Engineering Papers⌕ Search

Engineering topics

Reinath, Michael S.

Publications and source records attributed to Reinath, Michael S..

Doppler Global Velocimeter Development for the Large Wind Tunnels at Ames Research Center

Development of an optical, laser-based flow-field measurement technique for large wind tunnels is described. The technique uses laser sheet illumination and charged coupled device detectors to rapidly measure flow-field velocity distributions over large planar regions of the flow. Sample measurements are presented that illustrate the capability of the technique. An analysis of measurement uncertainty, which focuses on the random component of uncertainty, shows that precision uncertainty is not dependent on the measured velocity magnitude. For a single-image measurement, the analysis predicts a precision uncertainty of +/-5 m/s. When multiple images are averaged, this uncertainty is shown to decrease. For an average of 100 images, for example, the analysis shows that a precision uncertainty of +/-0.5 m/s can be expected. Sample applications show that vectors aligned with an orthogonal coordinate system are difficult to measure directly. An algebraic transformation is presented which converts measured vectors to the desired orthogonal components. Uncertainty propagation is then used to show how the uncertainty propagates from the direct measurements to the orthogonal components. For a typical forward-scatter viewing geometry, the propagation analysis predicts precision uncertainties of +/-4, +/-7, and +/-6 m/s, respectively, for the U, V, and W components at 68% confidence.

Reinath, Michael S.↗

Laser Velocimeter For Outdoor Or Wind-Tunnel Measurements

Laser velocimeter developed for remotely controlled operation in large wind tunnel or at outdoor aircraft-testing site. Long-range laser velocimeter has expanded focal range and ability to measure two perpendicular components of velocity simultaneously. Includes electronic subsystems for control and acquisition of data.

Reinath, Michael S.↗

A long-range laser velocimeter

A long-range laser velocimeter (LV) developed for remote operation from within the flow fields of large wind tunnels is described. Emphasis is placed on recent improvements in optical hardware as well as recent additions to data acquisition and processing techniques. The method used for data reduction of photon resolved signals is outlined in detail, and measurement accuracy is discussed. To study the performance of the LV and verify the measurement accuracy, laboratory measurements were made in the flow field of a 10-cm-diameter, 30-m/s axisymetric jet. The measured velocity and turbulence intensity surveys are compared with measurements made with a hot-wire anemometer. Additionally, the LV was used during the flow calibration of the 80-ft x 120-ft wind tunnel to measure the test-section boundary-layer thickness at the maximum wind tunnel speed of 51.5 m/s. The requirements and techniques used to seed the flow are discussed, and boundary-layer surveys of mean velocity and turbulence intensity of the streamwise component and the component normal to the surface are presented. The streamwise component of mean velocity is compared with data obtained with a total pressure rake.

Reinath, Michael S.↗

Laser Velocimetry In Low-Speed Wind Tunnels

Design and performance of three-dimensional and two-dimensional backscatter laser velocimeter, both used in low-speed wind tunnels, described in report together with historical overview of development of laser velocimetry (LV). Provides measurements of airflow in wind-tunnel tests without perturbing effects of probes and probe-supporting structures. Applicable in such related fields as ventilation engineering and possibly in detection of wing vortexes from large aircraft at airports.

Orloff, Kenneth L.↗

A long-range laser velocimeter for the National Full-Scale Aerodynamics Complex: New developments and experimental application

A long-range laser velocimeter (LV) developed for remote operation from within the flow fields of the large wind tunnels of the National Full-Scale Aerodynamics Complex is described. Emphasis is placed on recent improvements in optical hardware as well as recent additions to data acquisition and processing techniques. The system has been upgraded from a dual-beam, single-color LV with focal range to 10 m, to a dual-beam, two-color LV with focal range to 20 m. At the new extended measurement range (between 10 and 20 m), signals are photon-resolved, and a photon correlation technique is applied to acquire and process the LV signals. This technique permits recovery of the velocity probability distributions at a particular measurement location from which the mean components of velocity and the corresponding normal stress components of turbulence are obtained. The method used for data reduction is outlined in detail, and a discussion of measurement accuracy is made. To study the performance of the LV and verify the measurement accuracy, laboratory measurements were made in the flow field of a 10 cm-diameter, 30-m/sec axisymmetric jet. A discussion of the requirements and techniques used to seed the flow is made, and boundary-layer surveys of mean velocity and turbulence intensity of the streamwise component and the component normal to the surface are presented.

Reinath, Michael S.↗