challenges mainly due to catalyst degradation in the cathode. Mitigating these performance losses requires a better understanding of the degradation mechanisms under heavy-duty accelerated stress tests (ASTs) [1]. Scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) are key tools for the analysis of Pt and PtCo nanoparticle size, spatial distribution and composition [2]. Electron tomography is also used to determine the rate and type of degradation of catalyst nanoparticles as a function of their position on the carbon support. In this work, automated data acquisition software, paired with a custom Python code, have been used to study the effect of different accelerated stress tests (ASTs) on nanoparticle coarsening [2]. Figure 1 shows high-angle annular dark-field (HAADF)-STEM images and EDS maps comparing the cathodes of membrane electrode assemblies (MEAs) following an electrocatalyst AST performed under H2/N2 with that of the heavy-duty AST performed under H2/air. We will discuss how AST conditions affect considerably the spatial distribution of the nanoparticles across the electrode between the membrane and microporous layer. Although the median particle size increased more in the MEA aged under the heavy-duty AST, as determined using a high-throughput image analysis, the quantitative EDS measurements demonstrate that the electrocatalyst AST resulted in more Pt and Co dissolution from the cathode, which is another important indicator of electrocatalyst degradation. We will further present the impact of the relative humidity (% RH) on the degradation mechanisms demonstrated using the same approach. Electron tomography has been used to distinguish the Pt nanoparticles residing on the carbon support surface (exterior) from those within the pore structure (interior) in order to determine the relative stability of interior and exterior nanoparticles. As shown in Figure 2, we will compare the Pt catalyst particle size at the beginning of test (BOT) and end of test (EOT), and discuss the importance of automating the electron tomography workflow, i.e. acquisition, reconstruction, and visualization, to increase sampling and determine the standard deviation of these measurement. The outlook for utilizing low-dose cryo-tomography for limiting damage to the catalyst, support, and especially proton-conducting ionomer will also be discussed [3].

Amichi, Lynda↗

Field Response of Magnetic Vortices in Dusty Olivine From the Semarkona Chondrite

Current paleomagnetic studies have constrained the strength and longevity of the magnetic field generated by the solar nebula, which has broad implications for the early evolution of the solar system. Paleomagnetic evidence was recorded by nanoscale iron inclusions in olivine crystals in the Semarkona LL 3.0 chondrite. These dusty olivines have been shown to be credible carriers of ancient magnetic remanence. The small scale of the iron inclusions presents several challenges for defining their fundamental magnetic properties. In this work, we introduce the first correlative study of the response of these magnetic structures under applied laboratory fields. Results show that the majority of particles are in a single-vortex state and exhibit stable magnetic behavior in applied fields up to 200 mT. Experimental observations using Lorentz microscopy and magnetic transmission X-ray microscopy are shown to compare well with the results of finite-element micromagnetic simulations derived from 3-D models of the particles obtained using electron tomography. This correlative approach may be used to characterize the fundamental magnetic behavior of many terrestrial and extraterrestrial paleomagnetic carriers in the single-vortex to multivortex size range, which represent the vast majority of stable magnetic carriers in rocks and meteorites.

58 GEOSCIENCES↗

Model based atomic resolution tomography

Electron tomography is a valuable three-dimensional characterization method, but the technique has so far been limited to a nanometer scale resolution, and therefore complementary two-dimensional structural analysis is generally performed using other techniques. In this paper, computer simulations of the latest transmission electron microscope technologies are performed on a CeO{sub 2} supercell to investigate the extension of electron tomography to the atomic scale resolution, from a tilt series of high resolution electron microscopy (HREM) images. We showed that high-voltage and aberration-corrected microscopes were both capable of retrieving adjacent oxygen and Ce atoms for a thickness up to 2.5 nm. In the case where only a few tilt angle projections are in zone-axis orientations, we introduced a hybrid tomography method, whereby a lattice-resolved tomogram obtained from a few zone-axis projections is combined with the external shape reconstruction of the crystal from binary projections. Finally, we discussed some experimental challenges related to the proposed HREM tomography technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗