Engineering PapersβŒ• Search

Engineering topics

Rice, E.

Publications and source records attributed to Rice, E..

Toward the Discovery of New Elements: Production of Livermorium (𝑍 = 116) with 50 Ti

The 244 Pu ⁒(50 Ti ,π‘₯⁒𝑛)⁒ 294βˆ’π‘₯ Lv reaction was investigated at Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron. The experiment was aimed at the production of a superheavy element with 𝑍 β‰₯114 by irradiating an actinide target with a beam heavier than 48 Ca. Produced Lv ions were separated from the unwanted beam and nuclear reaction products using the Berkeley Gas-filled Separator and implanted into a newly commissioned focal-plane detector system. Two decay chains were observed and assigned to the decay of 290 Lv . The production cross section was measured to be 𝜎 prod = 0.44($^{+0.58}_{βˆ’0.28}$) pb at a center-of-target center-of-mass energy of 220(3) MeV. Furthermore, this represents the first published measurement of the production of a superheavy element near the β€œisland of stability,” with a beam of 50 Ti and is an essential precursor in the pursuit of searching for new elements beyond 𝑍 =118.

36 MATERIALS SCIENCE↗

Estimate Low and High Order Wavefront Using P1640 Calibrator Measurements

P1640 high contrast imaging system on the Palomar 200 inch Telescope consists of an apodized-pupil Lyot coronagraph, the PALM-3000 adaptive optics (P3K-AO), and P1640 Calibrator (CAL). Science images are recorded by an integral field spectrograph covering J-H bands for detecting and characterizing stellar companions. With aberrations from atmosphere corrected by the P3K-AO, instrument performance is limited mainly by the quasi-static speckles due to noncommon path wavefront aberrations for the light to propagate to the P3K-AO wavefront sensor and to the coronagraph mask. The non-common path wavefront aberrations are sensed by CAL, which measures the post-coronagraph E-field using interferometry, and can be effectively corrected by offsetting the P3K-AO deformable mirror target position accordingly. Previously, we have demonstrated using CAL measurements to correct high order wavefront aberrations, which is directly connected to the static speckles in the image plane. Low order wavefront, on the other hand, usually of larger amplitudes, causes light to leak through the coronagraph making the whole image plane brighter. Knowledge error in low order wavefront aberrations can also affect the estimation of the high order wavefront. Even though, CAL is designed to sense efficiently high order wavefront aberrations, the low order wavefront front can be inferred with less sensitivity. Here, we describe our method for estimating both low and high order wavefront aberrations using CAL measurements by propagating the post-coronagraph E-field to a pupil before the coronagraph. We present the results from applying this method to both simulated and experiment data.

aberrations↗

A First Order Wavefront Estimation Algorithm for P1640 Calibrator

P1640 calibrator is a wavefront sensor working with the P1640 coronagraph and the Palomar 3000 actuator adaptive optics system (P3K) at the Palomar 200 inch Hale telescope. It measures the wavefront by interfering post-coronagraph light with a reference beam formed by low-pass filtering the blocked light from the coronagraph focal plane mask. The P1640 instrument has a similar architecture to the Gemini Planet Imager (GPI) and its performance is currently limited by the quasi-static speckles due to non-common path wavefront errors, which comes from the non-common path for the light to arrive at the AO wavefront sensor and the coronagraph mask. By measuring the wavefront after the coronagraph mask, the non-common path wavefront error can be estimated and corrected by feeding back the error signal to the deformable mirror (DM) of the P3K AO system. Here, we present a first order wavefront estimation algorithm and an instrument calibration scheme used in experiments done recently at Palomar observatory. We calibrate the P1640 calibrator by measuring its responses to poking DM actuators with a sparse checkerboard pattern at different amplitudes. The calibration yields a complex normalization factor for wavefront estimation and establishes the registration of the DM actuators at the pupil camera of the P1640 calibrator, necessary for wavefront correction. Improvement of imaging quality after feeding back the wavefront correction to the AO system demonstrated the efficacy of the algorithm.

Wavefront sensing↗

Effect of shear on duct wall impedance.

The solution to the equation governing the propagation of sound in a uniform shear layer is expressed in terms of parabolic cylinder functions. This result is used to develop a closed-form solution for acoustic wall impedance which accounts for both the duct liner and the presence of a boundary layer in the duct. The effective wall impedance can then be used as the boundary condition for the much simpler problem of sound propagation in uniform flow.

Goldstein, M.β†—