Engineering Papers⌕ Search

Engineering topics

Qiu, Feng

Publications and source records attributed to Qiu, Feng.

At least 55 records · Page 3

Approximating Trajectory Constraints With Machine Learning – Microgrid Islanding With Frequency Constraints

Here, we introduce deep earning aided constraint encoding to tackle the frequency-constraint microgrid scheduling problem. The nonlinear function between system operating condition and frequency nadir is approximated by using a neural network, which admits an exact mixed-integer formulation (MIP). This formulation is then integrated with the scheduling problem to encode the frequency constraint. With the stronger representation power of the neural network, the resulting commands can ensure adequate frequency response in a realistic setting in addition to islanding success. The proposed method is validated on a modified 33-node system. Successful islanding with a secure response is simulated under the scheduled commands using a detailed three-phase model in Simulink. The advantages of our model are particularly remarkable when the inertia emulation functions from wind turbine generators are considered.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating Cascading Outages in Severe Weather Using Simulation-Based Optimization

Severe weather events can trigger cascading power outages and lead to significant losses. In this work, we investigate cascading outage mitigation under severe weather conditions. Given day-ahead weather forecasts and component failure models, we aim to identify a set of power lines that can be hardened to minimize the expected impact of potential cascading outages. Since the expected load shedding cannot be expressed as an explicit function of line hardening decisions and system states, we developed a cascading outage simulator to estimate the expected value of load shedding under various initial weather-related disruption scenarios generated using a weather forecast. To avoid massive enumeration of all possible combinations of line hardening decisions and reduce the simulation efforts, we employed an efficient simulation-based optimization approach that quickly identifies the (near) optimal line hardening decisions in the presence of both large simulation noises due to the highly variable initial disturbances and system states, and significant randomness in the subsequent cascades. Furthermore, the algorithm is also able to utilize parallel computing to dramatically reduce computation time to support decision making in preparation for severe weather conditions. We performed a case study on the Northeast Power Coordinating Council (NPCC) 140-bus system model to demonstrate that our approach can significantly improve power grid resilience to adverse weather events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient and Robust Dynamic Simulation of Power Systems With Holomorphic Embedding

Dynamic simulation is vitally important in power system analysis, but traditional approaches based on numerical integration over small time steps are time-consuming. Also, the Newton-Raphson method suffers from difficulty in convergence when solving nonlinear algebraic equations. In this paper, we propose a novel dynamic simulation approach based on holomorphic embedding. By obtaining a high-order approximation of system dynamics, it achieves a much larger time step and thus enhances the computational efficiency significantly. In addition, the new approach avoids non-convergence issues in solving algebraic equations, which improves robustness. The approach includes flexible modeling of synchronous generators and controllers, and we propose a method for modeling generator coordinate transformations. The approach is tested on the IEEE 39-bus, 10-generator system and a Polish 2383-bus, 327-generator system. The results demonstrate promising computational efficiency and satisfactory numerical robustness for the analysis of large-scale power systems.

42 ENGINEERING↗

PMU and Communication Infrastructure Restoration for Post-Attack Observability Recovery of Power Grids

This paper is concerned about recovering the observability of cyber-physical power grids after massive cyber attacks, which helps to achieve the cyber-physical resilience of the grids. For recovering the observability of the grid, the measurability of the Phasor Measurement Units (PMUs) and the connectivity of the communication network are needed to be restored. The PMU and communication infrastructure restoration problem is jointly formulated as a Mixed Integer Linear Programming (MILP) problem to minimize the observability loss of the grid over time after a cyber attack while considering the constraint of limited resources. The efficacy of the proposed optimal restoration strategy is verified by comparing with heuristic methods on the IEEE 57-bus system.

cyber security↗

Few-Layer Graphene Functionalized by Carbon Nanotubes and MnO{sub 2} Nanoparticles for High-Performance Supercapacitors

Few-layer graphene (FLG) exfoliated from graphite is an attractive electrode material due to its high conductivity and high chemical stability. But usually limited by their specific surface area (SSA), its capacitance needs to be improved when used in supercapacitors. In this study, FLG has been prepared by combining electrochemical exfoliation and thermal expansion. It has a SSA of 148 m{sup 2}/g and delivers a capacitance of 55 F/g at a discharge current density of 1 A/g. To increase its capacitance, carbon nanotubes (CNTs) and MnO{sub 2} nanoparticles are functionalized onto FLG surface separately. Both modification could achieve a composite electrode with enhanced capacitance. The CNT/FLG and MnO{sub 2}/FLG electrodes show a specific capacitance of 106 and 336 F/g at the current density of 1 A/g, respectively, while the former exhibits a much better rate performance and cycling stability than the latter. This work demonstrates an optional way to improve the performance of FLG-based supercapacitors.

36 MATERIALS SCIENCE↗

Transmission Constraint Filtering in Large-Scale Security-Constrained Unit Commitment

When solving the security-constrained unit commitment problem, one of the most complicating factors is handling the large number of transmission constraints, corresponding to both base case and N - 1 line contingency scenarios. Although it is well known that only a few of these constraints need to be enforced, identifying this critical subset of constraints efficiently remains a challenge. In this letter, we propose a novel and simple iterative contingency-screening procedure that is able to eliminate 99.4% of the constraints selected by existing iterative methods, allowing for the solution of much larger-scale problems. We report computational results in realistic instances with up to 6468 buses and 9000 transmission lines. Furthermore, the method was also independently implemented and evaluated at MISO, where it performed faster than alternative methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preparation and characterization of the Al-Cu-Mg-Si-Mn composites reinforced by different surface modified SiCp

Highlights: • The Ti-coated SiC{sub p} exhibited more uniformly distribution in composites than that of pre-oxidized SiC{sub p}. • Ti-coated SiC{sub p} obtained better SiC{sub p}-Al interface bonding than that of pre-oxidized SiC{sub p}. • The composites reinforced by Ti-coated SiC{sub p} exhibited better tensile properties than that reinforced by pre-oxidized SiC{sub p}. - Abstract: In this paper, the 4 vol% SiC{sub p}/Al-Cu-Mg-Si-Mn composites were prepared by method of stirring casting. The effects of SiC{sub p} surface modifications (oxidization and Ti-coating) and particle sizes (5 μm, 10 μm and 15 μm) on the microstructure and tensile properties of the composites were analyzed. The effects of SiC{sub p} sizes on the distribution of SiC{sub p} in the pre-oxidized SiC{sub p}/Al-Cu-Mg-Si-Mn composites were larger than those in Ti-coated SiC{sub p}/Al-Cu-Mg-Si-Mn composites. The Al-Cu-Mg-Si-Mn composites reinforced with Ti-coated SiC{sub p} exhibited more uniform SiC{sub p} distributions and higher tensile mechanical properties than those reinforced with the pre-oxidized SiC{sub p}. When the SiC{sub p} size was 15 μm, the Ti-coated SiC{sub p}/Al-Cu-Mg-Si-Mn composite showed the best yield strength (σ{sub 0.2}), ultimate tensile strength (σ{sub UTS}) and fracture strain (ε{sub f}) of 410 MPa, 548 MPa and 7.6% with the increase of 10.2%, 2.6% and 5.6% than that of reinforced by pre-oxidized SiC{sub p}. The more uniformly dispersed particles and better tensile properties of the Ti-coated SiC{sub p}/Al-Cu-Mg-Si-Mn composites could be attributed to the better wetting between Ti-coated SiC{sub p} and molten Al.

36 MATERIALS SCIENCE↗

Resilience Enhancement of Distribution Grids Against Extreme Weather Events

This paper proposes a resilience-oriented design (ROD) technique to protect distribution grids against high-impact but low-probability extreme weather events. The problem is formulated as a two-stage stochastic mixed integer problem. The first stage is to make ROD decisions, i.e., hardening existing distribution lines and deploying ROD resources such as back-up distributed generators and automatic switches. The second stage evaluates the system operation cost during a realized extreme weather event and repair cost after the event. A novel modeling strategy is proposed to deal with the decision-dependent uncertainty of distribution line damage status, which is affected by the first-stage hardening decisions. As both stages have binary variables, a modified and computationally efficient progressive hedging algorithm with scenario bundling is introduced. The algorithm performance is evaluated by calculating lower bounds of solutions. In conclusion, the proposed model and algorithms are demonstrated on 34-bus and 123-bus test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination of Wind Farm and Pumped-Storage Hydro for a Self-Healing Power Grid

The increasing penetration of wind energy poses great challenges to the operation of power systems in normal and emergency states. However, energy storage technologies can help accommodate wind power uncertainty and variability due to their flexible characteristics. This paper focuses on the restoration phase, and provides a novel coordination strategy of wind and pumped-storage hydro (PSH) units for a faster and reliable self-healing process. The wind-PSH assisted power system restoration is formulated as a two-stage adaptive robust optimization problem. The first-stage problem determines the start-up sequence of generators and the energization times of transmission paths; and the second-stage problem decides load pickup sequences, wind power dispatch levels, and PSH units' operating modes. The column-and-constraint generation decomposition algorithm is applied to solve the two-stage adaptive robust optimization problem, which has a mixed-integer optimization in the inner-level problem. The developed coordination strategy is tested on the modified IEEE 39-bus system. Numerical results demonstrate that the coordinated wind and PSH units can increase the total energy served, enhance wind power dispatchability, and reduce wind power curtailment.

17 WIND ENERGY↗

Towards the Robust Small-Signal Stability Region of Power Systems Under Perturbations Such as Uncertain and Volatile Wind Generation

This paper addresses how to extend the concept of small-signal stability region (SSSR) to that of robust small-signal stability region (RSSSR), within which the system can remain stable even under perturbations caused by uncertain and volatile nodal injections, such as renewable generation. We first employ the structured perturbation theory to formulate the perturbations of nodal injections in state space. Both the intensity and the locations of perturbations can be taken into account. Then, we leverage the stability radius theory and structured singular value theory to define the RSSSR in parameter subspace, enabling a systematic analysis of small-signal stability of power systems under perturbations in a region-wise manner. The hyperplane-approximation method can be employed to construct a linear closed-form approximation of RSSSR boundaries. Case studies on the modified two-area system and New England 39-node system illustrate the new concept of RSSSR and its potential applications.

power system stability analysis↗

Identification of Critical Switches for Integrating Renewable Distributed Generation by Dynamic Network Reconfiguration

With growing penetration of renewable distributed generations (DGs) in distribution systems, effective integration of DGs has become a major concern. Distribution system dynamic reconfiguration (DSDR), which relies on real-time operations of remote-controlled switches, is potentially an efficient strategy receiving inadequate attention. Moreover, in most DSDR-related publications, normally all switches are assumed remotely controllable, which is not practical. Here we borrow the concept of critical switches to denote the switches that are most effective in accommodating DGs by DSDR. In this regard, the problem of identifying critical switches is not well investigated, although in several related publications, selected switches are assumed remote-controlled based on experience. In this work, we study the application of DSDR for DG integration. Critical switches, which optimally enable intra-day DSDR to minimize DG curtailments, are identified by limiting the number of switches to be operated and the switch-type-dependent operation constraints. Considering uncertainties of loads and DGs, the problem is formulated as a two-stage robust optimization model solved by a nested column-and-constraint generation algorithm. Illustrative cases show that DG curtailments can be significantly reduced by a small number of critical switches that operate only several times in intra-day DSDR. The proposed method can be used to provide insights for switch allocation, maintenance, and operation

Lei, Shunbo (ORCID:0000000181690821)↗

Formaldehyde and co-exposure with benzene induce compensation of bone marrow and hematopoietic stem/progenitor cells in BALB/c mice during post-exposure period

Formaldehyde (FA) is a human leukemogen. Since there is a latency period between initial FA exposure and the development of leukemia, the subsequent impact of FA on hematopoietic stem or progenitor cells (HSCs/HPCs) in post-exposure stage is crucial for a deep understanding of FA-induced hematotoxicity. BALB/c mice were exposed to 3 mg/m{sup 3} FA for 2 weeks, mimicking occupational exposure, and were monitored for another 7 days post-exposure. Meanwhile, we included benzene (BZ) as a positive control, separately and together with FA because co-exposure occurs frequently. After 7-day recovery, colonies of progenitors for CFU-GM and BFU-E, and nucleated bone marrow cells in FA-exposed mice were comparable to controls, although they were significantly reduced during exposure. Levels of reactive oxygen species (ROS) and 8-hydroxy-2′-deoxyguanosine (8-OHdG) in CFU-GM and BFU-E from FA-exposed mice were higher than controls, although the increase in 8-OHdG was not significant. Granulocyte-macrophage colony stimulating factor (GM-CSF) level in the FA group was lower than controls, but the expression level for the receptor was not upregulated. It suggests that HSCs/HPCs in FA-exposed mice respond to a small amount of GM-CSF and proliferate rapidly, which may cause a possible risk of expansion of abnormal stem/progenitor cell clones. FA co-exposure with BZ was more potent for promoting CFU-GM formation and inducing ROS in BFU-E and 8-OHdG in CFU-GM during the post-exposure period. The compensation of myeloid progenitors with elevated ROS and 8-OHdG may lead to a risk of transforming normal HSCs/HPCs to leukemic stem/progenitor cells. Thus, co-exposure may pose a greater leukemia risk. - Highlights: • Nucleated bone marrow cell count recovered after 7 days post-FA and/or BZ exposure. • CFU-GM showed an increase in colonies and 8-OHdG after 7 days post-FA + BZ exposure. • Levels of ROS in CFU-GM and BFU-E were increased by FA or FA + BZ during recovery. • Levels of GM-CSF and EPOR were suppressed after 7 days post-FA or FA + BZ exposure. • Co-exposure was more potent for some endpoints and may pose a greater leukemia risk.

60 APPLIED LIFE SCIENCES↗

Optimal Black Start Resource Allocation

The restoration of the bulk power system after a partial or complete blackout relies on black-start (BS) resources. To prepare for system restoration, it is important to procure the right amount of BS resources at the right locations in the grid so that the total restoration time can be minimized. Achieving this goal requires that resource procurement planning takes the restoration process into account. In this study, we integrate the BS resource procurement decision with a restoration planning model and develop an optimization model that produces a minimal cost procurement plan that satisfies the restoration time requirement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Distribution System by Microgrids Formation After Natural Disasters

Microgrids with distributed generation provide a resilient solution in the case of major faults in a distribution system due to natural disasters. This paper proposes a novel distribution system operational approach by forming multiple microgrids energized by distributed generation from the radial distribution system in real-time operations, to restore critical loads from the power outage. Specifically, a mixed-integer linear program (MILP) is formulated to maximize the critical loads to be picked up while satisfying the self-adequacy and operation constraints for the microgrids formation problem, by controlling the ON/OFF status of the remotely controlled switch devices and distributed generation. A distributed multi-agent coordination scheme is designed via local communications for the global information discovery as inputs of the optimization, which is suitable for autonomous communication requirements after the disastrous event. The formed microgrids can be further utilized for power quality control and can be connected to a larger microgrid before the restoration of the main grids is complete. Numerical results based on modified IEEE distribution test systems validate the effectiveness of our proposed scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ultra-thin silicon/electro-optic polymer hybrid waveguide modulators

Ultra-thin silicon and electro-optic (EO) polymer hybrid waveguide modulators have been designed and fabricated. The waveguide consists of a silicon core with a thickness of 30 nm and a width of 2 μm. The cladding is an EO polymer. Optical mode calculation reveals that 55% of the optical field around the silicon extends into the EO polymer in the TE mode. A Mach-Zehnder interferometer (MZI) modulator was prepared using common coplanar electrodes. The measured half-wave voltage of the MZI with 7 μm spacing and 1.3 cm long electrodes is 4.6 V at 1550 nm. The evaluated EO coefficient is 70 pm/V, which is comparable to that of the bulk EO polymer film. Using ultra-thin silicon is beneficial in order to reduce the side-wall scattering loss, yielding a propagation loss of 4.0 dB/cm. We also investigated a mode converter which couples light from the hybrid EO waveguide into a strip silicon waveguide. The calculation indicates that the coupling loss between these two devices is small enough to exploit the potential fusion of a hybrid EO polymer modulator together with a silicon micro-photonics device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗