Sadrozinski, H.

Publications and source records attributed to Sadrozinski, H..

A first look at AS-ROC: a Si-Ge integrated chip readout for fast timing

Abstract Advances in timing detector technology require new specialized readout electronics. Applications demand below 10 ps time of arrival resolution and low power for a low repetition rate. A possible path to achieve O(10 ps) time resolution is an integrated chip using Silicon Germanium (SiGe) technology. Using DoE SBIR funding, Anadyne, Inc., in collaboration with UC Santa Cruz, has developed a prototype SiGe front-end readout chip optimized for low power and timing resolution. Two versions of the chip were produced with performance in simulation: a more power version with 10 ps resolution at 5 fC with 1.1 mW/channel, and a less power version with 10 ps resolution at 8 fC with 0.6 mW/channel.The chip was produced at Tower Semiconductor with 350 nm technology. The ASIC from the prototype run shows good performance: a rise time of 0.7–1 ns and 25 mV per fC response with RMS noise <1 mV. Simulation and results from the prototype will be reported in this paper.

Instruments & Instrumentation↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Electronics for Fast Timing

Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of uniformity of 50 μ m low-gain avalanche detectors at the Fermilab test beam

In this study, we report measurements of the uniformity of time resolution, signal amplitude, and charged particle detection efficiency across the sensor surface of low-gain avalanche detectors (LGAD). Comparisons of the performance of sensors with different doping concentrations and different active thicknesses are presented, as well as their temperature dependence and radiation tolerance up to 6 x 10 14 n/cm 2 . Results were obtained at the Fermilab test beam facility using 120 GeV proton beams, and a high precision pixel tracking detector. LGAD sensors manufactured by the Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) were studied. The uniformity of the sensor response in pulse height before irradiation was found to have a 2% spread. The signal detection efficiency and timing resolution in the sensitive areas before irradiation were found to be 100% and 30–40 ps, respectively. A “no-response” area between pads was measured to be about 130 μm for CNM and 170μm for HPK sensors. After a neutron fluence of 6 x 10 14 n/cm 2 the CNM sensor exhibits a large gain variation of up to a factor of 2.5 when comparing metalized and non-metalized sensor areas. An irradiated CNM sensor achieved a time resolution of 30 ps for the metalized area and 40 ps for the non-metalized area, while a HPK sensor irradiated to the same fluence achieved a 30 ps time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal formation in irradiated silicon detectors

In this paper we present an initial study on the effects induced by radiation on the signal generated by a minimum ionising particle in silicon detector. The results are obtained by implementing in the simulation programme Weightfield2 (WF2) charge carrier trapping and non linear distribution of the electric field. Results of sample simulations are presented, along with a discussion of the limitations of the current approach and ideas for future improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and construction of the 1{sup st} proton CT scanner

This paper discusses the design and operation of the 1{sup st} proton CT scanner for 3D imaging. Reduction of proton range uncertainties and improved dose accuracy in the patient for treatment planning are central goals. A central CT slice acquired by reconstruction of 134 million proton tracks through a 14 cm spherical polystyrene phantom with high and low density inserts is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗