Engineering Papers⌕ Search

Engineering topics

Saab, T.

Publications and source records attributed to Saab, T..

At least 37 records · Page 2

Improved WIMP-search reach of the CDMS II germanium data

CDMS II data from the five-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector weakly interacting massive particle (WIMP)-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to ~5 keV, to increase sensitivity near a WIMP mass of 8 GeV/c 2 . After unblinding, there were zero candidate events above a deposited energy of 10 keV and six events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of 1.8×10 –44 and 1.18×10 –41 at 90% confidence for 60 and 8.6 GeV/c 2 WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6) GeV/c 2 WIMPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter effective field theory scattering in direct detection experiments

We examine the consequences of the effective field theory (EFT) of dark matter–nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scalability study of solid xenon

We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employed a cryostat cooled by liquid nitrogen combined with a xenon purification and chiller system. A modified {\it Bridgeman's technique} reproduces a large scale optically transparent solid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data

We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from Pb210decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we also perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. Finally, we confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Direct Limits on Lightly Ionizing Particles with Electric Charge Less than e / 6

While the standard model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically produced relativistic particles with electric charge lower than e / 6 . A search for tracks in the six stacked detectors of each of two of the CDMS II towers finds no candidates, thereby excluding new parameter space for particles with electric charges between e / 6 and e / 200 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scalability, Scintillation Readout and Charge Drift in a Kilogram Scale Solid Xenon Particle Detector

We report a demonstration of the scalability of optically transparent xenon in the solid phase for use as a particle detector above a kilogram scale. We employ a liquid nitrogen cooled cryostat combined with a xenon purification and chiller system to measure the scintillation light output and electron drift speed from both the solid and liquid phases of xenon. Scintillation light output from sealed radioactive sources is measured by a set of high quantum efficiency photomultiplier tubes suitable for cryogenic applications. We observed a reduced amount of photons in solid phase compared to that in liquid phase. We used a conventional time projection chamber system to measure the electron drift time in a kilogram of solid xenon and observed faster electron drift speed in the solid phase xenon compared to that in the liquid phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter searches with the CDMS II experiment

The CDMS II experiment ran between 2003 and 2009. A total of 30 germanium and silicon ZIP detectors were operated, producing a high quality set of data that has been analyzed for evidence of and placed leading constraints on standard, low-mass, electron-recoil, and annually modulating WIMP interactions. This article will describe the general operation principles behind the CDMS detectors, report on the results of major Ge and Si detector analyses, and describe the current and future activities of the SuperCDMS program.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for Low-Mass Weakly Interacting Massive Particles with SuperCDMS

We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1:2 10-42cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.

Search for Low-Mass WIMPs with SuperCDMS↗

Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches

The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Furthermore, surface event rejection capabilities were tested with two 210 Pb sources producing ~130 beta decays/hr. We found that in ~800 live hours, no events leaked into the 8–115 keV signal region, giving upper limit leakage fraction 1.7 x 10 -5 at 90% C.L., corresponding to<0.6 surface event background in the future 200-kg SuperCDMS SNOLAB experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SuperCDMS status from Soudan and plans for SNOLab

Matter, as we know it, makes up less than 5% of the Universe. Various astrophysical observations have confirmed that one quarter of the Universe and most of the matter content in the Universe is made up of Dark Matter. The nature of Dark Matter is yet to be discovered and is one of the biggest questions in Physics. Particle Physics combined with astrophysical measurements of the abundance gives rise to a Dark Matter candidate called Weakly Interacting Massive Particle (WIMP). The low density of WIMPs in the galaxies and the extremely weak nature of the interaction with ordinary matter make detection of the WIMP an extraordinarily challenging task, with abundant fakes from various radioactive and cosmogenic backgrounds with much stronger electromagnetic interaction. The extremely weak nature of the WIMP interaction dictates detectors that have extremely low naturally occurring radioactive background, a large active volume (mass) of sensitive detector material to maximize statistics, a highly efficient detector based rejection mechanism for the dominant electromagnetic background and sophisticated analysis techniques to reject any residual background. This paper describes the status of the SuperCDMS experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for inelastic dark matter with the CDMS II experiment

Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events, the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from a Low-Energy Analysis of the CDMS II Germanium Data

We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from weakly interacting massive particles (WIMPs) with masses below {approx}10 GeV/c{sup 2}. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c{sup 2} and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Materials Development for Auxiliary Components for Large Compact Mo/Au TES Arrays

We describe our current fabrication process for arrays of superconducting transition edge sensor microcalorimeters, which incorporates superconducting Mo/Au bilayers and micromachined silicon structures. We focus on materials and integration methods for array heatsinking with our bilayer and micromachining processes. The thin superconducting molybdenum bottom layer strongly influences the superconducting behavior and overall film characteristics of our molybdenum/gold transition-edge sensors (TES). Concurrent with our successful TES microcalorimeter array development, we have started to investigate the thin film properties of molybdenum monolayers within a given phase space of several important process parameters. The monolayers are sputtered or electron-beam deposited exclusively on LPCVD silicon nitride coated silicon wafers. In our current bilayer process, molybdenum is electron-beam deposited at high wafer temperatures in excess of 500 degrees C. Identifying process parameters that yield high quality bilayers at a significantly lower temperature will increase options for incorporating process-sensitive auxiliary array components (AAC) such as array heat sinking and electrical interconnects into our overall device process. We are currently developing two competing technical approaches for heat sinking large compact TES microcalorimeter arrays. Our efforts to improve array heat sinking and mitigate thermal cross-talk between pixels include copper backside deposition on completed device chips and copper-filled micro-trenches surface-machined into wafers. In addition, we fabricated prototypes of copper through-wafer microvias as a potential way to read out the arrays. We present an overview on the results of our molybdenum monolayer study and its implications concerning our device fabrication. We discuss the design, fabrication process, and recent test results of our AAC development.

Finkbeiner, F. m.↗

Determination of Lateral Diffusivity in Single Pixel X-ray Absorbers with Implications for Position Dependent Excess Broadening

An ideal microcalorimeter is characterized by a constant energy resolution across the sensor's dynamic range. Any dependence of pulse shape on the position within the absorber where an event occurs leads to a degradation in resolution that is linear with event s energy (excess broadening). In this paper we present a numerical simulation that was developed to model the variation in pulse shape with position based on the thermal conductivity within the absorber and between the absorber, sensor, and heat bath, for arbitrarily shaped absorbers and sensors. All the parameters required for the simulation can be measured from actual devices. We describe how the thermal conductivity of the absorber material is determined by comparing the results of this model with data taken from a position sensitive detector in which any position dependent effect is purposely emphasized by making a long, narrow absorber that is read out by sensors on both end. Finally, we present the implications for excess broadening given the measured parameters of our X-ray microcalorimeters.

Saab, T.↗