U.S. Manufacturing Water Use Data and Estimates: Current State, Limitations, and Future Needs for Supporting Manufacturing Research and Development

Water is essential to manufacturing operations; without it, many facilities could not operate or meet production demands. Physical, reputational, and regulatory risks to water supplies compounded by climate change-induced impacts on hydrological conditions threaten the adequacy of water supplies for manufacturing. Manufacturing water use has not been a major focus of either water or manufacturing-related research. Research and development (R&D) aimed at helping manufacturers use water more sustainably and adapt to changing water conditions is needed to ensure a thriving sector and economy. However, the ability to identify R&D needs is severely limited due to a lack of current, statistically representative data on manufacturing water use and its environmental implications. In this Perspective, we outline four key questions to inform R&D on manufacturing use and highlight how the current state of water data in the United States does not support the adequate investigation of these questions. We make recommendations for the water data characteristics needed to explore the research questions and knowledgeably inform R&D on manufacturing water use.

McCall, James↗

Survey of Available Information on U.S. Manufacturing Wastewater and Energy Requirements for Reuse

This report seeks to inform an improved understanding of the energy tradeoff associated with manufacturing water reuse in the United States, in part by developing an analytical framework for understanding when this tradeoff for reuse is beneficial. In order to apply this approach, existing literature and publicly available information on typical contaminants in industrial effluent and available treatment technologies are reviewed and summarized. An existing case study is then discussed in light of how the analytical framework could be applied if sufficient data were available. We conclude that the shortcomings of the available data severely restrict our ability to apply this framework. These limitations are highlighted with the intent of providing the broader research community information on where data gaps need to be filled.

54 ENVIRONMENTAL SCIENCES↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 2: Advanced Motors and Drives Supply Chain Review

Electric motors in commercial and industrial applications account for almost a third of total electric grid load in the United States. With these applications representing such a significant level of energy use, increasing efficiency in these applications can help substantially increase resilience and lower total energy costs. This report examines stationary high-efficiency electric motor technologies and their supply chains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Future of Water Infrastructure and Innovation Summit

Energy and water systems are interdependent, and the U.S. Department of Energy (DOE) has invested in energy and water for several years, including the Energy-Water Desalination Hub (led by the National Alliance for Water Innovation, NAWI), and research and development (R&D) in resource recovery from wastewater, among other areas. The Advanced Manufacturing Office (AMO) at the U.S. Department of Energy (DOE) held The Future of Water Infrastructure and Innovation Summit to inform the understanding of future opportunities in the water space. The virtual summit was held on October 27 and 28, 2020. The organizers gathered information from a diverse group of relevant water and wastewater stakeholders representing academia, industry, government, nongovernmental organizations, and local/regional utilities. Topics from Day 1 discussions included: desalination, water and wastewater treatment/recovery, produced water, industrial management of water, and hydropower, conveyance, and water systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterizing manufacturing wastewater in the United States for the purpose of analyzing energy requirements for reuse

This paper seeks to inform an improved understanding of the energy tradeoff associated with on-site manufacturing water reuse in the United States from a lifecycle perspective, in part by developing an analytical framework for understanding when this tradeoff for reuse is beneficial. We survey the literature to assess the current state of reuse and its motives and barriers in the United States, before synthesizing information from publicly available EPA data on contaminants in US manufacturing wastewaters and technologies for treating them. Using the available data, we derive a set of “ubiquitous contaminants” among the top ten in terms of mass discharged in more than half of US manufacturing subsectors (NAICS 31–33) according to EPA permit data. We also present information on proven treatment trains and their energy requirements. We then compare water quality requirements for specific contaminants in reclaimed water to those characteristic of wastewater streams currently being discharged from manufacturing plants into surface waters to highlight sectors with reuse opportunities that could require little cost to realize, such as primary metals and, to a lesser extent, petroleum and coal products. We conclude by highlighting data limitations that need to be rectified before applying the framework more broadly and discussing how these data gaps could be filled. Better understanding the relationship between energy and water in the context of on-site manufacturing water reuse would allow manufacturers to improve resiliency by reducing regulatory, physical, and reputational risks while lessening their footprint on local watersheds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of U.S. Manufacturing Subsectors at Risk of Physical Water Shortages

The potential impact of water shortages on U.S. manufacturing is unknown. While water for manufacturing constitutes an estimated 6% of U.S. water intake, the data (i.e., location, quantity, and purpose of water intake) needed to determine this impact does not exist. This paper will identify manufacturing subsectors at risk of physical water shortages by applying a method for estimating U.S. manufacturing water intake at the necessary spatial and sectoral resolutions. First, the data requirements to quantify a manufacturing facility’s water footprint within the context of the watershed are developed. Second, using international data, water intake at the national, state, and county-levels by each U.S. manufacturing subsector is estimated. Third, manufacturing subsectors that are most vulnerable to risks of physical water shortages are identified. Based on the results, the Paper, Primary Metals, Chemical, Petroleum and Coal Products, and Food subsectors have the largest intake, respectively. However, the Primary Metals, Fabricated Metals, Transportation Equipment, Petroleum and Coal Products, and Plastics and Rubber subsectors are at the greatest risk of physical water shortages based on concentrations of water intake in water-stressed regions. Lastly, the results can be used to develop strategies to mitigate the risks of water shortages on the U.S. manufacturing sector.

54 ENVIRONMENTAL SCIENCES↗

Energy considerations associated with increased adoption of seawater desalination in the United States

Due in part to increased water demand and uncertainty around the availability of existing freshwater resources, there is interest in expanding the use of seawater desalination in the U.S. In order for greater adoption to occur, existing barriers need to be mitigated. One of these barriers is the energy consumption of seawater desalination. This paper reviews the existing energy requirements for membrane and thermal-based seawater desalination systems to produce potable water. Through literature review, it identifies the commercially-available option with the lowest energy intensity and the thermodynamic minimum energy requirement for each unit operation of the system. The paper then estimates the energy requirements to expand seawater desalination capacity to meet the potable water needs of water-stressed regions in the U.S. The results show that supplying 10% of the potable water demand for these regions located within 250 miles of a coastline using the lowest energy-intensity seawater desalination system commercially available would require <0.1% of 2018 U.S. electricity consumption. This increases to approximately 0.5% if all public water for these same regions is supplied via desalinated seawater. Furthermore, these estimates of the energy implications of broader adoption provide an initial comparison to current U.S. electricity consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting the quantifiable impacts of ISO 50001 on climate change mitigation

The ISO 50001-Energy management standard provides a continual improvement framework for organizations to reduce their energy consumption, which in the industrial and commercial (service) sectors, accounts for nearly 40% of global greenhouse gas emissions. Reducing this energy consumption will be critical for countries to achieve their national greenhouse gas reduction commitments. Several national policies already support ISO 50001; however, there is no transparent, consistent process to estimate the potential impacts of its implementation. This paper presents the ISO 50001 Impacts Methodology, an internationally-developed methodology to calculate these impacts at a national, regional, or global scale suitable for use by policymakers. The recently-formed ISO 50001 Global Impacts Research Network provides a forum for policymakers to refine and encourage use of the methodology. Using this methodology, a scenario with 50% of projected global industrial and service sector energy consumption under ISO 50001 management by 2030 would generate cumulative primary energy savings of approximately 105 EJ, cost savings of nearly US $700 billion (discounted to 2016 net present value), and 6500 million metric tons (Mt) of avoided CO 2 emissions. The avoided annual CO 2 emissions in 2030 alone are equivalent to removing 210 million passenger vehicles from the road.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ISO 50001 and SEP Faster and Cheaper - Exploring the Enterprise-Wide Approach

ISO 50001 and other management systems (e.g., ISO 9001 and ISO 14001) allow for implementation and certification at the enterprise level. The "Central Office" concept, which allows a small group of employees to manage and facilitate the organization’s energy management system (EnMS) at the enterprise level, was introduced within the ISO 50003 standard to provide guidance to ISO 50001 certification bodies. Four industrial companies have partnered with the United States Department of Energy to pilot the enterprise-wide ISO 50001/SEP concept under the Better Buildings Superior Energy Performance (SEP) Enterprise-wide Accelerator. Each organization developed a Central Office to host their EnMS while implementing ISO 50001/SEP at multiple physically separated sites. The four corporate partners tailored their Central Office implementation model to meet their own specific circumstances and needs. This paper reviews the commonalities, differences, and benefits of each of these enterprise-wide implementation models, including organizational structures, Central Office staff responsibilities, and key strategies. The cost savings and benefits of using the enterprise-wide approach were assessed, including the cost per site compared with that of a conventional, single-site ISO 50001/SEP implementation approach. This paper also discusses the drivers for the cost reductions realized through these enterprise-wide approaches. The four partner companies worked with 30 total sites. On average, these 30 sites improved energy performance by 5% annually over their SEP achievement periods, saved more than $600,000 annually in energy costs and reduced implementation cost for ISO 50001 and SEP by $19,000 and 0.8 Full Time Equivalent × years (FTE-yr) of staff time per site. The results can inform other organizations seeking to implement enterprise-wide ISO 50001/SEP, as well as energy efficiency organizations seeking to promote wider adoption of ISO 50001 implementation.

97 MATHEMATICS AND COMPUTING↗

Volume 1: Survey of Available Information in Support of the Energy-Water Bandwidth Study of Desalination Systems

The U.S. Department of Energy (DOE) has set a goal to reduce the cost of seawater desalination systems to $0.50/ cubic meter (m 3 ) through the development of technology pathways to reduce energy, capital, operating, soft, and system integration costs.1 In support of this goal and to evaluate the technology pathways to lower the energy and carbon intensity of desalination while also reducing the total water cost, DOE is undertaking a comprehensive study of the energy consumption and carbon dioxide (CO 2 ) emissions for desalination technologies and systems. This study is being undertaken in two phases. Phase 1, Survey of Available Information in Support of the Energy-Water Bandwidth Study of Desalination Systems, collected the background information that will underpin Phase 2, the Energy Water Bandwidth Study for Desalination Systems. This report (Volume 1) summarizes the results from Phase 1. The results from Phase 2 will be summarized in Volume 2: Energy Water Bandwidth Study for Desalination Systems (Volume 2). The analysis effort for Phase 2 will utilize similar methods as other industry-specific Energy Bandwidth Studies developed by DOE,2 which has provided a framework to evaluate and compare energy savings potentials within and across manufacturing sectors at the macroscale. Volume 2 will assess the current state of desalination energy intensity and reduction potential through the use of advanced and emerging technologies. For the purpose of both phases of study, energy intensity is defined as the amount of energy required per unit of product water output (for example, kilowatt-hours per cubic meter of water produced). These studies will expand the scope of previous sectorial bandwidth studies by also evaluating CO 2 intensity and reduction opportunities and informing a techno-economic analysis of desalination systems. Volume 2 is expected to be completed in 2017.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Value of Regression Models in Determining Industrial Energy Savings

Determination of industrial facility energy savings is commonly undertaken to comply with legal requirements, meet sustainability goals, and quantify greenhouse gas emissions, cost savings, and as one way to demonstrate energy performance improvement per the requirements of an energy management system standard, such as ISO 50001. At their most basic level, energy savings are determined through a process of accounting for baseline and reporting period energy consumption followed by a calculation of energy savings as the difference in the levels of energy consumption between the two periods. The determination of industrial facility-wide energy savings can be undertaken in a wide variety of ways and in relation to energy performance improvement, energy savings can be expressed as any number of energy performance indicators (EnPIs). Energy savings values will vary depending upon if an absolute, intensity, or regression basis of calculation is selected for use. The use of one of the three basis of energy savings calculation will alter the relevance, meaning, and comparability of the resulting energy savings values To increase consistency in the determination of energy savings values, standards such as the International Performance Measurement and Verification Protocol (IPMVP), ISO 17747 – Determination of Energy Savings in Organization, and the U.S. Department of Energy (U.S. DOE) Superior Energy Performance (SEP) program Measurement and Verification Protocol (SEP M&V Protocol) have been published. Industrial facilities in the United States, Mexico, and Canada are certified to the U.S. DOE SEP program after becoming ISO 50001 certified and verification by a third party of calculated energy savings per the SEP M&V Protocol. This paper discusses some of the different meanings energy savings values will have when calculated by using the three different bases. Additionally, data from five SEP certified industrial facilities are used to calculate energy savings values using the three bases and compared as energy performance improvement percentage (EPI %) values. Discussion of why a large degree in variation in EPI % values are seen for any given set of data is provided. Ultimately, while each energy saving calculation basis has merit and can be used appropriately in its own context, the regression basis is shown to best translates energy savings values into contextualized energy performance improvement values by conveying comparable information regarding operational and behavioural improvements not otherwise observable with the absolute or intensity bases.

Therkelsen, Peter↗

The ISO 50001 Impact Estimator Tool (IET 50001 V1.1.4) - User Guide and Introduction to the ISO 50001 Impacts Methodology

ISO 50001-Energy management systems – Requirements with guidance for use, is an internationally developed standard that provides organizations with a flexible framework for implementing an energy management system (EnMS) with the goal of continual energy performance improvement. The ISO 50001 standard was first published in 2011 and has since seen growth in the number of certificates issued around the world, primarily in the industrial (agriculture, manufacturing, and mining) and service (commercial) sectors. Policy makers in many regions and countries are looking to or are already using ISO 50001 as a basis for energy efficiency, carbon reduction, and other energy performance improvement schemes. The Impact Estimator Tool 50001 (IET 50001 Tool) is a computational model developed to assist researchers and policy makers determine the potential impact of ISO 50001 implementation in the industrial and service (commercial) sectors for a given region or country. The IET 50001 Tool is based upon a methodology initially developed by the Lawrence Berkeley National Laboratory that has been improved upon and vetted by a group of international researchers. By using a commonly accepted and transparent methodology, users of the IET 50001 Tool can easily and clearly communicate the potential impact of ISO 50001 for a region or country.

97 MATHEMATICS AND COMPUTING↗

Global Impact Estimation of ISO 50001 Energy Management System for Industrial and Service Sectors

A methodology has been developed to determine the impacts of ISO 50001 Energy Management System (EnMS) at a region or country level. The impacts of ISO 50001 EnMS include energy, CO2 emissions, and cost savings. This internationally recognized and transparent methodology has been embodied in a user friendly Microsoft Excel® based tool called ISO 50001 Impact Estimator Tool (IET 50001). However, the tool inputs are critical in order to get accurate and defensible results. This report is intended to document the data sources used and assumptions made to calculate the global impact of ISO 50001 EnMS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing Energy Efficiency Opportunities in US Industrial and Commercial Building Motor Systems

In 2002, the United States Department of Energy (USDOE) published an energy efficiency assessment of U.S. industrial sector motor systems titled United States Industrial Electric Motor Systems Market Opportunities Assessment. The assessment advanced motor system efficiency by providing a greater understanding of the energy consumption, use characteristics, and energy efficiency improvement potential of industrial sector motor systems in the U.S. Since 2002, regulations such as Minimum Energy Performance Standards, cost reductions for motor system components such as variable frequency drives, system-integrated motor-driven equipment, and awareness programs for motor system energy efficiency have changed the landscape of U.S. motor system energy consumption. To capture the new landscape, the USDOE has initiated a three-year Motor System Market Assessment (MSMA), led by Lawrence Berkeley National Laboratory (LBNL). The MSMA will assess the energy consumption, operational and maintenance characteristics, and efficiency improvement opportunity of U.S. industrial sector and commercial building motor systems. As part of the MSMA, a significant effort is currently underway to conduct field assessments of motor systems from a sample of facilities representative of U.S. commercial and industrial motor system energy consumption. The Field Assessment Plan used for these assessments builds on recent LBNL research presented at EEMODS 2011 and EEMODS 2013 using methods for characterizing and determining regional motor system energy efficiency opportunities. This paper provides an update on the development and progress of the MSMA, focusing on the Field Assessment Plan and the framework for assessing the global supply chain for emerging motors and drive technologies.

Rao, Prakash↗

Development of an Enhanced Payback Function for the Superior Energy Performance Program

The U.S. DOE Superior Energy Performance (SEP) program provides recognition to industrial and commercial facilities that achieve certification to the ISO 50001 energy management system standard and third party verification of energy performance improvements. Over 50 industrial facilities are participating and 28 facilities have been certified in the SEP program. These facilities find value in the robust, data driven energy performance improvement result that the SEP program delivers. Previous analysis of SEP certified facility data demonstrated the cost effectiveness of SEP and identified internal staff time to be the largest cost component related to SEP implementation and certification. This paper analyzes previously reported and newly collected data of costs and benefits associated with the implementation of an ISO 50001 and SEP certification. By disaggregating “sunk energy management system (EnMS) labor costs”, this analysis results in a more accurate and detailed understanding of the costs and benefits of SEP participation. SEP is shown to significantly improve and sustain energy performance and energy cost savings, resulting in a highly attractive return on investment. To illustrate these results, a payback function has been developed and is presented. On average facilities with annual energy spend greater than $2M can expect to implement SEP with a payback of less than 1.5 years. Finally, this paper also observes and details decreasing facility costs associated with implementing ISO 50001 and certifying to the SEP program, as the program has improved from pilot, to demonstration, to full launch.

Therkelsen, Peter↗