Engineering PapersSearch

Engineering topics

Ribet, Stephanie M

Publications and source records attributed to Ribet, Stephanie M.

Multi-angle Precession Electron Diffraction (MAPED): A Versatile Approach to 4D-STEM Precession

Precession of a converged beam during acquisition of a 4D-STEM dataset improves strain, orientation, and phase mapping accuracy by averaging over continuous angles of illumination. Precession experiments usually rely on integrated systems, where automatic alignments lead to fast, high-quality results. The dependence of these experiments on specific hardware and software is evident even when switching to nonintegrated detectors on a precession tool, as experimental set-up becomes challenging and time-consuming. Here, we introduce multi-angle precession electron diffraction (MAPED): a method to perform electron diffraction by collecting sequential 4D-STEM scans at different incident beam tilts. The multiple diffraction datasets are averaged together postacquisition, resulting in a single dataset that minimizes the impact of the curvature and orientation of the Ewald sphere relative to the crystal under study. Our results demonstrate that even four additional tilts improved measurement of material properties, namely strain and orientation, as compared to single-tilt 4D-STEM experiments. We show the versatility and flexibility of our MAPED approach with data collected on a number of microscopes with different hardware configurations and a variety of detectors.

4D-STEM

Neutral but Impactful: Gallium Cluster-Induced Nanopores from Beam-Blanked Gallium Ion Sources

Neutral atoms originating from liquid metal ion sources are an often-overlooked source of contamination and damage in focused ion beam microscopy. Beyond ions and single atoms, these sources also generate atom clusters. While most studies have investigated charged clusters, here we demonstrate that neutral clusters are also formed. These neutral clusters bypass the electrostatic beam blanking system, allowing them to impinge on samples even when the ion beam is blanked. We investigate this phenomenon using thin (≤20 nm) freestanding membranes of hexagonal boron nitride, silicon, and silicon nitride as targets. Randomly dispersed nanopores that form upon neutral cluster exposure are revealed. The average nanopore diameter is ∼2 nm with a narrow size distribution, suggesting that the atom clusters have a preferred size. Various electron microscopy techniques are used to characterize the nanopores, including high-resolution transmission electron microscopy, multislice ptychography, and electron energy-loss spectroscopy. Finally, we show how electron irradiation in the transmission electron microscope can be used to both remove any amorphous material that may clog the pores and to controllably grow the pores to specific sizes. Tunable nanopores such as these are interesting for nanofluidic applications requiring size-selective membranes.

Byrne, Dana O

PhaseT3M: 3D imaging at 1.6 Å resolution via electron cryo-tomography with nonlinear phase retrieval

Electron cryo-tomography (cryo-ET) enables 3D imaging of complex, radiation-sensitive structures with molecular detail. However, image contrast from the interference of scattered electrons is nonlinear with atomic density and multiple scattering further complicates interpretation. These effects degrade resolution, particularly in conventional reconstruction algorithms, which assume linearity. Particle averaging can reduce such issues but is unsuitable for heterogeneous or dynamic samples ubiquitous in biology, chemistry, and materials sciences. Here, we develop a phase retrieval-based cryo-ET method, PhaseT3M. We experimentally demonstrate its application to an approximately 7 nm Co3O4 nanoparticle on an approximately 30 nm carbon substrate, achieving a maximum resolution of 1.6 Å, surpassing conventional limits using standard cryo-TEM equipment. PhaseT3M uses a multislice model for multiple scattering and Bayesian optimization for alignment and computational aberration correction, with a positivity constraint to recover ‘missing wedge’ information. Applied directly to biological particles, it enhances reconstruction quality and reduces artifacts, establishing a standard for routine 3D imaging with phase contrast.

Biophysics

BEACON—automated aberration correction for scanning transmission electron microscopy using Bayesian optimization

Aberration correction is an important aspect of modern high-resolution scanning transmission electron microscopy. Most methods of aligning aberration correctors require specialized sample regions and are unsuitable for fine-tuning aberrations without interrupting on-going experiments. Here, we present an automated method of correcting first- and second-order aberrations called BEACON, which uses Bayesian optimization of the normalized image variance to efficiently determine the optimal corrector settings. We demonstrate its use on gold nanoparticles and a hafnium dioxide thin film showing its versatility in nano- and atomic-scale experiments. BEACON can correct all first- and second-order aberrations simultaneously to achieve an initial alignment and first- and second-order aberrations independently for fine alignment. Ptychographic reconstructions are used to demonstrate an improvement in probe shape and a reduction in the target aberration.

techniques and instrumentation