Interfacial Electronic Structure of C60/ClAlPc on a MoO3 Layer After Thermal Treatment
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Ryu, S.
Explore the source record for details and available documents.
Purpose: Normal organ segmentation is one time-consuming and labor-intensive step for lung radiotherapy treatment planning. The aim of this study is to evaluate the performance of a multi-atlas based segmentation approach for automatic organs at risk (OAR) delineation. Methods: Fifteen Lung stereotactic body radiation therapy patients were randomly selected. Planning CT images and OAR contours of the heart - HT, aorta - AO, vena cava - VC, pulmonary trunk - PT, and esophagus – ES were exported and used as reference and atlas sets. For automatic organ delineation for a given target CT, 1) all atlas sets were deformably warped to the target CT, 2) the deformed sets were accumulated and normalized to produce organ probability density (OPD) maps, and 3) the OPD maps were converted to contours via image thresholding. Optimal threshold for each organ was empirically determined by comparing the auto-segmented contours against their respective reference contours. The delineated results were evaluated by measuring contour similarity metrics: DICE, mean distance (MD), and true detection rate (TD), where DICE=(intersection volume/sum of two volumes) and TD = {1.0 - (false positive + false negative)/2.0}. Diffeomorphic Demons algorithm was employed for CT-CT deformable image registrations. Results: Optimal thresholds were determined to be 0.53 for HT, 0.38 for AO, 0.28 for PT, 0.43 for VC, and 0.31 for ES. The mean similarity metrics (DICE[%], MD[mm], TD[%]) were (88, 3.2, 89) for HT, (79, 3.2, 82) for AO, (75, 2.7, 77) for PT, (68, 3.4, 73) for VC, and (51,2.7, 60) for ES. Conclusion: The investigated multi-atlas based approach produced reliable segmentations for the organs with large and relatively clear boundaries (HT and AO). However, the detection of small and narrow organs with diffused boundaries (ES) were challenging. Sophisticated atlas selection and multi-atlas fusion algorithms may further improve the quality of segmentations.
Purpose: To compare three-dimensional conformal radiotherapy (3D CRT) and volumetric-modulated arc therapy (VMAT) in lung stereotactic body radiation therapy (SBRT) Methods: A retrospective study of clinically treated lung SBRT cases treated between 2010 and 2015 at our hospital was performed. All treatment modalities were included in this evaluation (VMAT, 3D CRT, static IMRT, and dynamic conformal arc therapy). However, the majority of treatment modalities were either VMAT or 3D CRT. Treatment times of patients and dosimetric plan quality metrics were compared. Treatment times were calculated based on the time the therapist opened and closed the patient’s treatment plan. This treatment time closely approximates the utilization time of the treatment room. The dosimetric plan quality metrics evaluated include ICRU conformity index, the volume of 105% prescribed dose outside PTV, the ratio of volume of 50% prescribed dose to the volume of PTV, the percentage of maximum dose at 2 cm away from PTV to the prescribed dose, and the V20 (percentage of lung volume receiving 20 Gy or more). Results: Treatment time comparisons show that on average VMAT has shorter treatment times than 3D CRT. Dose conformity, defined by the ICRU conformity index, and high dose spillage, defined by the volume of 105% dose outside the PTV, is reduced when using VMAT compared to 3D CRT. V20 and intermediate dose spillage/fall-off metrics of VMAT and 3D are not significantly different. Conclusion: Clinically treated lung SBRT cases indicate VMAT is superior to 3D with regard to shorter treatment times, plan dose conformity, and plan high dose spillage.
Purpose: The commercially available Leipzig-style Cone for High Dose Rate (HDR) Brachytherapy has a steep depth dose curve and a non-uniform dose distribution. This work shows the performance of a Ring Surface Applicator created using a 3D printer that can generate a better dose distribution. Calculated doses were verified with film measurement. Methods: The water equivalent red-ABS plastic was used to print the Ring Surface Applicator which hosts three catheters: a center piece with a straight catheter and two concentric rings with diameters of 3.5 and 5.5 cm. Gafchromic EBT2 film, Epson Expression 10000 flatbed scanner, and the online software at radiochromic.com were used to analyze the measured data. 10cm×10cm piece of film was sandwiched between two 15×10×5cm3 polystyrene phantoms. The applicator was positioned directly on top of the phantom. Measurement was done using dwell time and positions calculated by Eclipse BrachyVision treatment planning system (RTP). Results: Depth dose curve was generated from the plan and measurement. The results show that the measured and calculated depth dose were in agreement (<3%) from surface to 4mm depth. A discrepancy of 6% was observed at 5 mm depth, where the dose is typically prescribed to. For depths deeper than 5 mm, the measured doses were lower than those calculated by Eclipse BrachyVision. This can be attributed to a combination of simple calculation algorithm using TG-43 and the lack of inhomogeneity correction. Dose profiles at 5 mm depth were also generated from TPS calculation and measured with film. The measured and calculated profiles are similar. Consistent with the depth dose curve, the measured dose is lower than the calculated. Conclusion: Our results showed that the Ring Surface Applicator, printed using 3D printer, can generate more uniform dose distribution within the target volume and can be safely used in the clinic.
Purpose: Grid therapy (GT), which generates highly spatially modulated dose distributions, can deliver single- or hypo-fractionated radiotherapy for large tumors without causing significant toxicities. GT may be applied in combination with immunotherapy, in light of recent preclinical data of synergetic interaction between radiotherapy and immunotherapy. However, conventional GT uses only one field, which does not have the advantage of multi-fields in 3D conformal-RT or IMRT. We have proposed a novel MLC-based, inverse-planned multi-field 3D GT technique. This study aims to test its deliverability and dosimetric accuracy. Methods: A lattice of small spheres was created as the boost volume within a large target. A simultaneous boost IMRT plan with 8-Gy to the target and 20-Gy to the boost volume was generated in the Eclipse treatment planning system (AAA v10) with a HD120 MLC. Nine beams were used, and the gantry and couch angles were selected so that the spheres were perfectly aligned in every beams eye view. The plan was mapped to a phantom with dose scaled. EBT3 films were calibrated and used to measure the delivered dose. Results: The IMRT plan generated a highly spatially modulated dose distribution in the target. D95%, D50%, D5% for the spheres and the targets in Gy were 18.5, 20.0, 21.4 and 7.9, 9.8, 16.1, respectively. D50% for a 1cm ring 1cm outside the target was 2.9-Gy. Film dosimetry showed good agreement between calculated and delivered dose, with an overall gamma passing rate of 99.6% (3%/1mm). The point dose differences for different spheres varied from 1–6%. Conclusion: We have demonstrated the deliverability and dose calculation accuracy of the MLC-based inversely optimized multi-field GT technique, which achieved a brachytherapy-like dose distribution. Single-fraction high dose can be delivered to the spheres in a large target with minimal dose to the surrounding normal tissue.
Purpose: To evaluate the potential advantages of jaw tracking for intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in spine radiosurgery. Methods: VMAT and IMRT plans were retrospectively generated for ten patients. Six plans for each patient were created in the Eclipse treatment planning system for a Varian Truebeam equipped with a Millennium 120 MLC. Plans were created to study IMRT and VMAT plans with and without jaw tracking, as well as IMRT plans of different flattening filter free (FFF) energies. Plans were prescribed to the 90% isodose line to 16 or 18 Gy in one fraction to cover 95% of the target. Planning target volume (PTV) coverage, conformity index (CI), dose to spinal cord, distance to fall off from the 90% to 50% isodose line (DTF), as well as delivery time were evaluated. Ion chamber and film measurements were performed to verify calculated and measured dose distributions. Results: Jaw tracking decreased the spinal cord dose for both IMRT and VMAT plans, but a larger decrease was seen with the IMRT plans (p=0.004 vs p=0.04). The average D10% for the spinal cord was least for the 6MV FFF IMRT plan with jaw tracking and was greatest for the 10MV FFF plan without jaw tracking. Treatment times between IMRT and VMAT plans with or without jaw tracking were not significantly different. Measured plans showed greater than 98.5% agreement for planar dose gamma analysis (3%/2 mm) and less than 2.5% for point dose analysis compared to calculated plans. Conclusion: Jaw tracking can be used to help decrease spinal cord dose without any change in treatment delivery or calculation accuracy. Lower dose to the spinal cord was achieved using 6 MV beams compared to 10 MV beams, though 10 MV may be justified in some cases to decrease skin dose.
We report the observation of B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(980) and evidence for B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(1370), which are CP eigenstate decay modes. These results are obtained from 121.4 fb{sup -1} of data collected at the {Upsilon}(5S) resonance with the Belle detector at the KEKB e{sup +}e{sup -} collider. We measure the branching fractions B(B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(980);f{sub 0}(980){yields}{pi}{sup +}{pi}{sup -})=(1.16{sub -0.19}{sup +0.31}(stat){sub -0.17}{sup +0.15} (syst){sub -0.18}{sup +0.26}(N{sub B{sub s}{sup (*)}}{sub B{sub s}{sup (*)}}))x10{sup -4} with a significance of 8.4{sigma}, and B(B{sub s}{sup 0}{yields}J/{psi}f{sub 0}(1370);f{sub 0}(1370){yields}{pi}{sup +}{pi}{sup -})=(0.34{sub -0.14}{sup +0.11}(stat){sub -0.02}{sup +0.03} (syst){sub -0.05}{sup +0.08} (N{sub B{sub s}{sup (*)}}{sub B{sub s}{sup (*)}}))x10{sup -4} with a significance of 4.2{sigma}. The last error listed is due to uncertainty in the number of produced B{sub s}{sup (*)}B{sub s}{sup (*)} pairs.
We present a study of {tau}{sup -{yields}{pi}-{pi}+{pi}-{nu}}{sub {tau}}, {tau}{sup -{yields}}K{sup -{pi}+{pi}-{nu}}{sub {tau}}, {tau}{sup -{yields}}K{sup -}K{sup +{pi}-{nu}}{sub {tau}}, and {tau}{sup -{yields}}K{sup -}K{sup +}K{sup -{nu}}{sub {tau}} decays using a 666 fb{sup -1} data sample collected with the Belle detector at the KEKB asymmetric-energy e{sup +}e{sup -} collider at and near a center-of-mass energy of 10.58 GeV. The branching fractions are measured to be B({tau}{sup -{yields}{pi}-{pi}+{pi}-{nu}}{sub {tau}})=(8.42{+-}0.00{sub -0.25}{sup +0.26})x10{sup -2}, B({tau}{sup -{yields}}K{sup -{pi}+{pi}-{nu}}{sub {tau}})=(3.30{+-}0.01{sub -0.17}{sup +0.16})x10{sup -3}, B({tau}{sup -{yields}}K{sup -}K{sup +{pi}-{nu}}{sub {tau}})=(1.55{+-}0.01{sub -0.05}{sup +0.06})x10{sup -3}, and B({tau}{sup -{yields}}K{sup -}K{sup +}K{sup -{nu}}{sub {tau}})=(3.29{+-}0.17{sub -0.20}{sup +0.19})x10{sup -5}, where the first uncertainty is statistical and the second is systematic. These branching fractions do not include contributions from modes in which a {pi}{sup +{pi}-} pair originates from a K{sub S}{sup 0} decay. We also present the unfolded invariant mass distributions for these decays.
KIMS is a dark matter search experiment using low background CsI(TB) crystals at Yangyang Underground Laboratory in Korea. With a total exposure of 3409 kg{center_dot}d data, we set a new limit on WIMP-nucleon cross section. We achieved the most stringent limit on the spin-dependent interaction for a pure proton case. We were able to exclude the DAMA signal region for both spin-dependent and spin-independent interaction for the WIMP mass greater than 20 GeV/c{sup 2}. KIMS experiment is upgraded with 12 CsI(TB) crystals corresponding to a total mass of 104 kg and accumulating data since Jan. 2008.