Engineering Papers⌕ Search

Engineering topics

Ravikumar, Arvind P.

Publications and source records attributed to Ravikumar, Arvind P..

Methane Quantification Performance of the Quantitative Optical Gas Imaging (QOGI) System Using Single-Blind Controlled Release Assessment

Quantitative optical gas imaging (QOGI) system can rapidly quantify leaks detected by optical gas imaging (OGI) cameras across the oil and gas supply chain. A comprehensive evaluation of the QOGI system’s quantification capability is needed for the successful adoption of the technology. This study conducted single-blind experiments to examine the quantification performance of the FLIR QL320 QOGI system under near-field conditions at a pseudo-realistic, outdoor, controlled testing facility that mimics upstream and midstream natural gas operations. The study completed 357 individual measurements across 26 controlled releases and 71 camera positions for release rates between 0.1 kg Ch 4 /h and 2.9 kg Ch 4 /h of compressed natural gas (which accounts for more than 90% of typical component-level leaks in several production facilities). The majority (75%) of measurements were within a quantification factor of 3 (quantification error of –67% to 200%) with individual errors between –90% and 831%, which reduced to –79% to +297% when the mean of estimates of the same controlled release from multiple camera positions was considered. Performance improved with increasing release rate, using clear sky as plume background, and at wind speeds ≤1 mph relative to other measurement conditions.

42 ENGINEERING↗

Closing the methane gap in US oil and natural gas production emissions inventories

Methane (CH 4 ) emissions from oil and natural gas (O&NG) systems are an important contributor to greenhouse gas emissions. In the United States, recent synthesis studies of field measurements of CH 4 emissions at different spatial scales are ~1.5–2× greater compared to official greenhouse gas inventory (GHGI) estimates, with the production-segment as the dominant contributor to this divergence. Based on an updated synthesis of measurements from component-level field studies, we develop a new inventory-based model for CH 4 emissions, for the production-segment only, that agrees within error with recent syntheses of site-level field studies and allows for isolation of equipment-level contributions. We find that unintentional emissions from liquid storage tanks and other equipment leaks are the largest contributors to divergence with the GHGI. If our proposed method were adopted in the United States and other jurisdictions, inventory estimates could better guide CH 4 mitigation policy priorities.

03 NATURAL GAS↗

Sensor Placement Optimization Software Applied to Site-Scale Methane-Emissions Monitoring

Advances in sensor technology have increased our ability to monitor a wide range of environments. However, even as the cost of sensors decline, only a limited number of sensors can be installed at any given site. The physical placement of sensors, along with the sensor technology and operating conditions, can have a large impact on our ability to adequately monitor environmental change. This paper introduces a new open-source Python package, called Chama, that determines optimal sensor placement and technology to improve a sensor network’s detection capabilities. Additionally, the methods are demonstrated using site-specific methane emission scenarios that capture uncertainty in wind conditions and emission characteristics. Mixed-integer linear programming formulations are used to determine sensor locations and detection thresholds that maximize detection of the emission scenarios. The optimized sensor networks consistently increase the ability to detect leaks, as compared to sensors placed near each potential emission source or along the perimeter of the site.

47 OTHER INSTRUMENTATION↗