THE NEW DESIGN FOR CAPTURE CAVITY OF CEBAF

In CEBAF, the electron beam from the injector must be sufficiently relativistic to match a 1 GeV recirculated beam in the first linac. The electron beam is produced with a ~130 keV electron gun, then accelerated by a room temperature, graded-beta standing wave linac, capture section, from 130 keV to 510 keV before enters two 5-cell superconducting RF cavities for further acceleration. Present capture cavity is a 5-cell side-coupled cavity. We designed a new slot-coupled cavity which has lower power consumption and more compact size.

Wang, Shaoheng↗

Field Emission and Consequences as Observed and Simulated for CEBAF Upgrade Cryomodules

High gamma and neutron radiation levels were monitored at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) after installation of new cavity cryomodules and initial test runs in the frame of the ongoing 12 GeV upgrade program. The dose rates scaled exponentially with cavity accelerating fields, but were independent of the presence of an electron beam in the accelerator. Hence, field emission (FE) is the source of origin. This has led to concerns regarding the high field operation (100 MV per cryomodule) in the future 12 GeV era. Utilizing supercomputing, novel FE studies have been performed with electrons tracked through a complete cryomodule. It provides a principal understanding of experimental observations as well as ways to mitigate FE as best as practicable by identification of problematic cavities.

Marhauser, Frank↗

Fabrication and Testing of Deflecting Cavities for APS

Jefferson Lab (Newport News, Virginia) in collaboration with Argonne National Laboratory (Argonne, IL) has fabricated and tested four first article, 2.8 GHz, deflecting SRF cavities, for Argonne's Short-Pulse X-ray (SPX) project. These cavities are unique in many ways including the fabrication techniques in which the cavity cell and waveguides were fabricated. These cavity subcomponents were milled from bulk large grain niobium ingot material directly from 3D CAD files. No forming of sub components was used with the exception of the beam-pipes. The challenging cavity and helium vessel design and fabrication results from the stringent RF performance requirements required by the project and operation in the APS ring. Production challenges and fabrication techniques as well as testing results will be discussed in this paper.

Mammosser, John↗

Update on the R&D of vertical buffered electropolishing on Nb samples and SRF single cell cavities

Electropolishing (EP) has become a popular choice as the final step of the surface removal process during the fabrication of Nb superconducting radio frequency (SRF) cavities. One of the major reasons for the choice is that Nb SRF cavities treated by EP tend to have a better chance to reach an accelerating gradient of 30 MV/m or higher than those treated by buffered chemical polishing (BCP). This advantage of EP over BCP can at least be partially attributed to the smoother Nb surfaces that EP can produce. Recently a Nb surface removal technique called buffered electropolishing (BEP) was developed at JLab. The root mean square of the Nb surfaces treated by BEP can be as smooth as 20nm over a surface area of 200X200 ?m2. In this contribution, R&D efforts of vertical BEP on Nb small flat samples and SRF single cell cavities since the last SRF conference in 2009 will be updated. It is shown that under a suitable condition, BEP can have a Nb removal rate as high as 10 ?m/mim that is more than 25 and 5 times quicker than those of EP and BCP(112) respectively. Possible mechanisms responsible for the high Nb removal rate are proposed. Clues on the optimization of vertical BEP and EP treatments on Nb SRF cavities from recent experimental results obtained on a Nb single cell demountable cavity will be discussed.

Wu, Andy↗

EFFECTS OF CATHODE SHAPES ON BEP AND EP DURING VERTICAL SURFACE TREATMENTS ON NIOBIUM

Minimization of field emission on the inner surfaces of niobium (Nb) superconducting radio frequency (SRF) cavities is highly desirable for SRF community. Previous experimental results [1] seemed to imply that the threshold of field emission was related to the thickness of Nb surface oxide layers. In this contribution, a more detailed study on the influences of the surface oxide layers on the field emission on Nb surfaces will be reported. By anodization technique, the thickness of the surface pentoxide layer was varied from 3nm up to 460nm. These samples were measured by means of a home-made scanning field emission microscope (SFEM). The emitters detected by SFEM were characterized using a scanning electron microscope together with an energy dispersive x-ray analyzer. Attempts were made to try to correlate the results from SFEM measurements with surface morphology and oxide thickness of Nb samples and chemical composition and geographic shape of the emitters. The SFEM results were also analyzed employing a model based on the classic electromagnetic theory. Possibly implications for Nb SRF cavity applications from this study will be discussed. 1: A.T. Wu et al, Proceedings of IPAC 2010, Kyoto, Japan, WEPEC081

Wu, Andy↗

Coherent Electron Cooling Demonstration Experiment

Coherent electron cooling (CEC) is considered to be on of potential candidates capable of cooling high-energy, high-intensity hadron beams to very small emittances. It also has a potential to significantly boost luminosity of high-energy hadron-hadron and electron-hadron colliders. In a CEC system, a perturbation of the electron density caused by a hadron is amplified and fed back to the hadrons to reduce the energy spread and the emittance of the beam. Following the funding decision by DoE office of Nuclear Physics, we are designing and building coherent electron cooler for a proof-of-principle experiment at RHIC to cool 40 GeV heavy ion beam. In this paper, we describe the layout of the CeC installed into IP2 interaction region at RHIC. We present the design of the CeC cooler and results of preliminary simulations.

Litvinenko, Vladimir N.↗

X-ray Sources by Energy Recovered Linacs and Their Needed R&D

In this paper we review the current state of research on energy recovered linacs as drivers for future X-ray sources. For many types of user experiments, such sources may have substantial advantages compared to the workhorse sources of the present: high energy storage rings. Energy recovered linacs need to be improved beyond present experience in both energy and average current to support this application. To build an energy recovered linac based X-ray user facility presents many interesting challenges. We present summaries on the Research and Development (R&D) topics needed for full development of such a source, including the discussion at the Future Light Sources Workshop held in Gaithersberg, Maryland on September 15-17, 2009. A first iteration of an R&D plan is presented that is founded on the notion of building a set of succeedingly larger test accelerators exploring cathode physics, high average current injector physics, and beam recirculation and beam energy recovery at high average current. Our basic conclusion is that a reviewable design of such a source can be developed after an R&D period of reasonably short duration.

43 PARTICLE ACCELERATORS↗

Development of a CW NCRF Photoinjector using Solid Freeform Fabrication (SFF)

A key issue for high average power, normal conducting radio frequency (NCRF), photoinjectors is efficient structure cooling. To that end, RadiaBeam has been developing the use of Solid Freeform Fabrication (SFF) for the production of NCRF photoinjectors. In this paper we describe the preliminary design, developed in collaboration with JLab, of a high gradient, very high duty cycle, photoinjector combining the cooling efficiency only possible through the use of SFF, and the RF efficiency of a re-entrant gun design. Simulations of the RF and thermal-stress performance are presented, as well as material testing of SFF components.

43 PARTICLE ACCELERATORS↗

PROSPECTS FOR A VERY HIGH POWER CW SRF LINAC

Steady development in SRF accelerator technology combined with the success of large scale installations such as CEBAF at Jefferson Laboratory and the SNS Linac at ORNL gives credibility to the concept of very high average power CW machines for light sources or Proton drivers. Such machines would be powerful tools for discovery science in themselves but could also pave the way to reliable cost effective drivers for such applications as neutrino factories, an energy-frontier muon collider, nuclear waste transmutation or accelerator driven subcritical reactors for energy production. In contrast to machines such as ILC that need maximum accelerating gradient, the challenges in these machines are mainly in efficiency, reliability, beam stability, beam loss and of course cost. In this paper the present state of the art is briefly reviewed and options for a multi-GeV, multi-MW CW linac are discussed.

43 PARTICLE ACCELERATORS↗

Novel Geometries for the LHC Crab Cavity

The planned luminosity upgrade to LHC is likely to necessitate a large crossing angle and a local crab crossing scheme. For this scheme crab cavities align bunches prior to collision. The scheme requires at least four such cavities, a pair on each beam line either side of the interaction point (IP). Upstream cavities initiate rotation and downstream cavities cancel rotation. Cancellation is usually done at a location where the optics has re-aligned the bunch. The beam line separation near the IP necessitates a more compact design than is possible with elliptical cavities such as those used at KEK. The reduction in size must be achieved without an increase in the operational frequency to maintain compatibility with the long bunch length of the LHC. This paper proposes a suitable superconducting variant of a four rod coaxial deflecting cavity (to be phased as a crab cavity), and presents analytical models and simulations of suitable designs.

43 PARTICLE ACCELERATORS↗

Paper High power RF tests on WR650 pre-stressed planar windows

A new planar, ceramic window intended to be used with WR650 waveguide fundamental power couplers at 1300 MHz or 1500 MHz has been developed. It is based on the pre-stressed planar window concept tested in PEP II and LEDA. A test stand that made use of the 100kW CW 1500 MHz RF system in the JLAB FEL was commissioned and used to apply up to 80 kW traveling wave (TW)to the windows. Two different types of RF windows (brazed and diffusion bonded ceramics) with design specification of 50 kW CW in TW mode were successfully tested both as a gas barrier (intended to operate up to 2 psi) and as a vacuum barrier. The vacuum windows were able to maintain UHV quality vacuum and were successfully operated in the 10-9 mbar range. An overview of the pre-stressed power windows, RF test stand, procedures and RF power testing results will be presented.

Stirbet, Mircea↗

JLAB UPGRADE AND HIGH CURENT CAVITY DEVELOPMENTS

We present the status and recent results from the development of new SRF cavities for the CEBAF 12 GeV upgrade and for future light source applications. The JLab 12 GeV upgrade requires ten new high-performance CW cryomodules. These will each contain eight seven-cell cavities of a "low-loss" design with HOM damping sufficient for ~1mA of continuous current. Jlab has fabricated and tested a number of such cavities and demonstrated compliance with all 12 GeV project requirements with conventional BCP cavity processing. Recently we have also electro-polished several cavities of this type and shown significantly better performance than the standard BCP. This processing method could provide improved operational margin and lower cryogenic loads at the CEBAF working point. For future light source applications such as FELs or ERLs, cavities with higher beam current capability are desirable. Jlab has developed a high-current cavity for such applications with a cell shape optimized to minimize HOM power extraction and maximize the BBU threshold. We report on the latest tests of this design and on plans to assemble a two-cavity cryomodule for testing with beam in the recirculation loop of the JLab FEL.

Preble, Joseph↗

Rugged Ceramic Window for RF Applications

High-current RF cavities that are needed for many accelerator applications are often limited by the power transmission capability of the pressure barriers (windows) that separate the cavity from the power source. Most efforts to improve RF window design have focused on alumina ceramic, the most popular historical choice, and have not taken advantage of new materials. Alternative window materials have been investigated using a novel Merit Factor comparison and likely candidates have been tested for the material properties which will enable construction in the self-matched window configuration. Window assemblies have also been modeled and fabricated using compressed window techniques which have proven to increase the power handling capability of waveguide windows. Candidate materials have been chosen to be used in fabricating a window for high power testing at Thomas Jefferson National Accelerator Facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigations on Absorber Materials at Cryogenic Temperatures

In the framework of the 12 GeV upgrade project for the Continuous Electron Beam Accelerator Facility (CEBAF) improvements are being made to refurbish cryomodules housing Thomas Jefferson National Accelerator Facility's (JLab) original 5-cell cavities. Recently we have started to look into a possible simplification of the existing Higher Order Mode (HOM) absorber design combined with the aim to find alternative material candidates. The absorbers are implemented in two HOM-waveguides immersed in the helium bath and operate at 2 K temperature. We have built a cryogenic setup to perform measurements on sample load materials to investigate their lossy characteristics and variations from room temperature down to 2 K. Initial results are presented in this paper.

43 PARTICLE ACCELERATORS↗

HOM Survey of the First CEBAF Upgrade Style Cavity Pair

The planned upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Laboratory (JLab) requires ten new superconducting rf (SRF) cavity cryomodules to double the beam energy to the envisaged 12 GeV. Adequate cavity Higher Order Mode (HOM) suppression is essential to avoid multipass, multibunch beam break-up (BBU) instabilities of the recirculating beam. We report on detailed HOM surveys performed for the first two upgrade style cavities tested in a dedicated cavity pair cryomodule at 2K. The safety margin to the BBU threshold budget at 12 GeV has been assessed.

43 PARTICLE ACCELERATORS↗

STATUS AND TEST RESULTS OF HIGH CURRENT 5-CELL SRF CAVITIES DEVELOPED AT JLAB

The development of a new compact CW cryomodule for use in future Energy Recovery Linacs (ERLs) and Free Electron Lasers (FELs) is underway at JLab with the objective of transporting beam current up to Ampere-levels. Design goals include broadband cavity Higher Order Mode (HOM) damping, HOMs tuned to safe frequencies to minimize the power extracted from the beam, good real-estate gradient and cryogenic efficiency and consideration of cost and maintainability. Two 1497 MHz high current niobium five-cell cavities with waveguide end groups have been manufactured recently. We report on the latest results including high field tests in a vertical Dewar at 2K and a detailed assessment of the impedance budget for beam breakup (BBU) instability. The general cryomodule and cavity concept is described as well.

43 PARTICLE ACCELERATORS↗