Engineering PapersSearch

Engineering topics

Rahman, Zahidul H.

Publications and source records attributed to Rahman, Zahidul H..

An Overview of the Formation and Attitude Control System for the Terrestrial Planet Finder Formation Flying Interferometer

The Terrestrial Planet Finder formation flying Interferometer (TPF-I) will be a five-spacecraft, precision formation operating near a Sun-Earth Lagrange point. As part of technology development for TPF-I, a formation and attitude control system (FACS) is being developed that achieves the precision and functionality associated with the TPF-I formation. This FACS will be demonstrated in a distributed, real-time simulation environment. In this paper we present an overview of the FACS and discuss in detail its constituent formation estimation, guidance and control architectures and algorithms. Since the FACS is currently being integrated into a high-fidelity simulation environment, component simulations demonstrating algorithm performance are presented.

Terrestrial Planet Finder (TPF)

An Overview of the Formation and Attitude Control System for the Terrestrial Planet Finder Formation Flying Interferometer

The Terrestrial Planet Finder formation flying Interferometer (TPF-I) will be a five-spacecraft, precision formation operating near the second Sun-Earth Lagrange point. As part of technology development for TPF-I, a formation and attitude control system (FACS) is being developed that achieves the precision and functionality needed for the TPF-I formation and that will be demonstrated in a distributed, real-time simulation environment. In this paper we present an overview of FACS and discuss in detail its formation estimation, guidance and control architectures and algorithms. Since FACS is currently being integrated into a high-fidelity simulation environment, component simulations demonstrating algorithm performance are presented.

Scharf, Daniel P.

Multilayer Active Control For Structural Damping And Optical-Path Regulation

Two active-control concepts incorporated into system for suppression of vibrations in truss structure and regulation of length of optical path on structure to nanometer level. Optical-path-length-control subsystem contains two feedback control loops to obtain active damping in wide amplitude-and-frequency range. Concept described in more detail in number of previous articles, including "Stabilizing Optical-Path Length on a Vibrating Structure" (NPO-19040), "Controllable Optical Delay Line for Stellar Interferometry" (NPO-18686), "Test Bed for Control of Optical-Path Lengths" (NPO-18487).

Rahman, Zahidul H.

Stabilizing Optical Path Length On A Vibrating Structure

Prototype apparatus constructed to test feasibility of feedback control concept for stabilization of length of optical path between two points on vibrating flexible structure. In original intended application, structure is truss having dimensions of order of meters and supports optical components of stellar interferometer. Interferometry and feedback control reduce path-length disturbances. Some aspects of present feedback control concept and prototype apparatus described in "Controllable Optical Delay Line for Stellar Interferometry" (NPO-18686), and "Test Bed for Control of Optical-Path Lengths" (NPO-18487).

Spanos, John T.

Optical pathlength control on the JPL Phase B interferometer testbed

Design and implementation of a controller for optical pathlength compensation on a flexible structure is presented. Nanometer level pathlength control is demonstrated in the laboratory. The experimental results are in close agreement with performance predictions.

Spanos, John T.

Optical pathlength control experiment on JPL phase B testbed

An experimental implementation of a nanometer level optical pathlength control for large baseline space interferometry is presented. The pathlength compensation system is installed on a large flexible experimental truss, thus structural motions play a dominant role in the control system design. The associated control structure interaction problem is addressed to maintain the optical pathlength within the prescribed variation of 10-15 nanometer rms. By a successful blend of a structural control for damping augmentation and a direct pathlength control for the pathlength compensation, the optical pathlength variation has been maintained with 6 nanometer rms under the laboratory ambient disturbance and within 9 nanometer rms under a severe forced resonant disturbance.

Rahman, Zahidul H.