Engineering Papers⌕ Search

Engineering topics

Ross, John

Publications and source records attributed to Ross, John.

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A COUPLED DETERMINISTIC TRANSPORT CALCULATION IN COMSOL USING PROPER ORTHOGONAL DECOMPOSITION

A coupled physics problem consisting of radiation transport and heat transfer was modeled using COMSOL Multiphysics to simulate a criticality accident. Reduced order models (ROM) were created to accelerate the radiation transport calculation through Proper Orthogonal Decomposition (POD). Additionally, on-the-fly neutron cross sections were generated from a non-linear function through a feed forward neural network. The Livelink for MATLAB module allowed for data transfer between an otherwise independent solver and in-house modules. A data driven approach to POD was developed to act as a surrogate model to couple with heat transfer, with the POD module written in MATLAB coupled to an isolated heat transfer solve in COMSOL. A coupled transient solution resulted in a good approximation of the flux and temperature, with the maximum error being 3E-2 and 2.5E-3 respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗