Engineering Papers⌕ Search

Engineering topics

Roberts, B. L.

Publications and source records attributed to Roberts, B. L..

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The fast non-ferric kicker system for the Muon g–2 Experiment at Fermilab

Here we describe the installation, commissioning, and characterization of the new injection kicker system in the Muon g – 2 Experiment (E989) at Fermilab, which makes a precision measurement of the muon magnetic anomaly. Three Blumlein pulsers drive each of the 1.27-m-long non-ferric kicker magnets, which reside in a storage ring vacuum (SRV) that is subjected to a 1.45 T magnetic field. The new system has been redesigned relative to Muon g – 2 ’s predecessor experiment, and we present those details in this manuscript.

43 PARTICLE ACCELERATORS↗

The Measurement of the Anomalous Magnetic Moment of the Muon at Fermilab

The anomalous magnetic moment of the muon is one of the most precisely measured quantities in experimental particle physics. Its latest measurement at Brookhaven National Laboratory deviates from the Standard Model expectation by approximately 3.5 standard deviations. The goal of the new experiment, E989, now under construction at Fermilab, is a fourfold improvement in precision. Here in this article, we discuss the details of the future measurement and its current status.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mu2e Conceptual Design Report

Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon capture rates on O-16 leading to bound states of N-16.

A low-energy spectrum of gamma-rays following muon capture in O-16 was obtained with a high-resolution 1 cu cm Ge(Li) detector. The graph of the spectrum shows the separation of contaminant peaks from the 120 keV N-16 line. It is pointed out that there is a large discrepancy between the capture rate obtained in the investigation and results reported by Deutsch et al. (1969).

Kane, F. R.↗