Characterizing Electrical Arc Behavior in Ion Engines
Test results using an engineering model Advanced NEXT thruster are presented to identify different arc types utilizing ground test hardware. Three distinct arc types were observed: grid-to-grid arcs, high voltage-to-chassis arcs, and a combination of both. The frequency of high voltage-to-chassis arcs ranged from 4-30%, depending on operating conditions and hardware configuration. Higher beam currents were typically associated with more frequent high voltage-to-chassis arcs. During these arcs, the measured chassis current levels ranged from 20-70 A, however a significant portion of the output beam current returned to the beam supply via the neutralizer cathode plasma, which may be a ground test facility effect. The paper also discusses conducted susceptibility tests that can be performed at the spacecraft level to address the transients associated with arcing events.