Engineering Papers⌕ Search

Engineering topics

Roche, A. E.

Publications and source records attributed to Roche, A. E..

35 records · Page 2

CLAES south-looking aerosol observations for 1992

The Cryogenic Limb Etalon Array Spectrometer (CLAES) aboard the Upper Atmosphere Research Satellite (UARS) has made global observations of stratospheric aerosol during 1992. The instrument and measurement technique are briefly discussed. Samples of CLAES aerosol observations for south-looking days through the course of the Antarctic winter showing evolution of polar stratospheric clouds (PSCs) and the Pinatubo volcanic veil are shown and discussed.

Mergenthaler, J. L.↗

Resolution-enhanced Mapping Spectrometer

A familiar mapping spectrometer implementation utilizes two dimensional detector arrays with spectral dispersion along one direction and spatial along the other. Spectral images are formed by spatially scanning across the scene (i.e., push-broom scanning). For imaging grating and prism spectrometers, the slit is perpendicular to the spatial scan direction. For spectrometers utilizing linearly variable focal-plane-mounted filters the spatial scan direction is perpendicular to the direction of spectral variation. These spectrometers share the common limitation that the number of spectral resolution elements is given by the number of pixels along the spectral (or dispersive) direction. Resolution enhancement by first passing the light input to the spectrometer through a scanned etalon or Michelson is discussed. Thus, while a detector element is scanned through a spatial resolution element of the scene, it is also temporally sampled. The analysis for all the pixels in the dispersive direction is addressed. Several specific examples are discussed. The alternate use of a Michelson for the same enhancement purpose is also discussed. Suitable for weight constrained deep space missions, hardware systems were developed including actuators, sensor, and electronics such that low-resolution etalons with performance required for implementation would weigh less than one pound.

Kumer, J. B.↗

Stratospheric Warmings During February and March 1993

Two stratospheric sudden warmings during February and March 1993 are described using UKMO analyses of height, wind and temperature, PV and diabatic heating calculted from these, and N2O from the CLAES instrument on the UARS.

stratospheric↗

Low earth orbiting Nadir Etalon Sounding Spectrometer instrument concept for temperature, moisture and trace species, LeoNESS

A concept for a low earth orbiting nadir etalon spectrometer sounder (LeoNESS) is described which can achieve retrieval of temperature, H2O, surface, boundary conditions, cloudiness, and trace species with an accuracy that meets or exceeds the AIRS specifications. Options employing 65-K and 30-K detectors are examined; the former may be implemented via passive radiative cooling. The concept, which is derived from the Cryogenic Limb Array Etalon Spectrometer, has the potential for improving the horizontal and vertical resolution.

Kumer, J. B.↗

Geosynchronous orbiting Nadir Etalon Sounding Spectrometer instrument concept for temperature, moisture and trace species, GeoNESS

The paper describes the salient features of the Geosynchronous orbiting Nadir Etalon Sounding Spectrometer (GeoNESS) designed for applications from geosynchronous orbit for nadir sounding temperature, moisture, and trace species analyses in the troposphere and the lower stratosphere. Particular attention is given to the optics of GeoNESS, the optomechanical design, the cooling systems, the measurement approach used in GeoNESS, the channel selection, and the calibration considerations.

Kumer, J. B.↗

Concept for obtaining geostationary limb infrared measurements (GEOLIM) and their application

The scientific value and utility of including the capability for spectral earthlimb emission measurements in an advanced geostationary mission is discussed. These measurements are expected to support improved scientific understanding of the atmospheric region extending from the tropospheric cloud tops up to the thermosphere. Specific topics in the science of this region that are addressed by geostationary observations of spectral earthlimb emission are discussed. For many of these topics, nadir sounding measurements are either at great disadvantage or completely inappropriate. A promising approach for acquiring the earthlimb measurements, and a preliminary instrument concept are discussed.

Kumer, J. B.↗

CLAES focal plane array

The Cryogenic Limb Array Etalon Spectrometer for the NASA Upper Atmospheric Research Satellite uses solid-state focal plane arrays to detect emission from the earth's atmosphere over the IR wavelength range 3.5 to 13 microns. This paper discusses the design of the focal plane detector assembly and compares calculated performance with measurements. Measurements were made of focal plane noise and responsivity as functions of frequency (2 to 500 Hz) and temperature (12 to 19 K), pixel-to-pixel and across-array crosstalk, and linearity over a dynamic range of 100,000. The measurements demonstrate that the arrays satisfy the science requirements, and that, in general, there is reasonable agreement between the measurements and the analytical model.

Roche, A. E.↗

Model calculations of spectral transmission for the CLAES etalons

This paper describes models for calculating spectral transmission for the Cryogenic-Limb-Array-Etalon-Spectrometer (CLAES) etalons. These models involve a convolution of the Airy function for a given thickness with the distribution of surface thicknesses, the effect of absorption in the substrate, and the field of view broadening as a function of etalon tilt angle. A comparison of model calculations with experimental transmission data for CLAES etalons centered at 3.52, 5.72, 8.0, and 11.86 microns showed that these models are able to provide a good description of the CLAES etalons.

James, T. C.↗

Concept for Geostationary Experimental Temperature and Moisture Sounder (GETMS)

The concept of the Geostationary Experimental Temperature and Moisture Sounder (GETMS) is described, with special attention given to the system constraints and its performance characteristics. The GETMS concept supports operation in a high-resolution 'nominal experimental mode' that could achieve spectral resolution of the order 0.2/cm in the 4.2-micron region with signal/noise sufficient to achieve temperature profile retrievals with vertical resolution of the order 1 to 2 km and accuracy to 1 K or less. The concept includes a cryogenic module to provide cryogenic cooling of the focal plane. The GETMS functional diagram and diagrams of the GETMS spectrometer and of the cryogenics module are included.

Kumer, J. B.↗

CLAES blocker filter rejection requirements

Some details of the calculations of out-of-band spectral rejection requirements for the CLAES blocker filters are described. For a particular blocker centered within an etalon bandpass, the signal to be expected when a particular etalon transmission peak is centered at the central wavelength of the blocker filter is calculated. This signal is compared with the total signal arising from all other transmission peaks within the etalon bandpass and all of the radiation from the entire spectrum outside of the etalon bandpass. The results for a few of the blocker filters are listed, and the design goals are compared with theoretical design results.

James, T. C.↗

Spectroscopic database

Several aspects of quantitative atmospheric spectroscopy are considered, using a classification of the molecules according to the gas amounts in the stratosphere and upper troposphere, and reviews of quantitative atmospheric high-resolution spectroscopic measurements and field measurements systems are given. Laboratory spectroscopy and spectral analysis and prediction are presented with a summary of current laboratory spectroscopy capabilities. Spectroscopic data requirements for accurate derivation of atmospheric composition are discussed, where examples are given for space-based remote sensing experiments of the atmosphere: the ATMOS (Atmospheric Trace Molecule) and UARS (Upper Atmosphere Research Satellite) experiment. A review of the basic parameters involved in the data compilations; a summary of information on line parameter compilations already in existence; and a summary of current laboratory spectroscopy studies are used to assess the data base.

Husson, N.↗

Performance analysis for the cryogenic etalon spectrometer on the Upper Atmospheric Research Satellite

The Upper Atmospheric Research Satellite (UARS) program has the objective of providing an 18-month to 2-year platform for observations of the upper atmosphere, giving particular attention to the stratosphere, mesosphere, and lower thermosphere. The primary aims of the mission are related to the measurement of the solar energy input between 120 and 500 km, the acquisition of global maps of the vertical and horizontal distribution of a series of critical trace and minor species, and the investigation of the dynamics of the upper atmosphere. One of several instruments designed to perform neutral species measurements on board the satellite is the Cryogenic Limb Array Etalon Spectrometer (CLAES). The CLAES experiment is concerned with measurements of concentrations of species of interest to the ozone layer balance. Attention is given to the performance requirements of the instrument and the effects of these requirements on the cryogenic design.

Roche, A. E.↗

Two-year solid hydrogen cooler for the Cryogenic Limb Array Etalon Spectrometer (CLAES) instrument

The Cryogenic Limb Array Etalon Spectrometer (CLAES) will be one of thirteen instruments on board the Upper Atmospheric Research Satellite (UARS) in late 1988. CLAES is to be employed for the measurement of stratospheric trace species concentrations affecting the ozone layer balance. It is an earth-limb viewing instrument which requires cryogenic cooling in order to obtain the necessary performance sensitivity. The present investigation is concerned with the solid hydrogen cryogen subsystem which provides the instrument temperature needed. Attention is given to the studies which led to the selection of solid hydrogen as cooling agent, the baseline cooler system, aspects of baseline performance sensitivity, and nominal cooler operations.

Naes, L. G.↗

Telescope-optical system performance analysis for the Cryogenic Limb Array Etalon Spectrometer (CLAES) on the Upper Atmospheric Research Satellite

A first-order performance analysis of the CLAES telescope-optical system is presented. The experiment involves the passive measurement of earth-limb radiance over a 10-60 km tangent altitude range, and is based on a solid Fabry-Perot spectrometer which provides spectral resolution of 0.25/cm for atmospheric emission spectroscopy over the 3.5-12 micron IR range. The optical system is required to provide a high degree of off-axis rejection and stray-light control, primarily to suppress intense emission from the earth surface. The astigmatism and other geometric aberrations are corrected by a secondary mirror which produces an excellent image of the primary one, allowing for location of a diffraction control or Lyot stop. The off-axis scattering performance of the telescope is examined in terms of the mirror scatter coefficient and point source rejection ratio. A mirror bidirectional reflectance distribution function of 0.0001 at 1 deg with a 1/theta-squared roll-off between 1 and 0.2 deg is realizable based on recent measurements. This results in an off-axis radiance term that is generally small in comparison with the system-limiting NER.

Roche, A. E.↗

Airborne observations of methane in Comet Kohoutek

The experiment is described for airborne observations of Comet Kohoutek using an infrared tilting-filter photometer. Preliminary analysis of the data established an upper limit to the Comet's fluorescence radiation in methane lines at 3.3 microns.

Roche, A. E.↗

Absolute rate constant for the O plus NO chemiluminescence in the near infrared

Infrared chemiluminescence from the process O + NO (+M) NO2 + hv (+M) has been studied between 1.3 and 4.1 micrometer. The wavelength dependence of the continuum between 1.3 and 3.3 micrometer is in fair agreement with previous studies and the measured radiative rate constant at 1.51 micrometer establishes the NO-O glow in this spectral range as a secondary emission standard. Comparison with previous studies of the visible region of the glow implies that the overall radiative rate constant lies in the range (9.4 to 11.2) x 10 to the minus 17 power cu cm sec/1. In the region 3.3 to 4.1 micrometer, the previously observed broad band, peaking at 3.7 micrometer, shows a complex kinetic dependence on O and M.

Golde, M. F.↗