Engineering Papers⌕ Search

Engineering topics

Roberts, K

Publications and source records attributed to Roberts, K.

SU-C-BRD-05: Non-Invasive in Vivo Biodosimetry in Radiotherapy Patients Using Electron Paramagnetic Resonance (EPR) Spectroscopy

Purpose: Medical intervention following a major, unplanned radiation event can elevate the human whole body exposure LD50 from 3 to 7 Gy. On a large scale, intervention cannot be achieved effectively without accurate and efficient triage. Current methods of retrospective biodosimetry are restricted in capability and applicability; published human data is limited. We aim to further develop, validate, and optimize an automated field-deployable in vivo electron paramagnetic resonance (EPR) instrument that can fill this need. Methods: Ionizing radiation creates highly-stable, carbonate-based free radicals within tooth enamel. Using a process similar to nuclear magnetic resonance, EPR directly measures the presence of radiation-induced free radicals. We performed baseline EPR measurements on one of the upper central incisors of total body irradiation (TBI) and head and neck (H&N) radiotherapy patients before their first treatment. Additional measurements were performed between subsequent fractions to examine the EPR response with increasing radiation dose. Independent dosimetry measurements were performed with optically-stimulated luminescent dosimeters (OSLDs) and diodes to more accurately establish the relationship between EPR signal and delivered radiation dose. Results: 36 EPR measurements were performed over the course of four months on two TBI and four H & N radiotherapy patients. We observe a linear increase in EPR signal with increasing dose across the entirety of the tested range. A linear least squares-weighted fit of delivered dose versus measured signal amplitude yields an adjusted R-square of 0.966. The standard error of inverse prediction (SEIP) is 1.77 Gy. For doses up to 7 Gy, the range most relevant to triage, we calculate an SEIP of 1.29 Gy. Conclusion: EPR spectroscopy provides a promising method of retrospective, non-invasive, in vivo biodosimetry. Our preliminary data show an excellent correlation between predicted signal amplitude and delivered dose. With further development, a robust means of predicting delivered radiation dose from EPR measurements is expected. This project was funded by the Biomedical Advanced Research and Development Authority (BARDA) within the U.S. Department of Health and Human Services subcontracted through the Geisel School of Medicine at Dartmouth and by the Dartmouth Physically-Based Biodosimetry Center for Medical Countermeasures Against Radiation (Dart-Dose CMCR) Pilot Program.

60 APPLIED LIFE SCIENCES↗

The GALAXIE all-optical FEL project

We describe a comprehensive project, funded under the DARPA AXiS program, to develop an all-optical table-top X-ray FEL based on dielectric acceleration and electromagnetic undulators, yielding a compact source of coherent X-rays for medical and related applications. The compactness of this source demands that high field (>GV/m) acceleration and undulation-inducing fields be employed, thus giving rise to the project's acronym: GV/m AcceLerator And X-ray Integrated Experiment (GALAXIE). There are numerous physics and technical hurdles to surmount in this ambitious scenario, and the integrated solutions include: a biharmonic photonic TW structure, 200 micron wavelength electromagnetic undulators, 5 {mu}m laser development, ultra-high brightness magnetized/asymmetric emittance electron beam generation, and SASE FEL operation. We describe the overall design philosophy of the project, the innovative approaches to addressing the challenges presented by the design, and the significant progress towards realization of these approaches in the nine months since project initialization.

43 PARTICLE ACCELERATORS↗

MOBILIZATION AND CHARACTERIZATION OF COLLOIDS GENERATED FROM CEMENT LEACHATES MOVING THROUGH A SRS SANDY SEDIMENT

Naturally occurring mobile colloids are ubiquitous and are involved in many important processes in the subsurface zone. For example, colloid generation and subsequent mobilization represent a possible mechanism for the transport of contaminants including radionuclides in the subsurface environments. For colloid-facilitated transport to be significant, three criteria must be met: (1) colloids must be generated; (2) contaminants must associate with the colloids preferentially to the immobile solid phase (aquifer); and (3) colloids must be transported through the groundwater or in subsurface environments - once these colloids start moving they become 'mobile colloids'. Although some experimental investigations of particle release in natural porous media have been conducted, the detailed mechanisms of release and re-deposition of colloidal particles within natural porous media are poorly understood. Even though this vector of transport is known, the extent of its importance is not known yet. Colloid-facilitated transport of trace radionuclides has been observed in the field, thus demonstrating a possible radiological risk associated with the colloids. The objective of this study was to determine if cementitious leachate would promote the in situ mobilization of natural colloidal particles from a SRS sandy sediment. The intent was to determine whether cementitious surface or subsurface structure would create plumes that could produce conditions conducive to sediment dispersion and mobile colloid generation. Column studies were conducted and the cation chemistries of influents and effluents were analyzed by ICP-OES, while the mobilized colloids were characterized using XRD, SEM, EDX, PSD and Zeta potential. The mobilization mechanisms of colloids in a SRS sandy sediment by cement leachates were studied.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser-matter Interaction with Submerged Samples

With the long-term goal in mind of investigating if one could possibly design a 'universal solid-sample comminution technique' for debris and rubble, we have studied pulsed-laser ablation of solid samples that were contained within a surrounding fluid. Using pulses with fluences between 2 J and 0.3 J, wavelengths of 351 and 527 nm, and samples of rock, concrete, and red brick, each submerged in water, we have observed conditions in which {micro}m-scale particles can be preferentially generated in a controlled manner, during the laser ablation process. Others have studied laser peening of metals, where their attention has been to the substrate. Our study uses non-metallic substrates and analyzes the particles that are ablated from the process. The immediate impact of our investigation is that laser-comminution portion of a new systems concept for chemical analysis has been verified as feasible.

36 MATERIALS SCIENCE↗

REDUCTION CAPACITY OF SALTSTONE AND SALTSTONE COMPONENTS

The duration that saltstone retains its ability to immobilize some key radionuclides, such as technetium (Tc), plutonium (Pu), and neptunium (Np), depends on its capacity to maintain a low redox status (or low oxidation state). The reduction capacity is a measure of the mass of reductants present in the saltstone; the reductants are the active ingredients that immobilize Tc, Pu, and Np. Once reductants are exhausted, the saltstone loses its ability to immobilize these radionuclides. The reduction capacity values reported here are based on the Ce(IV)/Fe(II) system. The Portland cement (198 {micro}eq/g) and especially the fly ash (299 {micro}eq/g) had a measurable amount of reduction capacity, but the blast furnace slag (820 {micro}eq/g) not surprisingly accounted for most of the reduction capacity. The blast furnace slag contains ferrous iron and sulfides which are strong reducing and precipitating species for a large number of solids. Three saltstone samples containing 45% slag or one sample containing 90% slag had essentially the same reduction capacity as pure slag. There appears to be some critical concentration between 10% and 45% slag in the Saltstone formulation that is needed to create the maximum reduction capacity. Values from this work supported those previously reported, namely that the reduction capacity of SRS saltstone is about 820 {micro}eq/g; this value is recommended for estimating the longevity that the Saltstone Disposal Facility will retain its ability to immobilize radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generalized gamma-ray isotopic analysis software and re-evaluation of the two important 242Pu branching ratios

The goal of the generalized gamma-ray analysis software is to provide precise and accurate isotopic analyses of samples that do not have a standard experimental geometry. This analysis tool will analyze gamma-ray data from all types of measurement scenarios with little or no interaction from the user. This tool also provides complete transparency regarding the gamma-ray peaks and branching intensities used in the analysis with the capability for the user to modify this information. They are currently at the data collected phase of building a validated spectral library. One of the by-products in this data collection phase is enabling them to reevaluate the two important branching ratios in {sup 242}Pu. These branching ratios are required for very high burn-up plutonium fuels. The preliminary analysis shows that the energy of the states are 103.5 keV and 158.82 keV, the branching ratio are 1.36E-5 (9%) and 3.37E-6(7%), respectively. More accurate measurements and analysis are currently being carried out.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

R-values

I'll try to keep this short and simple. R{sub LANL} = (beta cpm of X{sub exp} on system 'A')/ (beta cpm of {sup 99}Mo{sub exp} on system 'A')/ (beta cpm of X on system 'A', from thermal on {sup 235}U)/ (beta cpm of {sup 99}Mo on system 'A', from thermal on {sup 235}U). As I understand it, the above equation is the historical (as well as current) way of determining R-values using data from beta counting at LANL. The ratio in the denominator, a little 'r', is the 'baseline' or 'calibration' value for a specific beta detector. Over time, if the detector 'drifts' one would see a variation in this 'r' during a thermal calibration measurement. This baseline is what LANL likes to track to monitor specific detector performance - this is not relevant to LLNL where gamma detection is used for determining R-values. LANL states that uncertainty is only dependent upon the count statistics for the isotopes measured. If one tries to convert this to an atom basis, the uncertainties will increase due to the incorporation of the uncertainties in the nuclear data used to convert the cpm to atoms. LLNL switched to gamma detection methods in the 1970s thus replacing our beta counting effort. The equation below is how we have since determined R-values. The numerator ratios atom values of isotopes that are determined by measuring gamma cpm (usually? using several peaks per isotope) and then converting to particle decay in dpm using detector efficiency for each peak and the appropriate branch ratio for each gamma emission. Isotope decay is then converted to atoms using specific activity, mass or volume?, and Avogadro's number. The denominator is simply the ratio of published, cumulative fission product chain yields for isotopes produced in a thermal irradiation on 235U - values of England & Ryder are used by LLNL for the NTNF program. Uncertainties in LLNL R-values are dependent upon gamma counting statistics as well as the nuclear data for each isotope. R{sub LLNL} = (Atoms of X{sub exp})/(Atoms of {sup 99}Mo{sub exp})/(Cumulative Fission Chain Yield of X, from thermal on {sup 235}U)/(Cumulative Fission Chain Yield of {sup 99}Mo, from thermal on {sup 235}U). The next page tabulates fission chain yields and 'atoms per gram' amounts measured in a recent NTNF Thermal Calibration. The R-values in the table are calculated using the LLNL method of determining R. The measure of success is demonstrated by how close to 1.00 the R-value is when determined during a Thermal Calibration. A value of 1.00 is the desired value. In the example below, only four isotopes lie outside of 1.00 by more than 3 percent. These are the four isotopic measurements that obviously need to be improved.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗