Design and performance of a high-pressure-ratio, highly loaded axial-flow transonic compressor space

A 50-cm-diam. axial-flow transonic compressor stage with multiple-circular-arc blades was designed and tested. At design speed, a rotor peak efficiency of 0.85 occurred at an equivalent weight flow of 29.3 kg/sec. Stage peak efficiency was 0.79 at 28.6 kg/sec. Stage total pressure ratio at peak efficiency was 1.84. The stall margin at design speed was 5 percent. Rotor and stator losses were higher than predicted. The stator choked at design flow.

Lewis, G. W., Jr.

Performance of a transonic compressor rotor with an aspect ratio of 6.5

The overall and blade-element performances and the aerodynamic design parameters of a transonic rotor with an aspect ratio of 6.5, designed to investigate the effects of aspect ratio on range and performance are presented. The rotor was designed for a total-pressure ratio of 1.53, an efficiency of 0.898, and a weight flow of 67.76 pounds per second.

Reid, L.

Overall and blade-element performance of a multiple-circular-arc bladed transonic compressor rotor with tip speed of 1375 feet per second

The design and experimental performance of a 20-inch-diameter multiple-circular-arc bladed axial-flow transonic compressor rotor is presented. Radial surveys of the flow conditions were made. At design speed the peak efficiency was 0.882 and occurred at a weight flow of 64.0 pounds per second. At this point the total-pressure and total-temperature ratios were 1.79 and 1.205, respectively. The stall margin at design speed was 8 percent based on weight flows and total-pressure ratios at experimental peak efficiency and near stall. The measured stall margin was 20 percent at design weight flow and speed.

Kovich, G.

Overall and blade-element performance of a transonic compressor stage with multiple-circular-arc blades at tip speed of 419 meters per second

A 50-centimeter-diameter axial-flow transonic compressor stage with multiple-circular-arc blades was designed and tested to study the effects of blade shape on efficiency and stall margin. At design speed, peak efficiency of 0.80 occurred at an equivalent weight flow of 29.0 kilograms per second. Measured total pressure ratio and total temperature ratio at peak efficiency were 1.69 and 1.20, respectively. The stall margin at design speed and an equivalent weight flow of 29.0 kilograms per second was 9 percent. The measured stall margin at design weight flow and speed was 15 percent. A comparison of rotor performance made with and without the stator showed a decrease in pressure ratio, peak efficiency, and maximum weight flow with the addition of the stator.

Kovich, G.

Performance of a single-stage axial-flow transonic compressor stage with a blade tip solidity of 1.7

The overall and blade-element performance of a transonic compressor stage is presented over the stable operating range at rotative speeds from 50 to 100 percent of design speed. Stage peak efficiency of 0.784 was obtained at a weight flow of 28.6 kilograms per second and a pressure ratio of 1.706. Stall margin at design speed was 11.4 percent. The peak efficiency being significantly less than design efficiency was attributed to: (1) the stator loss and the radial gradient of losses being much higher than design, (2) the losses and blockages associated with the rotor part-span dampers not being incorporated into the design, and (3) mismatch of the rotor and stator badle elements.

Moore, R. D.

Effects of increased leading-edge thickness on performance of a transonic rotor blade

A single-stage transonic compressor was tested with two rotor blade leading-edge configurations to investigate the effect of increased leading-edge thickness on the performance of a transonic blade row. The original rotor blade configuration was modified by cutting back the leading edge sufficiently to double the blade leading-edge thickness and thus the blade gap blockage in the tip region. At design speed this modification resulted in a decrease in rotor overall peak efficiency of four points. The major portion of this decrement in rotor overall peak efficienty was attributed to the flow conditions in the outer 30 percent of the blade span. At 70 and 90 percent of design speed, the modification had very little effect on rotor overall performance.

Reid, L.

Performance of a 1380-foot-per-second-tip-speed axial-flow compressor rotor with a blade tip solidity of 1.3

Aerodynamic design parameters are presented along the overall and blade element performance, of an axial flow compressor rotor designed to study the effects of blade solidity on efficiency and stall margin. At design speed the peak efficiency was 0.844 and occurred at an equivalent weight flow of 63.5 lb/sec with a total pressure ratio of 1.801. Design efficiency, pressure ratio, and weight flow 0.814, 1.65, and 65.3(41.1 lb/sec/sq ft of annulus area), respectively. Stall margin for design speed was 6.4 percent based on the weight flow and pressure ratio values at peak efficiency and just prior to stall.

Hager, R. D.

Performance of 1380 foot per second tip-speed axial-flow compressor rotor blade tip solidity of 1.5

This presents the aerodynamic design parameters along with the overall and blade element performance of an axial-flow compressor rotor designed to study the effects of blade solidity on efficiency and stall margin. At design speed the peak efficiency was 0.892 and occurred at an equivalent weight flow of 65.0 lb/sec. The total pressure ratio was 1.83 and the total temperature ratio was 1.215. Design efficiency, weight flow, pressure ratio, and temperature ratio were 0.824, 65.3, 1.65, and 1.187, respectively. Stall margin for design speed was 10 percent based on the weight flow and pressure ratio values at peak efficiency and just prior to stall.

Ball, C. L.