VETA-1 x ray detection system

The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system.

Podgorski, W. A.

Uniformity and transmission of proportional counter window materials for use with AXAF

The X-ray detection system used to calibrate the Advanced X-ray Astrophysics Facility (AXAF) mirrors will include gas flow and sealed proportional counters. To meet the ultimate 1 percent goal of the calibration project, the transmission and uniformity of the windows must be well known for the soft X-ray wavelengths involved. Various window materials for use with proportional counters are examined for transmission at X-ray wavelengths in the range of 0.1 to 5.9 keV. These include the usual window materials (polypropylene and beryllium), as well as materials only recently employed for detector applications (polyimide and diamond). The transmission uniformity of beryllium at 1.49 keV is examined with a microchannel plate detector, producing a 'shadowgraph' of the window material illuminated with soft X-rays. This technique allows us to investigate nonuniformities on a spatial scale of about .2 mm.

Flanagan, K.

The High Resolution Imaging Instrument for HEAO-B

The High Resolution Imaging Instrument for the HEAO-B X-ray Telescope satellite is designed to reproduce images of celestial X-ray sources in the range of 0.2 to 4.0 keV. It provides both imaging and temporal data. The basic detector is a two-stage microchannel plate with a crossed-grid charge detector. Preamplifiers, detector bias supplies, and some processing circuits are colocated with the detector. The remaining electronic circuits are located in a remote central electronic assembly. The processing system is designed for single-photon processing. The imaging data rate is limited to 100 data points per second. Non-imaging total-field count rate is acquired with a maximum dead time of 14 microseconds per event.

Kubierschky, K.