Use of Traveling Wave Signatures in Medium-Voltage Distribution Systems for Fault Detection and Location

Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

14 SOLAR ENERGY↗

Power converter circuitry for photovoltaic devices

Power converter circuitry includes a direct current (DC) input comprising a first DC input node and a second DC input node, an alternating current (AC) output comprising a first AC output node coupled to the first DC input node and a second AC output node, a first boost switch coupled between the second DC input node and a boost intermediate node, a second boost switch coupled between the boost intermediate node and a common node, a boost inductor coupled between the boost intermediate node and the first DC input node, a link capacitor coupled between the second DC input node and the common node, a first half-bridge switch coupled between the second DC input node and a half-bridge intermediate node, a second half-bridge switch coupled between the half-bridge intermediate node and the common node, and a half-bridge inductor coupled between the half-bridge intermediate node and the second AC output node.

Ayyanar, Rajapandian↗

LCOE Design Optimization Using Genetic Algorithm with Improved Component Models for Medium-Voltage Transformerless PV Inverters

For real-world installations of photovoltaic and other renewable energy resources, the critical design metric is the levelized cost of energy (LCOE); however, many power electronics design optimizations are performed with efficiency and power density as the primary design goals. Recent work has shown that a new LCOE-focused optimization approach can yield improved system designs balancing cost and energy generation. This paper expands the LCOE optimization approach by considering comprehensive optimization parameters, adding new modeling of inductor cost, extending the semiconductor model to include effects of losses on housing cost, and implementing a genetic algorithm to improve computation efficiency.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Highly Reliable Multi-Port Smart Inverter Modules for PV-Based Energy Systems

Generally, large electrolytic capacitors (E-caps) are required to decouple the double-line frequency power fluctuation inherent in all single-phase dc-ac or ac-dc converters. These E-caps pose the weak link in the photovoltaic (PV) inverter because they have poor reliability as a result of short life expectancy and higher equivalent series resistance (ESR) which leads to lower system efficiency. In this paper, multiport smart dual-inverter modules are proposed for residential PV inverter systems with balanced outputs to eliminate the requirement of large decoupling capacitors, thus leading to more reliable and highly efficient inverter modules. The balanced dual outputs are controlled in phase quadrature such that the double frequency current is completely eliminated. One phase supports the standalone residential loads, and the other phase interfaces with the grid, which is synchronized to the utility grid. Also, the proposed modular configuration is scalable to accommodate higher power rating by stacking and paralleling multiple modules. Simulation results for the dual-inverter modules rated for 1 kW each are presented to validate the proposed concept. Experimental results from a controller hardware-in-the-loop (CHIL) platform also verify its feasibility.

14 SOLAR ENERGY↗

GaN‐based split phase transformer‐less PV inverter with auxiliary ZVT circuit

This paper explores performance enhancement of the common ground dynamic dc‐link (CGDL) inverter for single phase photovoltaic (PV) applications by a combination of gallium nitride (GaN) devices, split phase topology, coupled inductors, and zero voltage transition (ZVT) scheme. The CGDL inverter has the inherent advantage of minimised dc‐link capacitance and negligible leakage current due to the common ground configuration, but its reported efficiency was usually lower because of the higher dc‐link voltage used for the reduction of decoupling capacitance to a great extent. To solve the efficiency problem, in this study, a soft switching circuit is proposed for the first stage, while a coupled inductor integrated magnetics is incorporated in the second stage to reduce inductor loss, volume, and cost. Both of these topological improvements combined with the use of GaN devices facilitate in achieving high efficiency without compromising converter power density. Extensive experimental results are provided from a GaN based 1 kVA hardware prototype to demonstrate the superior performance of the CGDL inverter attaining a peak efficiency of 98.7% and a California Energy Commission efficiency of 98.5% at 75/50 kHz switching frequency.

Xia, Yinglai↗

Levelized-Cost-of-Electricity-Driven Design Optimization for Medium-Voltage Transformerless Photovoltaic Converters

Design approaches for power electronics are typically focused on efficiency and power density; however, these strategies do not guarantee cost optimality in any well-defined sense. To overcome this shortcoming, we propose a design framework that yields circuit parameters that minimize the levelized cost of electricity (LCOE) of a generation system. LCOE serves as a meaningful metric since it captures total lifetime costs - including hardware, balance of system, and maintenance costs - and includes the impacts of power conversion efficiency and revenue from harvested energy. To obtain a tractable design problem, we formulate an approximate LCOE improvement model that quantifies the changes in LCOE resulting from a candidate converter design. We apply this framework to a multilevel cascaded topology for low-voltage dc to medium-voltage ac conversion without line-frequency transformers. An example 200 kW commercial-scale system is studied and the solution yields a design with 15 cascaded stages, 98.01% efficiency, and an LCOE reduction of 2.0%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Variable Switching Frequency Scheme to Reduce Loss of Single-Phase Grid-Connected Inverter With Unipolar and Bipolar PWM

Reducing the power loss of a converter without increasing its volume or cost in hardware has always been a much sought-after but challenging goal. This article proposes a comprehensive variable switching frequency (VSF) scheme to improve the overall system efficiency while still meeting a given total harmonic distortion (THD) requirement without any hardware changes, achieved only by changes to the controller. In this article, it is analyzed that for the H-bridge inverter, the inductor copper loss and the switch conduction loss are independent of the switching frequency (SF), while the device switching loss and the inductor core loss are functions of the SF. This article aims at weighting the combined switching loss and inductor core loss for both the unipolar and bipolar modulation techniques, with the constraint on the output THD, which, for fixed passive components, is a function of inductor ripple current that in turn depends on the SF. An optimal VSF scheme is devised through rigorous mathematical analysis of the output ripple component and the SF-dependent losses. In each switching cycle, the inductor ripple current is predicted with the circuit parameters, such as duty cycle, switching period, inductance, and dc voltage, and by implementing the VSF scheme, the current ripple is optimally varied such as to satisfy the THD requirement while reducing the SF-dependent losses. A generalized method to design VSF schemes for any topology and specifications is also presented, which would help future users in designing the VSF controller. A 1-kW H-bridge inverter using SiC MOSFETs and powdered iron/ferrite core has been built to validate the theoretical analysis. Both constant SF (CSF) scheme (200 kHz) and optimal VSF scheme with simple controller modification have been implemented in the experimental prototype using DSP TMS320f28335. Compared with the CSF scheme, the optimal VSF scheme shows a significant improvement in the system efficiency at rated power from 94.7%...

conduction loss↗

Levelized-Cost-of-Electricity-Driven Design Optimization for Medium-Voltage Transformerless Photovoltaic Converters: Preprint

Design approaches for power electronics are typically focused on efficiency and power density; however, these strategies do not guarantee cost optimality in any well-defined sense. To overcome this shortcoming, we propose a design framework that yields circuit parameters that minimize the levelized cost of electricity (LCOE) of a generation system. LCOE serves as a meaningful metric since it captures total lifetime costs -- including hardware, balance of system, and maintenance costs\textemdash and includes the impacts of power conversion efficiency and revenue from harvested energy. To obtain a tractable design problem, we formulate an approximate LCOE improvement model that quantifies the changes in LCOE resulting from a candidate converter design. We apply this framework to a multilevel cascaded topology for low-voltage dc to medium-voltage ac conversion without line-frequency transformers. An example 200-kW commercial-scale system is studied and the solution yields a design with 15 cascaded stages, 98.89% efficiency, and an LCOE reduction of 3.6%.

14 SOLAR ENERGY↗

Study of Voltage-Dependent Harmonic Characteristics of Residential Appliances

This paper focuses on the electrical characteristics of residential and domestic appliances and their effects to the power grid. With the ever-changing load landscape and the introduction of power electronics-based equipment and energy-efficient loads, it is increasingly important to have a thorough knowledge of their power quality and harmonic characteristics in addition to conventional load models. This is critical to the accurate load representations, particularly for the complete bottom-up load models, in voltage stability assessment, determining possible interactions at harmonic frequencies, the effect of the system impedance, as well as possible voltage sag and swell and unbalance conditions. For this study, the household appliances are grouped into five categories: lighting, power electronics, resistive, motor, and aggregated loads. The effect of the voltage variation on the load current characteristics is also studied. The results from laboratory experiments involving most of the commonly used domestic appliances are analyzed within a range of +10%/-5% of the nominal supply voltage and within a range of +/-3 Hz of the nominal supply frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗