Engineering Papers⌕ Search

Engineering topics

Riestenberg, David

Publications and source records attributed to Riestenberg, David.

At least 91 records · Page 5

CO 2 Procurement Plan and Agreement (SECARB Phase III Work Product 7.2.1.a)

The Southeast Regional Carbon Sequestration Partnership’s (SECARB) Anthropogenic Test is a demonstration of the deployment of CO 2 capture, transport, geologic storage and monitoring technologies. The capture component of the test takes place at the James M. Barry Electric Generating Plant in Bucks, Alabama. The capture facility utilizes post-combustion amine capture technology licensed from Mitsubishi Heavy Industries America to process flue gas from a coal-fired power unit at Plant Barry. The amount of CO 2 captured using this process is equivalent to the emissions produced when generating 25 megawatts (MW) of electricity. CO 2 captured at the plant is transported by pipeline for underground storage in a saline geologic formation within the Citronelle Dome. This project is one of the first and the largest fully-integrated commercial prototype coal-fired carbon capture and storage projects in the US. This report will highlight the essential pieces necessary to bring CO 2 from the capture facility at Plant Barry to the Anthropogenic Test Site. They are: 1) the capture facility, 2) the pipeline and 3) the well site injection equipment.

01 COAL, LIGNITE, AND PEAT↗

Site Design and Layout In Preparation for the Anthropogenic Test (SECARB Work Product 6.2.1.b)

Commercial-scale carbon capture and storage (CCS) technology deployment for the electrical utility industry will require a robust international R&D program with governmental support both in cost-share and in risk management. In an effort to comply with environmental legislation or regulation related to CO 2 , the electrical utility industry hopes to be in a position to make financial decisions on utility boiler sourced CCS technology and associated risk management by 2020.

01 COAL, LIGNITE, AND PEAT↗

Completed Drilling Permit (SECARB Phase III Work Product 3.2.6.a)

The Southeast Regional Carbon Sequestration Partnership’s (SECARB’s) Anthropogenic Test is a demonstration of the deployment of CO 2 capture, transport, geologic storage, and monitoring technologies. The capture component of the test takes place at the James M. Barry Electric Generating Plant in Bucks, Alabama. The capture facility utilizes post-combustion amine capture technology licensed from Mitsubishi Heavy Industries America to process flue gas from a coal-fired power unit at Plant Barry. The amount of CO 2 captured using this process is equivalent to the emissions produced when generating 25 megawatts (MW) of electricity. CO 2 captured at the plant is transported by pipeline for underground storage in a saline geologic formation within the Citronelle Dome. This project is one of the first and the largest fully-integrated commercial prototype coal-fired carbon capture and storage projects in the USA.

01 COAL, LIGNITE, AND PEAT↗

SECARB Phase III Anthropogenic Test Site Implementation Plan

As part of the Southeastern Regional Carbon Sequestration Partnership’s (SECARB) Phase III initiative, a test site and anthropogenic carbon dioxide (CO 2 ) source have been selected for a large-scale demonstration of CO 2 separation, capture and sequestration in southwestern Alabama. The project, referred to as the Anthropogenic Test, represents a major step toward demonstrating the viability of integrating carbon capture and storage to mitigate climate change. The CO 2 storage project will inject CO 2 captured from Alabama Power's1 Plant Barry, equivalent to emissions from 25 megawatts of generating capacity. The CO 2 will be captured at the plant, transported via a short pipeline to Citronelle oilfield, and injected into brinesaturated Paluxy Formation sandstones at depths of approximately 9,400 to 10,500 ft. The Citronelle field is a working and actively maintained oilfield and provides the project team with a wealth of geophysical information as well as a pre-existing infrastructure to the project. However, completion practices employed in the field eliminates the use of a pre-existing well as the project’s primary injection well. This report outlines the major components of field operational activity and corresponding planning development for safe and reliable project performance: - Existing Infrastructure and Surface Facilities Construction; - Well Construction and Operations; - CO2 Injection; - Area of Review; - Monitoring, Verification and Accounting; - Project Closure.

01 COAL, LIGNITE, AND PEAT↗

CO 2 Sequestration Assessment of the basal sandstone in Tennessee (SECARB Phase III Work Product 1.6.a)

Geologic carbon sequestration is the permanent storage of CO 2 in deep underground geologic formations, which is preceded by the separation and capture of CO 2 at the point of emissions from a stationary source such as a coal-fired electric power plant. The United States Department of Energy’s (DOE’s) Office of Fossil Energy National Energy Technological Laboratory (NETL) is engaged in research and development of Carbon Sequestration Program technology. This report assesses potential geologic carbon dioxide (CO 2 ) storage capacity of the basal sandstone in Tennessee. The Southeast Regional Carbon Sequestration Partnership evaluated the Basal Sandstone in Tennessee for potential to store commercial quantities of CO 2 . This report expands upon the findings from the 2007 assessment of potential CO 2 storage reservoirs in the southeast United States, which included an initial assessment of the basal sandstone capacity. These estimates are based on limited and generalized data sets, which are primarily from published literature. In the 2007 report, the depth range for the basal sandstone was found to be 4,000 to 8,000 feet (ft) and the average thickness was 100 ft. The capacity estimate for the basal sandstone from the 2007 report was 2.5 gigatons (Gt) (metric) of CO 2 . Recognized the need for a more accurate estimate of capacity for the geologic sinks. This report provides a site specific, detailed geologic investigation of the basal sandstone. In this report the CO 2 storage capacity of the basal sandstone in Tennessee is assessed using an average reservoir total porosity, gross formation thickness, and average storage reservoir depth and pressure. The methodology is based on the capacity assessment methodology for saline aquifers in the United States Department of Energy 2010 Carbon Sequestration Atlas of the United States and Canada. Storage capacities are summarized in Table ES-1.

54 ENVIRONMENTAL SCIENCES↗

Methodology Paper for Lower and Upper Cretaceous Characterization (SECARB Phase III Work Product 1.4.a)

This document serves as the SECARB Phase III work product 1.4.a “Methodology Paper for Lower and Upper Cretaceous Characterization.” The product summarizes the Project Team’s plans for Phase III assessment of the Upper and Lower Cretaceous Saline Reservoirs CO 2 storage capacity. The Project Team will concentrate on potential geologic CO 2 storage reservoirs of the Lower and Upper Cretaceous formations in the Southeast Regional Carbon Sequestration Partnership (SECARB) along the eastern Gulf Coast region. This work will involve assembly of regional geologic cross sections to better define the stratigraphic framework for this high priority, regionally significant geological formation in the SECARB region. Best available well log data and all available core data will be incorporated into the regional analysis to assess reservoir properties and the geologic framework for storage reservoir characteristics. Regional structure maps and reservoir thickness maps will be compiled. Detailed structure maps will be created to assess the suitability of specific storage sites and to assess the potential impact of significant structural features on storage reservoir and confining unit integrity. Of importance will be incorporating the new information being developed from the Phase II and Phase III CO2 storage field projects that will be assessing this formation for storage of CO 2 . The primary deliverable will be input into the next update of the “Regional Atlas”.

54 ENVIRONMENTAL SCIENCES↗

Injection Well Construction Diagrams and Specifications (SECARB Work Product 5.2.1.b)

This report discusses the Anthropogenic Test’s Injection Wells (D-9-7#2 and D-9- 9#2) design and construction specifications. The report includes sections on: Drilling and casing program, Drilling fluids, Coring, Completion program, Logging and testing program, Drilling prognosis, Well closure and post-closure care plans. The injection wells have been designed to meet or exceed the Alabama Department of Environmental Management’s (ADEM) Class V Underground Injection Control (UIC) standards including those designed to protect underground sources of drinking water.

01 COAL, LIGNITE, AND PEAT↗

Initial Report on Reservoir Modeling (SECARB Phase III Work Product 4.2.4.b)

The SECARB Partnership Anthropogenic Test, located in the Southeast Unit of the Citronelle oilfield will inject CO 2 into the saline waters of the Cretaceous Paluxy sandstone formation for three to four years. In order to accurately model the injection, migration, and long-term fate of carbon dioxide (CO 2 ) in the subsurface, GEM-GHG, a Computer Modeling Group software program for reservoir simulation and transport modeling was selected for the simulation. GEM-GHG is a very robust compositional reservoir simulator, with all the necessary options available for modeling CO 2 trapping mechanisms (including solubility, residual gas and mineralization). This simulation tool is widely known and used in the petroleum and sequestration industries. A reservoir model was built, based on a previously developed comprehensive picture of the subsurface geology at the site (Work Product 4.2.1.d - Report on Subsurface Characterization for the Anthropogenic Test Project Site). This report describes in details the different inputs that were used to create the model as well as the results of the injection scenario in terms of achievable injection rates, plume extension and pressure response.

01 COAL, LIGNITE, AND PEAT↗

Report on Existing Infrastructure and Surface Project Suitability (SECARB Phase III Work Product 4.2.3.a)

This report discusses the suitability of the ground surface and existing surface infrastructure of the proposed Anthropogenic Test’s injection site surface to accommodate safe CO 2 off take from the supply pipeline, subsurface injection, and plume monitoring. Specifically, the report discusses: (1) The condition of the proposed location of injection and observation wells; (2) The test site terrain; (3) Delivery points for CO 2 and other services; (4) Surface and subsurface monitoring locations; and (5) CO 2 injection operations. Results of this study demonstrate that the injection test site has suitable surface conditions to accommodate the injection and monitoring operations. Previous reports on the test site’s subsurface geology (Work Product 4.2.1.d) and existing area wellbores (Work Product 4.2.1.c) similarly demonstrate the suitability of the Anthropogenic Test’s injection site for safe, long-term injection, storage, and monitoring operations.

01 COAL, LIGNITE, AND PEAT↗

Assessment of Anthropogenic Test Site Existing Subsurface Data (SECARB Phase III Work Product 4.2.1.b)

A test site and anthropogenic CO 2 source (the Anthropogenic Test) have been selected for a large-scale demonstration of carbon dioxide separation, capture and sequestration in southwestern Alabama as part of the Southeastern Regional Carbon Sequestration Partnership’s (SECARB) Phase III initiative. Plant Barry, a coal-fired power plant in southwestern Alabama, is the selected anthropogenic CO 2 source for the project and the designated storage test site is located in the southeast unit of the Citronelle oilfield. The target reservoir is the saline water-bearing sandstones in the Lower Cretaceous-age Paluxy formation.

01 COAL, LIGNITE, AND PEAT↗

Report on Subsurface Characterization of the Phase III Anthropogenic Test Project Site (SECARB Phase III Work Product 4.2.1.d)

A test site and anthropogenic carbon dioxide (CO 2 ) source have been selected for a large-scale demonstration of CO 2 separation, capture and sequestration in southwestern Alabama as part of the Southeastern Regional Carbon Sequestration Partnership’s (SECARB) Phase III initiative. The James M. Barry Generating Plant, a major coal-fired power plant in southwestern Alabama, is the selected anthropogenic CO 2 source for the project. The proposed storage test site is located in the Citronelle oil field, which lies at the crest of the Citronelle Dome. The proposed storage site is favorable for deep underground injection of CO 2 . Seismic activity in southwest Alabama is low and the absence of identified faulting in and near the Citronelle oil field indicates that the area provides a structurally stable environment for CO 2 storage operations. The porous and permeable sands of the proposed injection zone, the Paluxy Formation, present a favorable injection reservoir in terms of areal extent and petrophysical characteristics. The proposed confining zone, the Basal Shale of the overlying Washita-Fredericksburg Formation is persistent throughout the Citronelle area and appears to possess the appropriate criteria to act as an effective CO 2 seal. In addition to the Basal Washita-Fredericksburg Shale, secondary overlying confining units including the Middle (Marine) Tuscaloosa Formation, the Selma Group, and the Midway Shale, occur stratigraphically between the injection zone and the base of the lowermost underground source of drinking water (USDW). The Citronelle Dome is an ideal geometry for containment of CO 2 The dome is a subtle, anticlinal structure that contains a broad salt pillow at the core and provides fourway closure. At the test site, subsurface geologic strata, including the proposed injection and confining zones, dip to the east-south-east at about 1.25 degrees. Buoyant CO 2 is expected to migrate up dip towards the crest of the dome, where it will be contained within the structure of the dome. No faulting or significant fracture zones occur within the Dome. A vertical interval of over 8,000 feet with numerous low permeability barriers occurs between the proposed injection zone and the base of the lowermost USDW.

01 COAL, LIGNITE, AND PEAT↗

SECARB Design Specifications for Seismic Survey (SECARB Phase III Work Product 4.2.2.a)

A test site and anthropogenic CO 2 source have been selected for a large-scale demonstration of carbon dioxide separation, capture and sequestration in southwestern Alabama as part of the Southeastern Regional Carbon Sequestration Partnership’s (SECARB) Phase III initiative. The James M. Barry Generating Plant, a major coal-fired power plant in southwestern Alabama, is the selected anthropogenic CO 2 source for the project. The proposed storage test site is located in the Southeast Unit of the Citronelle oil field, which lies at the crest of the Citronelle Dome about 10 miles to the west of the power plant. The proposed storage site appears to be suitable for deep underground injection of CO 2 . An evaluation of the storage capacity and geological integrity of the proposed injection and confining intervals is a critical step in the assessment of the test site. This evaluation is important for several reasons, including project planning, permitting of injection wells, and the design and execution of injection and monitoring operations. Accordingly, the Geological Survey of Alabama (GSA) will conduct a detailed geological evaluation of the Southeast Citronelle Unit that emphasizes the acquisition, interpretation, and analysis of seismic reflection data. The goals of this work are to characterize the geologic structure of the area, verify that no faults are present, determine and analyze the seismic expression of sandstone and shale bodies in the Paluxy target interval, and to assist in the Underground Injection Control (UIC) permitting process.

01 COAL, LIGNITE, AND PEAT↗