Engineering Papers⌕ Search

Engineering topics

Quinn, Heather Marie

Publications and source records attributed to Quinn, Heather Marie.

At least 19 records

Accelerated Nuclear Radiation Effects on the Raspberry Pi 3B+ and Pi 4

Raspberry Pi™ computers running Linux and embedded benchmarks are subjected to radiation testing in the neutron beam at LANSCE. The ARM® Cortex®-A53 in the Raspberry Pi 3B+ versus ARM® Cortex®-A72 in the Raspberry Pi 4, single-core versus multi-core, and small versus large array SBU cross sections are compared. Results for the A53 and the A72 are similar. The results of one process on one of four cores and four identical processes on four cores are presented. The results of the array size show that there is more going on than just an increase in size. Linux is helpful in relating some errors that would have been classified as SEFI to an upset in a single bit.

36 MATERIALS SCIENCE↗

Perseverance’s Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) Investigation

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) is a robotic arm-mounted instrument on NASA’s Perseverance rover. SHERLOC has two primary boresights. The Spectroscopy boresight generates spatially resolved chemical maps using fluorescence and Raman spectroscopy coupled to microscopic images (10.1 μm/pixel). The second boresight is a Wide Angle Topographic Sensor for Operations and eNgineering (WATSON); a copy of the Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) that obtains color images from microscopic scales (~13 μm/pixel) to infinity. SHERLOC Spectroscopy focuses a 40 μs pulsed deep UV neon-copper laser (248.6 nm), to a ~100 μm spot on a target at a working distance of ~48 mm. Fluorescence emissions from organics, and Raman scattered photons from organics and minerals, are spectrally resolved with a single diffractive grating spectrograph with a spectral range of 250 to ~370 nm. Because the fluorescence and Raman regions are naturally separated with deep UV excitation (<250 nm), the Raman region ~ 800 – 4000 cm -1 (250 to 273 nm) and the fluorescence region (274 to ~370 nm) are acquired simultaneously without time gating or additional mechanisms. SHERLOC science begins by using an Autofocus Context Imager (ACI) to obtain target focus and acquire 10.1 μm/pixel greyscale images. Chemical maps of organic and mineral signatures are acquired by the orchestration of an internal scanning mirror that moves the focused laser spot across discrete points on the target surface where spectra are captured on the spectrometer detector. ACI images and chemical maps (< 100 μm/mapping pixel) will enable the first Mars in situ view of the spatial distribution and interaction between organics, minerals, and chemicals important to the assessment of potential biogenicity (containing CHNOPS). Single robotic arm placement chemical maps can cover areas up to 7x7 mm in area and, with the < 10 min acquisition time per map, larger mosaics are possible with arm movements. This microscopic view of the organic geochemistry of a target at the Perseverance field site, when combined with the other instruments, such as Mastcam-Z, PIXL, and SuperCam, will enable unprecedented analysis of geological materials for both scientific research and determination of which samples to collect and cache for Mars sample return.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OrganiCam: a lightweight time-resolved laser-induced luminescence imager and Raman spectrometer for planetary organic material characterization

OrganiCam is a laser-induced luminescence imager and spectrometer designed for standoff organic and biosignature detection on planetary bodies. OrganiCam uses a diffused laser beam (12° cone) to cover a large area at several meters distance and records luminescence on half of its intensified detector. The diffuser can be removed to record Raman and fluorescence spectra from a small spot from 2 m standoff distance. OrganiCam’s small size and light weight makes it ideal for surveying organics on planetary surfaces. Here, we have designed and built a brassboard version of the OrganiCam instrument and performed initial tests of the system.

47 OTHER INSTRUMENTATION↗

Radiation Effects on Electronics: How to Destroy a Satellite in Three Easy Steps [Slides]

This report contains a set of slides intended for a summer school at Los Alamos National Laboratory (LANL). On the topic of radiation effect on electronics, this presentation provides a brief overview of transistors and discusses Total Ionizing Dose (TID), Displacement Damage (DD) or Total Non-ionizing Dose (TNID), and Single-Event Effects (SEEs) in relation to radiation effects for satellites.

42 ENGINEERING↗

Subatomic Particles, Radiation Effects [Slides]

This set of slides, intended for a presentation at a summer school, discusses the radiation effects of subatomic particles. It discusses single-event effects including types, indirect ionization, a cross-section, the range, angular effects, and concludes by providing Poisson examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

JESD89 Test Standard [Slides]

This report contains a set of slides discussing JESD89A, specifically the revision of JESD89 from August 2001, intended for a presentation at a summer school at Los Alamos National Laboratory (LANL). It discusses how tests are designed and the different types of tests implemented, including real time testing, alpha testing, fast neutron testing, and thermal neutron testing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Effect of 1–10-MeV Neutrons on the JESD89 Test Standard

Here, the JESD89 test standard defines how terrestrial neutron testing is conducted [1] . The test standard covers a number of different types of radiation used for testing, including protons, neutrons, and alphas, and different types of testing, including life testing and accelerated testing. Broad-spectrum neutron testing is the most common type of accelerated radiation testing for the terrestrial radiation environment. Unlike most test standards, the JESD89 defines the minimum energy for determining the cumulative fluence for the deployed and test environment. Currently, the minimum energy is set at 10 MeV. As the test standard is currently being rewritten, changing the minimum energy to 1 MeV is being explored, because it is believed that the onset to neutron-induced single-event effects (SEEs) is less than 10 MeV. There are three separate problems with lowering the minimum energy: determining whether electronics have a sensitivity to neutron-induced SEEs below 10 MeV, determining whether the test spectra match the terrestrial environment in the 1–10-MeV range, and the measurement error caused by not including the fluence from 1 to 10 MeV. In this paper, we present information on these factors and whether the minimum energy should be lowered to 1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Robust Duplication with Comparison Methods in Microcontrollers

Commercial microprocessors could be useful computational platforms in space systems, as long as the risk is bound. Many spacecraft are computationally constrained because all of the computation is done on a single radiation-hardened microprocessor. It is possible that a commercial microprocessor could be used for configuration, monitoring and background tasks that are not mission critical. Most commercial microprocessors are affected by radiation, including single-event effects (SEEs) that could be destructive to the component or corrupt the data. Part screening can help designers avoid components with destructive failure modes, and mitigation can suppress data corruption. We have been experimenting with a method for masking radiation-induced faults through the software executing on the microprocessor. While triple-modular redundancy (TMR) techniques are very effective at masking faults in software, the increased amount of execution time to complete the computation is not desirable. Here in this article we present a technique for combining duplication with compare (DWC) with TMR that decreases observable errors by as much as 145 times with only a 2.35 time decrease in performance.

97 MATHEMATICS AND COMPUTING↗

Analyzing the effectiveness of a frame-level redundancy scrubbing technique for SRAM-based FPGAs

Radiation effects such as soft errors are the major threat to the reliability of SRAM-based FPGAs. This work analyzes the effectiveness in correcting soft errors of a novel scrubbing technique using internal frame redundancy called Frame-level Redundancy Scrubbing (FLR-scrubbing). This correction technique can be implemented in a coarse grain TMR design. The FLR-scrubbing technique was implemented on a mid-size Xilinx Virtex-5 FPGA device used as a case study. The FLR-scrubbing technique was tested under neutron radiation and fault injection. Implementation results demonstrated minimum area and energy consumption overhead when compared to other techniques. The time to repair the fault is also improved by using the Internal Configuration Access Port (ICAP). Lastly, neutron radiation test results demonstrated that the proposed technique is suitable for correcting accumulated SEUs and MBUs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗