When are Surface Plasmon Polaritons Excited in the Kretschmann-Raether Configuration?

It is widely believed that the reflection minimum in a Kretschmann-Raether experiment results from direct coupling into surface plasmon polariton modes. Our experimental results provide a surprising discrepancy between the leakage radiation patterns of surface plasmon polaritons (SPPs) launched on a layered gold/germanium film compared to the K-R minimum, clearly challenging this belief. We provide definitive evidence that the reflectance dip in K-R experiments does not correlate with excitation of an SPP mode, but rather corresponds to a particular type of perfectly absorbing (PA) mode. Results from rigorous electrodynamics simulations show that the PA mode can only exist under external driving, whereas the SPP can exist in regions free from direct interaction with the driving field. These simulations show that it is possible to indirectly excite propagating SPPs guided by the reflectance minimum in a K-R experiment, but demonstrate the efficiency can be lower by more than a factor of 3. We find that optimal coupling into the SPP can be guided by the square magnitude of the Fresnel transmission amplitude.

Foley IV, Jonathan J.↗

A compact frequency tunable radio frequency phase shifter with patterned Py enabled transmission line

A well designed frequency tunable phase shifter using patterned Py with different thickness has been demonstrated. Phase shifter is implemented with a slow wave coplanar wave guide (CPW)transmission line, where the signal line has alternate short narrow and wide sections. Py is patterned on the top of narrow section for high inductance density, and inter-digital capacitor is implemented in wide section for high capacitance density. Compared with phase shifter using regular CPW, the dimension of the developed phase shifter has been reduced from 14.86 mm to4.70 mm at 2 GHz. Phase shifter based on 100 nm and 200 nm thick patterned Py with the same dimensions (14lm10lm) are implemented and investigated comprehensively. FMR frequency of 3.2 GHz and 3.6 GHz without any external magnetic field has been achieved for100 nm and 200 nm thick Py film, respectively. Thicker Py has increased inductance density from 1067.2 nH/m to 1193.2 nH/m while the center frequency of the phase shifter has been shifted to 1.80 GHz. Frequency tunability of the phase shifter has been also demonstrated withDC current. The phase shifter can provide 90phase shift continuously from 2 GHz to 1.80 GHz with DC current from 0 mA to 150 mA. As a result, the design concept has great potential in design arbitrary tunable RF components such as filters and couplers.

42 ENGINEERING↗

Application of sub-micrometer patterned permalloy thin film in tunable radio frequency inductors

Electrical tunable meander line inductor using coplanar waveguide structures with patterned permalloy (Py) thin film has been designed and implemented in this paper. High resistivity Si substrate is used to reduce the dielectric loss from the substrate. Inductor is implemented with a 60 nm thick Py deposited and patterned on top of the gold meander line, and Py film is patterned with dimension of 440 nm 10 lm to create the shape anisotropy field, which in turn increases the FMR frequency. Compared to a regular meanderline inductor without the application of sub-micrometer patterned Py thin film, the inductance density has been increased to 20% for the implemented inductor with patterned Py. Measured FMR frequency of the patterned Py is 4.51 GHz without the application of any external magnetic field. This has enabled the inductor application in the practical circuit boards, where the large external magnet is unavailable. Inductance tunability of the implemented inductor is demonstrated by applying a DC current. Applied DC current creates a magnetic field along the hard axis of the patterned Py thin film, which changes the magnetic moment of the thin film and thus, decreases the inductance of the line. Here, the measured results show that the inductance density of the inductor can be varied 5% by applying 300 mA DC current, larger inductance tunability is achievable by increasing the thickness of Py film.

36 MATERIALS SCIENCE↗

Tunable Transmission Line With Nanopatterned Thin Films for Smart RF Applications

A concept of tunable transmission line (TL) enabled with nanopatterned ferromagnetic permalloy (Py) and ferroelectric lead zirconium titanate (PZT) thin films is presented. The permittivity (εr) of PZT is electrical tunable with dc voltage, and the permeability (μr) of Py is electrical tunable with dc current, thus simultaneous electric tunable capacitance and inductance capability are provided for the proposed TL. The proposed TL has been fabricated and compared with a regular line without nanofilm patterns. Py is patterned with the dimensions of 10 μm × 150 nm and thickness of 100 nm for high built-in anisotropy field. The ferromagnetic resonant frequency is measured to be 6.3 GHz. Compared with the regular TL, the implemented TL has only generated 0.05 dB additional insertion loss at 4 GHz. The electrical tunability of both the capacitance and the inductance has been demonstrated for the first time. By applying the varied dc current (0–150 mA) and the dc voltage (0–20 V), measured results have shown that the proposed line can provide 90° phase shift from 3.75 to 4 GHz with the fixed characteristic impedance. The continuous tuning of the characteristics impedance from 59 to 61 under suitable bias conditions shows its promise as an impedance matching network. Tunable range of both the phase shifter and the impedance matching network can be further increased with thicker and multilayer films.

36 MATERIALS SCIENCE↗

Simultaneous topographic and elemental chemical and magnetic contrast in scanning tunneling microscopy

A method and system for performing simultaneous topographic and elemental chemical and magnetic contrast analysis in a scanning, tunneling microscope. The method and system also includes nanofabricated coaxial multilayer tips with a nanoscale conducting apex and a programmable in-situ nanomanipulator to fabricate these tips and also to rotate tips controllably.

47 OTHER INSTRUMENTATION↗

Nitrogen incorporated ultrananocrystalline diamond based field emitter array for a flat-panel x-ray source

A field emission based flat-panel transmission x-ray source is being developed as an alternative for medical and industrial imaging. A field emitter array (FEA) prototype based on nitrogen incorporated ultrananocrystalline diamond film has been fabricated to be used as the electron source of this flat panel x-ray source. The FEA prototype was developed using conventional microfabrication techniques. The field emission characteristics of the FEA prototype were evaluated. Results indicated that emission current densities of the order of 6 mA/cm{sup 2} could be obtained at electric fields as low as 10 V/μm to 20 V/μm. During the prototype microfabrication process, issues such as delamination of the extraction gate and poor etching of the SiO{sub 2} insulating layer located between the emitters and the extraction layer were encountered. Consequently, alternative FEA designs were investigated. Experimental and simulation data from the first FEA prototype were compared and the results were used to evaluate the performance of alternative single and double gate designs that would yield better field emission characteristics compared to the first FEA prototype. The best simulation results are obtained for the double gate FEA design, when the diameter of the collimator gate is around 2.6 times the diameter of the extraction gate.

07 ISOTOPE AND RADIATION SOURCES↗

An easy-to-implement filter for separating photo-excited signals from topography in scanning tunneling microscopy

In order to achieve elemental and chemical sensitivity in scanning tunneling microscopy (STM), synchrotron x-rays have been applied to excite core-level electrons during tunneling. The x-ray photo-excitations result in tip currents that are superimposed onto conventional tunneling currents. While carrying important physical information, the varying x-ray induced currents can destabilize the feedback loop causing it to be unable to maintain a constant tunneling current, sometimes even causing the tip to retract fully or crash. In this paper, we report on an easy-to-implement filter circuit that can separate the x-ray induced currents from conventional tunneling currents, thereby allowing simultaneous measurements of topography and chemical contrasts. The filter and the schematic presented here can also be applied to other variants of light-assisted STM such as laser STM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗