Engineering Papers⌕ Search

Engineering topics

Rusby, D.

Publications and source records attributed to Rusby, D..

Ultrabroad-band x-ray source using a picosecond, laser-driven plasma accelerator

An ultrabroad-band x-ray source, with photon energies from 10 keV to >1 MeV, based on a picosecond laser-driven plasma accelerator, is characterized and used to radiograph high-energy-density-science relevant targets. The measured yield of 10 12 photons/shot is reaching the necessary photon yields to radiograph, in a single shot, high areal density objects and matter under extreme conditions. By focusing a short laser pulse (120 J, 1 ps) into a gas jet, a < 100 mrad electron beam with energies up to 350 MeV and up to 70 nC of charge was produced by a combination of laser self-modulation instability and direct laser acceleration. A foil placed at the exit of the gas jet is used to convert part of the electron beam energy into x rays through inverse bremsstrahlung and/or inverse Compton scattering, generating a bright, broad-band, high-photon-energy beam. This beam is used to radiograph a gold half hohlraum with a high-density sphere inside with relevant characteristics for high-energy-density science and inertial confinement fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray continuum spectroscopy of inertial confinement fusion implosions at the National Ignition Facility

A methodology for measuring x-ray continuum spectra of inertial confinement fusion (ICF) implosions is described. The method relies on the use of ConSpec, a high-throughput spectrometer using a highly annealed pyrolytic graphite crystal , which measures the spectra in the ≃20–30 keV range. Due to its conical shape, the crystal is sagittally focusing a Bragg-reflected x-ray spectrum into a line, which enhances the recorded x-ray emission signal above the high neutron-induced background accompanying ICF implosions at the National Ignition Facility. To improve the overall measurement accuracy, the sensitivity of the spectrometer measured in an off-line x-ray laboratory setting was revised. The error analysis was expanded to include the accuracy of the off-line measurements, the effect of the neutron-induced background, as well as the influence of possible errors in alignment of the instrument to the ICF target. Here we demonstrate how the improved methodology is applied in the analysis of ConSpec data with examples of a relatively low-neutron-yield implosion using a tritium–hydrogen–deuterium mix as a fuel and a high-yield deuterium–tritium (DT) implosion producing high level of the background. In both cases, the shape of the measured spectrum agrees with the exponentially decaying spectral shape of bremsstrahlung emission to within ±10%. In the case of the high-yield DT experiment, non-monotonic deviations slightly exceeding the measurement uncertainties are observed and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser

Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for E photon = 0.5-30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at I laser ≈ 2 x 10 18 W/cm 2 with CPCs is observed, with doses of >10 rad in air at 1 m for E photon > 0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. Hence these results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A combined MeV-neutron and x-ray source for the National Ignition Facility

We report that in support of future radiation-effects testing, a combined environment source has been developed for the National Ignition Facility (NIF), utilizing both NIF’s long-pulse beams, and the Advanced Radiographic Capability (ARC) short pulse lasers. First, ARC was used to illuminate a gold foil at high-intensity, generating a significant x-ray signal > 1 MeV. This was followed by NIF 10 ns later to implode an exploding pusher target filled with fusionable gas for neutron generation. The neutron and x-ray bursts were incident onto a retrievable, close-standoff diagnostic snout. With separate control over both neutron and x-ray emission, the platform allows for tailored photon and neutron fluences and timing on a recoverable test sample. The platform exceeded its initial fluence goals, demonstrating a neutron fluence of 2.3 ×10 13 n/cm 2 and an x-ray dose of 7 krad.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Monte Carlo technique to model performance of streak camera-based time-resolving x-ray spectrometers

A Monte Carlo technique has been developed to simulate the expected signal and the statistical noise of x-ray spectrometers that use streak cameras to achieve the time resolution required for ultrafast diagnostics of laser-generated plasmas. The technique accounts for statistics from both the photons incident on the streak camera’s photocathode and the electrons emitted by the photocathode travelling through the camera’s electron optics to the sensor. We use the technique to optimize the design of a spectrometer, which deduces the temporal history of electron temperature of the hotspot in an inertial confinement fusion implosion from its hard x-ray continuum emission spectra. The technique is general enough to be applied to any instrument using an x-ray streak camera.

Stoupin, S. (ORCID:0000000226225270)↗

Enhancement of high energy X-ray radiography using compound parabolic concentrator targets

We report an increase in MeV energy bremsstrahlung x-ray production using compound parabolic concentrators (CPC) compared to flat solid targets during relativistic laser-plasma experiments on a 140 J, 150 fs laser system using an f/40 focusing optic. CPC enhanced targets show a > 3x increase in high energy x-ray production over planar foil targets. Furthermore, this enhancement in x-ray energy spectra shows a direct improvement in the radiography of an image quality indicator (IQI) object with a 20 g/cm 2 areal density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scaling of laser-driven electron and proton acceleration as a function of laser pulse duration, energy, and intensity in the multi-picosecond regime

A scaling study of short-pulse laser-driven proton and electron acceleration was conducted as a function of pulse duration, laser energy, and laser intensity in the multi-picosecond (ps) regime (∼0.8 ps–20 ps). Maximum proton energies significantly greater than established scaling laws were observed, consistent with observations at other multi-ps laser facilities. In addition, maximum proton energies and electron temperatures in this regime were found to be strongly dependent on the laser pulse duration and preplasma conditions. A modified proton scaling model is presented that is able to better represent the accelerated proton characteristics in this multi-ps regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterisation of a laser plasma betatron source for high resolution x-ray imaging

Abstract We report on the characterisation of an x-ray source, generated by a laser-driven plasma wakefield accelerator. The spectrum of the optimised source was consistent with an on-axis synchrotron spectrum with a critical energy of 13.8 − 1.9 + 2.2 keV and the number of photons per pulse generated above 1 keV was calculated to be 6 − 0.9 + 1.2 × 10 9 . The x-ray beam was used to image a resolution grid placed 37 cm from the source, which gave a measured spatial resolution of 4 µ m × 5 µ m. The inferred emission region had a radius and length of 0.5 ± 0.2 µ m and 3.2 ± 0.9 mm respectively. It was also observed that laser damage to the exit aperture of the gas cell led to a reduction in the accelerated electron beam charge and a corresponding reduction in x-ray flux due to the change in the plasma density profile.

plasma acceleration↗

Scaling of laser-driven electron and proton acceleration as a function of laser pulse duration, energy, and intensity in the multi-picosecond regime

A scaling study of short-pulse laser-driven proton and electron acceleration was conducted as a function of pulse duration, laser energy, and laser intensity in the multi-picosecond (ps) regime (~0.8 ps–20 ps). Furthermore, maximum proton energies significantly greater than established scaling laws were observed, consistent with observations at other multi-ps laser facilities. In addition, maximum proton energies and electron temperatures in this regime were found to be strongly dependent on the laser pulse duration and preplasma conditions. A modified proton scaling model is presented that is able to better represent the accelerated proton characteristics in this multi-ps regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FY20 LLNL Experimental Programs at Omega

In Fiscal Year 2020 (FY20), Lawrence Livermore National Laboratory’s (LLNL’s) High-Energy-Density Physics (HED) and Indirect Drive Inertial Confinement Fusion (ICF-ID) programs conducted numerous campaigns on the OMEGA and OMEGA-EP (EP) laser systems. This was the 22ndyear of National Lab collaborative experiments at OMEGA since the Nova Laser at LLNL shut down in 1999, building upon prior collaborations. In FY20overall,these LLNL programs led 375target shots, with 166shots using just the OMEGA laser system and209 shots using just the EP laser system. Approximately 34% of the total number of shots (35OMEGA shots and 93EP shots) supported the Indirect Drive Inertial Confinement Fusion Campaign. The remaining 66% (131OMEGA-only shots and 116EP-only shots) were dedicated to experiments for High-Energy-Density Physics.Highlights of the various HED and ICF-ID campaigns are summarized in the following reports.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗