Assessing States# Industrial Capabilities in Support of Safeguards State Evaluation and Implementation Activities (INMM Paper)
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Reed, J.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided
Abstract not provided
Purpose: Brachytherapy sources with variable longitudinal strength (VLS) allow for a customized intensity along the length of the source. These have applications in focal brachytherapy treatments of prostate cancer where dose boosting can be achieved through modulation of intra-source strengths. This work focused on development of a calibration methodology for VLS sources based on measurements and Monte Carlo (MC) simulations of five 1 cm {sup 10} {sup 3}Pd sources each containing four regions of variable {sup 103}Pd strength. Methods: The air-kerma strengths of the sources were measured with a variable-aperture free-air chamber (VAFAC). Source strengths were also measured using a well chamber. The in-air azimuthal and polar anisotropy of the sources were measured by rotating them in front of a NaI scintillation detector and were calculated with MC simulations. Azimuthal anisotropy results were normalized to their mean intensity values. Polar anisotropy results were normalized to their average transverse axis intensity values. The relative longitudinal strengths of the sources were measured via on-contact irradiations with radiochromic film, and were calculated with MC simulations. Results: The variable {sup 103}Pd loading of the sources was validated by VAFAC and well chamber measurements. Ratios of VAFAC air-kerma strengths and well chamber responses were within ±1.3% for all sources. Azimuthal anisotropy results indicated that ≥95% of the normalized values for all sources were within ±1.7% of the mean values. Polar anisotropy results indicated variations within ±0.3% for a ±7.6° angular region with respect to the source transverse axis. Locations and intensities of the {sup 103}Pd regions were validated by radiochromic film measurements and MC simulations. Conclusion: The calibration methodology developed in this work confirms that the VLS sources investigated have a high level of polar uniformity, and that the strength and longitudinal intensity can be verified experimentally and through MC simulations. {sup 103}Pd sources were provided by CivaTech Oncology, Inc.
Purpose: The CivaSheet™ is a new directional Pd-103 planar source array, with a variable number of discrete source elements referred to as “dots”. Each dot consists of a polymer capsule containing {sup 103}Pd and a gold shield that attenuates radiation on one side of the device to define hot and cold dose regions. Fluorescence from the gold shield is observed in the dot spectrum. Since CivaSheet™ is a planar directional source, conventional methods used for calibration of azimuthally symmetric sources are not applicable. The purpose of this work is to establish an air-kerma-strength standard and a transfer to a well chamber for clinical calibration. Methods: Primary air-kerma strength measurement of the dots was performed using a variable-aperture free-air chamber (VAFAC). Charge measurements were recorded using a well chamber with a custom insert. Anisotropy measurements were performed using a Sodium-Iodide detector. Spectral measurements were performed using a low-energy germanium detector and compared to a source without gold. The dot geometry was modeled using the MCNP6 radiation transport code. Results: Air-kerma strength measurements of a batch of four dots performed with the VAFAC were within ±1.5% of the average measured value and the measurement precision was within ±0.5%. Anisotropy measurements indicated uniform emission within the measurement uncertainty for the solid angle defining the VAFAC aperture used. Charge measurements of each dot using the well chamber in four cardinal angle source orientations were within ±1.5% of the average measured values. The spectral study of a dot resulted in identification of fluorescence from the gold shield and primary spectral energies that were compared to MCNP6 simulations. Conclusion: Calibration procedures for the new directional Pd-103 source dot were established for future clinical use, based on the results of experimental and Monte Carlo investigations. This work was partially supported by NCI contract (HHSN261201200052C) through CivaTech Oncology Inc.
Purpose: To determine the in-air azimuthal anisotropy and in-water dose distribution for the 1 cm length of the CivaString {sup 103}Pd brachytherapy source through measurements and Monte Carlo (MC) simulations. American Association of Physicists in Medicine Task Group No. 43 (TG-43) dosimetry parameters were also determined for this source. Methods: The in-air azimuthal anisotropy of the source was measured with a NaI scintillation detector and simulated with the MCNP5 radiation transport code. Measured and simulated results were normalized to their respective mean values and compared. The TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function for this source were determined from LiF:Mg,Ti thermoluminescent dosimeter (TLD) measurements and MC simulations. The impact of {sup 103}Pd well-loading variability on the in-water dose distribution was investigated using MC simulations by comparing the dose distribution for a source model with four wells of equal strength to that for a source model with strengths increased by 1% for two of the four wells. Results: NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy showed that ≥95% of the normalized data were within 1.2% of the mean value. TLD measurements and MC simulations of the TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function agreed to within the experimental TLD uncertainties (k=2). MC simulations showed that a 1% variability in {sup 103}Pd well-loading resulted in changes of <0.1%, <0.1%, and <0.3% in the TG-43 dose-rate constant, radial dose distribution, and polar dose distribution, respectively. Conclusion: The CivaString source has a high degree of azimuthal symmetry as indicated by the NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy. TG-43 dosimetry parameters for this source were determined from TLD measurements and MC simulations. {sup 103}Pd well-loading variability results in minimal variations in the in-water dose distribution according to MC simulations. This work was partially supported by CivaTech Oncology, Inc. through an educational grant for Joshua Reed, John Micka, Wesley Culberson, and Larry DeWerd and through research support for Mark Rivard.
With many safeguards experts in the United States at or near retirement age, and with the growing and evolving mission of international safeguards, attracting and educating a new generation of safeguards experts is an important element of maintaining a credible and capable international safeguards system. The United States National Laboratories, with their rich experience in addressing the technical and policy challenges of international safeguards, are an important resource for attracting, educating, and training future safeguards experts. This presentation highlights some of the safeguards education and professional development activities underway at the National Laboratories. These include university outreach, summer courses, internships, mid-career transition, knowledge retention, and other projects. The presentation concludes with thoughts on the challenge of interdisciplinary education and the recruitment of individuals with the right balance of skills and backgrounds are recruited to meet tomorrow's needs.
We have measured the inclusive semileptonic branching fractions of D{sup 0}, D{sup +}, and D{sub s}{sup +} mesons. For these measurements, we have used the full CLEO-c open-charm data samples, 818 pb{sup -1} at E{sub CM}=3.774 GeV, giving D{sup 0}D{sup 0} and D{sup +}D{sup -} events, and 602 pb{sup -1} at E{sub CM}=4.170 GeV, giving D{sub s}*{sup {+-}D}{sub s}{sup {+-}}events. We obtain B(D{sup 0{yields}}Xe{sup +{nu}}{sub e})=(6.46{+-}0.09{+-}0.11)%, B(D{sup +{yields}}Xe{sup +{nu}}{sub e})=(16.13{+-}0.10{+-}0.29)%, and B(D{sub s}{sup +{yields}}Xe{sup +{nu}}{sub e})=(6.52{+-}0.39{+-}0.15)%, where the first uncertainties are statistical and the second are systematic. From these and lifetimes obtained elsewhere, we obtain the ratios of semileptonic decay widths {Gamma}(D{sup +{yields}}Xe{sup +{nu}}{sub e})/{Gamma}(D{sup 0{yields}}Xe{sup +{nu}}{sub e})=0.985{+-}0.015{+-}0.024 and {Gamma}(D{sub s}{sup +{yields}}Xe{sup +{nu}}{sub e})/{Gamma}(D{sup 0{yields}}Xe{sup +{nu}}{sub e})=0.828{+-}0.051{+-}0.025. The ratio of D{sup +} and D{sup 0} is consistent with the isospin symmetry prediction of unity, and the ratio of D{sub s}{sup +} and D{sup 0} differs from unity, as expected.
We report evidence for the ground state of bottomonium, {eta}{sub b}(1S), in the radiative decay {Upsilon}(3S){yields}{gamma}{eta}{sub b} in e{sup +}e{sup -} annihilation data taken with the CLEO III detector. Using 6x10{sup 6} {Upsilon}(3S) decays, and assuming {Gamma}({eta}{sub b})=10{+-}5 MeV/c{sup 2}, we obtain B({Upsilon}(3S){yields}{gamma}{eta}{sub b})=(7.1{+-}1.8{+-}1.3)x10{sup -4}, where the first error is statistical and the second is systematic. The statistical significance is {approx}4{sigma}. The mass is determined to be M({eta}{sub b})=9391.8{+-}6.6{+-}2.0 MeV/c{sup 2}, which corresponds to the hyperfine splitting {Delta}M{sub hf}(1S){sub b}=68.5{+-}6.6{+-}2.0 MeV/c{sup 2}. Using 9x10{sup 6} {Upsilon}(2S) decays, we place an upper limit on the corresponding {Upsilon}(2S) decay, B({Upsilon}(2S){yields}{gamma}{eta}{sub b})<8.4x10{sup -4} at 90% confidence level.
Using 24x10{sup 6} {psi}{sup '}{identical_to}{psi}(2S) decays in CLEO-c, we have searched for higher multipole admixtures in electric-dipole-dominated radiative transitions in charmonia. We find good agreement between our data and theoretical predictions for magnetic quadrupole (M2) amplitudes in the transitions {psi}{sup '}{yields}{gamma}{chi}{sub c1,c2} and {chi}{sub c1,c2}{yields}{gamma}J/{psi}, in striking contrast to some previous measurements. Let b{sub 2}{sup J} and a{sub 2}{sup J} denote the normalized M2 amplitudes in the respective aforementioned decays, where the superscript J refers to the angular momentum of the {chi}{sub cJ}. By performing unbinned maximum likelihood fits to full five-parameter angular distributions, we found the following values of M2 admixtures for J{sub {chi}}=1: a{sub 2}{sup J={sup 1}}=(-6.26{+-}0.63{+-}0.24)x10{sup -2} and b{sub 2}{sup J={sup 1}}=(2.76{+-}0.73{+-}0.23)x10{sup -2}, which agree well with theoretical expectations for a vanishing anomalous magnetic moment of the charm quark. For J{sub {chi}}=2, if we fix the electric octupole (E3) amplitudes to zero as theory predicts for transitions between charmonium S states and P states, we find a{sub 2}{sup J={sup 2}}=(-9.3{+-}1.6{+-}0.3)x10{sup -2} and b{sub 2}{sup J={sup 2}}=(1.0{+-}1.3{+-}0.3)x10{sup -2}. If we allow for E3 amplitudes we find, with a four-parameter fit, a{sub 2}{sup J={sup 2}}=(-7.9{+-}1.9{+-}0.3)x10{sup -2}, b{sub 2}{sup J={sup 2}}=(0.2{+-}1.4{+-}0.4)x10{sup -2}, a{sub 3}{sup J={sup 2}}=(1.7{+-}1.4{+-}0.3)x10{sup -2}, and b{sub 3}{sup J={sup 2}}=(-0.8{+-}1.2{+-}0.2)x10{sup -2}. We determine the ratios a{sub 2}{sup J={sup 1}}/a{sub 2}{sup J={sup 2}}=0.67{sub -0.13}{sup +0.19} and a{sub 2}{sup J={sup 1}}/b{sub 2}{sup J={sup 1}}=-2.27{sub -0.99}{sup +0.57}, where the theoretical predictions are independent of the charmed quark magnetic moment and are a{sub 2}{sup J={sup 1}}/a{sub 2}{sup J={sup 2}}=0.676{+-}0.071 and a{sub 2}{sup J={sup 1}}/b{sub 2}{sup J={sup 1}}=-2.27{+-}0.16.
Analyzing 600 pb{sup -1} of e{sup +}e{sup -} collisions at 4170 MeV center-of-mass energy with the CLEO-c detector, we measure the branching fraction B(D{sub s}{sup +}{yields}{tau}{sup +}{nu})=(5.52{+-}0.57{+-}0.21)% using the {tau}{sup +}{yields}{rho}{sup +}{nu} decay mode. Combining with other CLEO measurements of B(D{sub s}{sup +}{yields}{tau}{sup +}{nu}) we determine the pseudoscalar decay constant f{sub D{sub s}}=(259.7{+-}7.8{+-}3.4) MeV consistent with the value obtained from our D{sub s}{sup +}{yields}{mu}{sup +}{nu} measurement of (257.6{+-}10.3{+-}4.3) MeV. Combining these measurements we find a value of f{sub D{sub s}}=(259.0{+-}6.2{+-}3.0) MeV, that differs from the most accurate prediction based on unquenched lattice gauge theory of (241{+-}3) MeV by 2.4 standard deviations. We also present the first measurements of B(D{sub s}{sup +}{yields}K{sup 0}{pi}{sup +}{pi}{sup 0})=(1.00{+-}0.18{+-}0.04)%, and B(D{sub s}{sup +}{yields}{pi}{sup +}{pi}{sup 0}{pi}{sup 0})=(0.65{+-}0.13{+-}0.03)%, and measure a new value for B(D{sub s}{sup +}{yields}{eta}{rho}{sup +})=(8.9{+-}0.6{+-}0.5)%.
In 2009, Lawrence Livermore National Laboratory (LLNL) engaged in several activities to support NA-24's Next Generation Safeguards Initiative (NGSI). This report outlines LLNL's efforts to support Human Capital Development (HCD), one of five key components of NGSI managed by Dunbar Lockwood in the Office of International Regimes and Agreements (NA-243). There were five main LLNL summer safeguards HCD efforts sponsored by NGSI: (1) A joint Monterey Institute of International Studies/Center for Nonproliferation Studies-LLNL International Safeguards Policy and Information Analysis Course; (2) A Summer Safeguards Policy Internship Program at LLNL; (3) A Training in Environmental Sample Analysis for IAEA Safeguards Internship; (4) Safeguards Technology Internships; and (5) A joint LLNL-INL Summer Safeguards Lecture Series. In this report, we provide an overview of these five initiatives, an analysis of lessons learned, an update on the NGSI FY09 post-doc, and an update on students who participated in previous NGSI-sponsored LLNL safeguards HCD efforts.
Although a comprehensive understanding of the basic properties of most elemental solids has been achieved, there are still fundamental, open questions regarding simple substances, e.g. boron. Based on an Ising model that describes the intrinsic defect states in elemental boron, we show that this system is the only known element to exhibit geometrical frustration in its solid form. Interestingly, we find that the peculiar transport properties of boron that have been reported over the past forty years originate from the presence of geometrical frustration.
Using a sample of 2.59x10{sup 7} {psi}(2S) decays collected by the CLEO-c detector, we present results of a study of {chi}{sub c0} and {chi}{sub c2} decays into two-meson final states. We present the world's most precise measurements of the {chi}{sub cJ,(J=0,2)}{yields}{pi}{sup +}{pi}{sup -}, {pi}{sup 0}{pi}{sup 0}, K{sup +}K{sup -}, K{sub S}{sup 0}K{sub S}{sup 0}, {eta}{eta}, and {eta}{sup '}{eta}{sup '} branching fractions, and a search for {chi}{sub c} decays into {eta}{eta}{sup '}. These results shed light on the mechanism of charmonium decays into pseudoscalar mesons.
This project has been focused on the development of accurate computational tools to study fluids in confined, nanoscale geometries, and the application of these techniques to probe the structural and electronic properties of water confined between hydrophilic and hydrophobic substrates, including the presence of simple ions at the interfaces. In particular, we have used a series of ab-initio molecular dynamics simulations and quantum Monte Carlo calculations to build an understanding of how hydrogen bonding and solvation are modified at the nanoscale. The properties of confined water affect a wide range of scientific and technological problems - including protein folding, cell-membrane flow, materials properties in confined media and nanofluidic devices.
Using {psi}(2S){yields}{pi}{sup +}{pi}{sup -}J/{psi}, J/{psi}{yields}{gamma}{eta}{sup '} events acquired with the CLEO-c detector at the CESR e{sup +}e{sup -} collider, we make the first observations of the decays {eta}{sup '}{yields}{pi}{sup +}{pi}{sup -}{pi}{sup 0} and {eta}{sup '}{yields}{pi}{sup +}{pi}{sup -}e{sup +}e{sup -}, measuring absolute branching fractions (37{sub -9}{sup +11}{+-}4)x10{sup -4} and (25{sub -9}{sup +12}{+-}5)x10{sup -4}, respectively. For {eta}{sup '}{yields}{pi}{sup +}{pi}{sup -}{pi}{sup 0}, this result probes the mechanism of isospin violation and the roles of {pi}{sup 0}/{eta}/{eta}{sup '}-mixing and final state rescattering in strong decays. We also set upper limits on branching fractions for {eta}{sup '} decays to {pi}{sup +}{pi}{sup -}{mu}{sup +}{mu}{sup -}, 2({pi}{sup +}{pi}{sup -}), {pi}{sup +}{pi}{sup -}2{pi}{sup 0}, 2({pi}{sup +}{pi}{sup -}){pi}{sup 0}, 3({pi}{sup +}{pi}{sup -}), and invisible final states.