Engineering Papers⌕ Search

Engineering topics

Rumyantseva, N.

Publications and source records attributed to Rumyantseva, N..

Erratum: Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Regretfully, the author list of the original paper did not contain the members of the groups being responsible for the HPGe screening, Radon emanation measurement and ICPMS surface characterization works. As the work performed is to be considered more than “just service work”, the authors together with the members of these groups have decided to amend the authors list. At publication the following authors were not included in the author list: • From Pacific Northwest National Laboratory, Richland, WA, U.S.A.: E.W. Hoppe, I.J. Arnquist, K.P. Hobbs, A.D. French, M.L. diVacri • From INFN, Laboratori Nazionali del Gran Sasso, 67100 Assergi, Italy: M. Laubenstein • From M. Smoluchowski Institute of Physics, Jagiellonian University, 30-348 Krakow, Poland: G. Zuzel The metadata of the present erratum are already correct.

99 GENERAL AND MISCELLANEOUS↗

Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare events like neutrinoless double-beta decay or dark matter recoils. Such optically active structures improve the identification and rejection efficiency of backgrounds events, like this improving the sensitivity of experiments. This paper reports on the production of radiopure and transparent PEN plates These structures can be used to mount germanium detectors operating in cryogenic liquids (LAr, LN). Thus, as first application PEN holders will be used to mount the Ge detectors in the LEGEND-200 experiment. The whole process from cleaning the raw material to testing the PEN active components under final operational conditions is reported.

47 OTHER INSTRUMENTATION↗

Limit on the radiative neutrinoless double electron capture of 36 Ar from GERDA Phase I

Neutrinoless double electron capture is a process that, if detected, would give evidence of lepton number violation and the Majorana nature of neutrinos. Here, a search for neutrinoless double electron capture of 36 Ar has been performed with germanium detectors installed in liquid argon using data from Phase I of the GERmanium Detector Array (Gerda) experiment at the Gran Sasso Laboratory of INFN, Italy. No signal was observed and an experimental lower limit on the half-life of the radiative neutrinoless double electron capture of 36 Ar was established: T 1/2 > 3.6 × 10 21 years at 90% CI.

74 ATOMIC AND MOLECULAR PHYSICS↗

Results on $\beta \beta $ decay with emission of two neutrinos or Majorons in $^{76}$ Ge from GERDA Phase I: GERDA Collaboration

A search for neutrinoless ββ decay processes accompanied with Majoron emission has been performed using data collected during Phase I of the GERmanium Detector Array (GERDA) experiment at the Laboratori Nazionali del Gran Sasso of INFN (Italy). Processes with spectral indices n = 1,2,3,7 were searched for. No signals were found and lower limits of the order of 10 23 yr on their half-lives were derived, yielding substantially improved results compared to previous experiments with 76 Ge. A new result for the half-life of the neutrino-accompanied ββ decay of 76Ge with significantly reduced uncertainties is also given, resulting in T 2ν 1/2 = (1.926 ± 0.094) × 10 21 yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvement of the energy resolution via an optimized digital signal processing in GERDA Phase I

An optimized digital shaping filter has been developed for the Gerda experiment which searches for neutrinoless double beta decay in $^{76}$Ge. The Gerda Phase I energy calibration data have been reprocessed and an average improvement of 0.3 keV in energy resolution (FWHM) corresponding to 10% at the $Q$ value for $0\nu \beta \beta $0νββ decay in $^{76}$Ge is obtained. This is possible thanks to the enhanced low-frequency noise rejection of this Zero Area Cusp (ZAC) signal shaping filter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production, characterization and operation of $^{76}$Ge enriched BEGe detectors in GERDA

The GERmanium Detector Array (Gerda) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of 76 Ge. Germanium detectors made of material with an enriched 76 Ge fraction act simultaneously as sources and detectors for this decay. During Phase I of theexperiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new 76 Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in Gerda during Phase I. The present article reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the 76 Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. Lastly, the detector performance fulfills the requirements needed for the physics goals of Gerda Phase II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse shape discrimination for Gerda Phase I data

The GERDA experiment located at the Laboratori Nazionali del Gran Sasso of INFN searches for neutrinoless double beta (0νββ) decay of 76 Ge using germanium diodes as source and detector. In Phase I of the experiment eight semi-coaxial and five BEGe type detectors have been deployed. The latter type is used in this field of research for the first time. All detectors are made from material with enriched 76 Ge fraction. The experimental sensitivity can be improved by analyzing the pulse shape of the detector signals with the aim to reject background events. This paper documents the algorithms developed before the data of Phase I were unblinded. The double escape peak (DEP) and Compton edge events of 2.615 MeV γ rays from 208Tl decays as well as two-neutrino double beta (2νββ) decays of 76 Ge are used as proxies for 0νββ decay. For BEGe detectors the chosen selection is based on a single pulse shape parameter. It accepts 0.92 ± 0.02 of signal-like events while about 80 % of the background events at Qββ = 2039 keV are rejected. For semi-coaxial detectors three analyses are developed. The one based on an artificial neural network is used for the search of 0νββ decay. It retains 90 % of DEP events and rejects about half of the events around Qββ . The 2νββ events have an efficiency of 0.85±0.02 and the one for 0νββ decays is estimated to be 0.90 +0.05 -0.09 . A second analysis uses a likelihood approach trained on Compton edge events. The third approach uses two pulse shape parameters. The latter two methods confirm the classification of the neural network since about 90 % of the data events rejected by the neural network are also removed by both of them. In general, the selection efficiency extracted from DEP events agrees well with those determined from Compton edge events or from 2νββ decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗