Resolution-enhanced Mapping Spectrometer

A familiar mapping spectrometer implementation utilizes two dimensional detector arrays with spectral dispersion along one direction and spatial along the other. Spectral images are formed by spatially scanning across the scene (i.e., push-broom scanning). For imaging grating and prism spectrometers, the slit is perpendicular to the spatial scan direction. For spectrometers utilizing linearly variable focal-plane-mounted filters the spatial scan direction is perpendicular to the direction of spectral variation. These spectrometers share the common limitation that the number of spectral resolution elements is given by the number of pixels along the spectral (or dispersive) direction. Resolution enhancement by first passing the light input to the spectrometer through a scanned etalon or Michelson is discussed. Thus, while a detector element is scanned through a spatial resolution element of the scene, it is also temporally sampled. The analysis for all the pixels in the dispersive direction is addressed. Several specific examples are discussed. The alternate use of a Michelson for the same enhancement purpose is also discussed. Suitable for weight constrained deep space missions, hardware systems were developed including actuators, sensor, and electronics such that low-resolution etalons with performance required for implementation would weigh less than one pound.

Kumer, J. B.

Low earth orbiting Nadir Etalon Sounding Spectrometer instrument concept for temperature, moisture and trace species, LeoNESS

A concept for a low earth orbiting nadir etalon spectrometer sounder (LeoNESS) is described which can achieve retrieval of temperature, H2O, surface, boundary conditions, cloudiness, and trace species with an accuracy that meets or exceeds the AIRS specifications. Options employing 65-K and 30-K detectors are examined; the former may be implemented via passive radiative cooling. The concept, which is derived from the Cryogenic Limb Array Etalon Spectrometer, has the potential for improving the horizontal and vertical resolution.

Kumer, J. B.

Concept for Geostationary Experimental Temperature and Moisture Sounder (GETMS)

The concept of the Geostationary Experimental Temperature and Moisture Sounder (GETMS) is described, with special attention given to the system constraints and its performance characteristics. The GETMS concept supports operation in a high-resolution 'nominal experimental mode' that could achieve spectral resolution of the order 0.2/cm in the 4.2-micron region with signal/noise sufficient to achieve temperature profile retrievals with vertical resolution of the order 1 to 2 km and accuracy to 1 K or less. The concept includes a cryogenic module to provide cryogenic cooling of the focal plane. The GETMS functional diagram and diagrams of the GETMS spectrometer and of the cryogenics module are included.

Kumer, J. B.

Solc filter engineering

A Solc (1965) filter configuration is presented which is both tunable and spectrally variable, since it possesses an adjustable bandwidth, and which although less efficient than a Lyot filter is attractive because of its spectral versatility. The lossless design, using only an entrance and exit polarizer, improves throughput generally and especially in the IR, where polarizers are less convenient than dichroic sheet polarizers. Attention is given to the transmission profiles of Solc filters with different numbers of elements and split elements, as well as their mechanical design features.

Rosenberg, W. J.

Tunable birefringent filters

This article reviews the types and capabilities of birefringent filters. The general operating principles of Lyot (perfect polarizers), partial polarizing, and Solc (no internal polarizers) filters are introduced. Appropriate techniques for tuning each filter type are presented. Field of view of birefringent filters is discussed and is compared to Fabry-Perot and interference filters. The transmission and throughput advantages of birefringent filters are shown. Finally, the current state of the art in practical filters is reviewed.

Title, A. M.

Tunable birefringent networks

Consideration is given to mechanically tuned birefringent filters for the spectral range 4500-7500 A with bandpasses as narrow as 50 mA and stability of better than 5 mA. Two tuning techniques are described: optical path change and waveplate tuning. The tuning techniques are mechanically simple and require minimal demands on encoders and drive electronics. Tuning to a random wavelength can be accomplished in less than one second while adjacent wavelengths can be reached in a fraction of a second.

Title, A. M.

Effect of channel errors on delta modulation transmission

We have considered the response of a variable step size delta modulator communication system, to errors caused by a noisy channel. For the particular adaptive delta modulation scheme proposed by Song, Garodnick, and Schilling (1971), we have a simple analytic formulation of the output error propagation due to a single channel error. It is shown that single channel errors cause a change in the amplitude and dc level of the output, but do not otherwise affect the shape of the output waveform. At low channel error rates, these effects do not cause any degradation in audio transmission. Higher channel error rates cause overflow or saturation of the step size register. We present relationships between channel error rate, register size, and the probability of register overflow.

Rosenberg, W. J.