Engineering Papers⌕ Search

Engineering topics

Radev, Radoslav

Publications and source records attributed to Radev, Radoslav.

Characterization of 244 Cm Neutron Sources

There is a need to find a replacement for the 252 Cf sources currently used in Standards-based performance testing of neutron instrumentation. This is a result of its relatively short half-life, concerns about future availability and recent increases in cost. A potential replacement source, 244 Cm is evaluated in this study where two commercially available sources have been acquired and their neutron emission spectra measured using a pair of spectrometers. Both instruments showed the 244 Cm spontaneous neutron spectrum to be fully consistent with a MCNP6®-calculated spectrum using published Watt fission parameters for 244 Cm. In addition, the emission rate of the weaker 244 Cm source was established through a direct count rate comparison against a calibrated and similarly encapsulated 252 Cf source. The 244 Cm source emission rate was found to be in excellent agreement with value stated on the manufacturer's source certificate. It is concluded that 244 Cm would be an ideal replacement for 252 Cf based on its longer half-life (18.1 y) and its essentially identical neutron emission spectrum. In addition, 244 Cm sources are commercially available at reasonable cost.

244Cm↗

Neutron Sources for Standard-Based Testing

The DHS TC Standards and the consensus ANSI Standards use 252 Cf as the neutron source for performance testing because its energy spectrum is similar to the 235 U and 239 Pu fission sources used in nuclear weapons. An emission rate of 20,000 ± 20% neutrons per second is used for testing of the radiological requirements both in the ANSI standards and the TCS. Determination of the accurate neutron emission rate of the test source is important for maintaining consistency and agreement between testing results obtained at different testing facilities. Several characteristics in the manufacture and the decay of the source need to be understood and accounted for in order to make an accurate measurement of the performance of the neutron detection instrument. Additionally, neutron response characteristics of the particular instrument need to be known and taken into account as well as neutron scattering in the testing environment.

07 ISOTOPE AND RADIATION SOURCES↗

2010 Annual Health Physics Report for the HEU Transparency Program

During the 2010 calendar year, Lawrence Livermore National Laboratory (LLNL) provided health physics support for the Highly Enriched Uranium (HEU) Transparency Program for external and internal radiation protection. LLNL also provided technical expertise related to BDMS radioactive sources and Russian radiation safety regulatory compliance. For the calendar year 2010, there were 141 person-trips that required dose monitoring of the U.S. monitors. Of the 141 person-trips, 129 person-trips were Special Monitoring Visits (SMVs) and 12 person-trips were Transparency Monitoring Office (TMO) trips. In 8 of these TMO trips the TMO monitors participated also in the UEIE SMVs and in 2 TMO trips the TMO monitors participated in UEIE and MPA SMVs. There were three monitoring visits (source changes) that were back-to-back SMVs with a total of 25 monitors. LLNL’s Hazard Control Department laboratories provided the dosimetry services for the HEU Transparency monitors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of the Neutron Fields in the Lawrence Livermore National Laboratory (LLNL) Radiation Calibration Laboratory Low Scatter Facility

The issuance of Part 10 CFR 835 (2007) with revised radiation weighting factors and the installation of a new Hopewell N40 irradiator necessitated a re-characterization of the neutron fields in RCL's Low Scatter Calibration Facility (B255, Room 183 A). The emission rates of the RCL's two 252 Cf calibration sources were re-evaluated and the updated emission rates are provided in Appendix A. The neutron dose rates from the new Hopewell N40 irradiator configuration were evaluated using three different instruments. the measurement methodology and the experimental set up as well as calibration of the instruments are discussed in detail.

61 RADIATION PROTECTION AND DOSIMETRY↗