Reininger, R

Publications and source records attributed to Reininger, R.

Optimization of the Coherent Intensity from Multi-Segment Undulators by Phase Matching

The use of inline insertion devices at third-generation synchrotron radiation sources can result in destructive interference effects if the relative phase between the devices is not properly adjusted. The destructive interference can strongly affect the emission spectrum and coherent wavefront of a compound insertion device. We simulate the photon source generated by a dual-inline elliptically polarizing undulator (EPU) situated in a low-{beta} straight section of the planned NSLS-II storage ring and show that a magnetic chicane with adjustable field integral can be used to phase-match the devices. Furthermore, we show that the maximum coherent intensity is delivered by a focusing x-ray beamline if the chicane is adjusted to phase-match the off-axis and red-shifted radiation. Such a system will be installed at the coherent soft x-ray (CSX) beamline of the NSLS-II in order to provide the highest possible coherent flux for coherent soft x-ray scattering experiments.

36 MATERIALS SCIENCE↗

The electron spectro-microscopy beamline at National Synchrotron Light Source II: A wide photon energy range, micro-focusing beamline for photoelectron spectro-microscopies

A comprehensive optical design for a high-resolution, high-flux, wide-energy range, micro-focused beamline working in the vacuum ultraviolet and soft x-ray photon energy range is proposed. The beamline is to provide monochromatic radiation to three photoelectron microscopes: a full-field x-ray photoelectron emission microscope and two scanning instruments, one dedicated to angle resolved photoemission spectroscopy ({mu}-ARPES) and one for ambient pressure x-ray photoelectron spectroscopy and scanning photoelectron microscopy (AP-XPS/SPEM). Microfocusing is achieved with state of the art elliptical cylinders, obtaining a spot size of 1 {mu}m for ARPES and 0.5 {mu}m for AP-XPS/SPEM. A detailed ray tracing analysis quantitatively evaluates the overall beamline performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New SRC APPLE ll Variable Polarization Beamline

SRC has recently commissioned a new Varied Line-Spacing Plane Grating Monochromator (VLS-PGM) utilizing as its source a 1 m long APPLE II insertion device in short-straight-section 9 of the Aladdin storage ring. The insertion device reliably delivers horizontal, vertical, and right and left circularly polarized light to the beamline. Measurements from an in situ polarimeter can be used for undulator corrections to compensate for depolarizing effects of the beamline. The beamline has only three optical elements and covers the energy range from 11.1 to 270 eV using two varied line-spacing gratings. A plane mirror rotates to illuminate the gratings at the correct angle to cancel the defocus term at all photon energies. An exit slit and elliptical-toroid refocusing mirror complete the beamline. Using a 50 {mu}m exit slit, the beamline provides moderate to high resolution, with measured flux in the mid 10{sup 12} (photons/s/200 mA) range, and a spot size of 400 {mu}m horizontal by 30 {mu}m vertical.

43 PARTICLE ACCELERATORS↗

Optimization of the Coherent Intensity from Multi-Segment Undulators by Phase Matching

The use of inline insertion devices at third-generation synchrotron radiation sources can result in destructive interference effects if the relative phase between the devices is not properly adjusted. The destructive interference can strongly affect the emission spectrum and coherent wavefront of a compound insertion device. We simulate the photon source generated by a dual-inline elliptically polarizing undulator (EPU) situated in a low-{beta} straight section of the planned NSLS-II storage ring and show that a magnetic chicane with adjustable field integral can be used to phase-match the devices. Furthermore, we show that the maximum coherent intensity is delivered by a focusing x-ray beamline if the chicane is adjusted to phase-match the off-axis and red-shifted radiation. Such a system will be installed at the coherent soft x-ray (CSX) beamline of the NSLS-II in order to provide the highest possible coherent flux for coherent soft x-ray scattering experiments.

07 ISOTOPE AND RADIATION SOURCES↗

Optimization of a coherent soft x-ray beamline for coherent scattering experiments at NSLS-II

The coherent soft x-ray and full polarization control (CSX) beamline at the National Synchrotron Light Source - II (NSLS-II) will deliver 1013 coherent photons per second in the energy range of 0.2-2 keV with a resolving power of 2000. The source, a dual elliptically polarizing undulator (EPU), and beamline optics should be optimized to deliver the highest possible coherent flux in a 10-30 {micro}m spot for use in coherent scattering experiments. Using the computer code Synchrotron Radiation Workshop (SRW), we simulate the photon source and focusing optics in order to investigate the conditions which provide the highest usable coherent intensity on the sample. In particular, we find that an intermediate phasing magnet is needed to correct for the relative phase between the two EPUs and that the optimum phase setting produces a spectrum in which the desired wavelength is slightly red-shifted thus requiring a larger aperture than originally anticipated. This setting is distinct from that which produces an on-axis spectrum similar to a single long undulator. Furthermore, partial coherence calculations, utilizing a multiple electron approach, indicate that a high degree of spatial coherence is still obtained at the sample location when such an aperture is used. The aperture size which maximizes the signal-to-noise ratio of a double-slit experiment is explored. This combination of high coherence and intensity is ideally suited for x-ray ptychography experiments which reconstruct the scattering density from micro-diffraction patterns. This technique is briefly reviewed and the effects on the image quality of proximity to the beamline focus are explored.

36 MATERIALS SCIENCE↗

The Nanoscience Beamline (I06) at Diamond Light Source

The Nanoscience beamline (I06) is one of seven Diamond Phase-I beamlines which has been operational since January 2007 delivering polarised soft x-rays, for a PhotoEmission Electron Microscope (PEEM) and branchline, in the energy range 80-2100 eV. The beamline is based on a collimated plane grating monochromator with sagittal focusing elements, utilising two APPLE II helical undulator sources, and has been designed for high flux density at the PEEM sample position. A {approx}5 {mu}m ({sigma}) diameter beam is focussed onto the sample in the PEEM allowing a range of experiments using x-ray absorption spectroscopy (XAS), x-ray magnetic circular dichroism (XMCD) and x-ray magnetic linear dichroism (XMLD) as contrast mechanisms. The beamline is also equipped with a branchline housing a 6T superconducting magnet for XMCD and XMLD experiments. The magnet is designed to move on and off the branchline which allows a diverse range of experiments.

43 PARTICLE ACCELERATORS↗

Preliminary Commissioning and Performance of the Soft X-ray Micro-characterization Beamline at the Canadian Light Source

The Soft X-ray Micro-characterization Beamline (SXRMB) is a medium energy, bending magnet based beamline, designed to cover an energy range of 1.7-10 keV using two sets of crystals--InSb(111) and Si(111). The design goal is to deliver a flux of 2x10{sup 11} photons sec{sup -1}/100 mA with a resolution up to 10,000 for X-ray Absorption Spectroscopy. A KB mirror stage is designed to provide microprobe capability, with a spot size of 10x10 {mu}m{sup 2} and a flux of >10{sup 9} at the microprobe station. The beamline has been in the commissioning phase since 2008, and access to the X-ray absorption endstation is now open to general users. The optical commissioning and performance of the beamline is presented with some early experimental results.

43 PARTICLE ACCELERATORS↗

A Beamline for Fast Polarization Switching at NSLS-II

The first XUV beamline (200-2000 eV) at NSLS-II will have two branches, one optimized for photon hungry experiments requiring high coherent flux and one optimized for studies of polarization sensitive materials and interfaces based on fast polarization switching. We describe here the branch designed for fast polarization switching with frequencies up to 1 kHz, high photon flux, and good energy resolution. The beamline will be served by two canted undulators and is based on the focusing variable line spacing grating monochromator. The two beams will be focused at the same spot of approximately 80x10 {mu}m (hor.xver.). The expected circular polarized flux at the sample from each device up to 1.4 keV will be higher than 10{sup 12} photons/s at a resolving power better than 10{sup 4}. An additional KB focusing system will deliver the two beams to a spot in the {mu}m range.

43 PARTICLE ACCELERATORS↗