Thermoelectric heating and cooling–integrated dishwasher with thermal energy storage

Household dishwashers must address several performance goals: maximize washing and drying performance, while minimizing cycle duration, energy consumption, and water consumption. This study develops and examines a novel thermoelectric heating and cooling (TEHC) system with thermal energy storage applied to a household dishwasher (DW), aiming to improve the energy and drying performance of a commercially-available dishwasher while maintaining its washing performance, water consumption, and cycle duration. Experimental testing conducted on the novel TEHC-DW system demonstrates an 8.7% reduction in total energy consumption, lowering the per-cycle usage to 0.952 kWh, and a 40% reduction in energy consumption for internal water heating. The novel TEHC-DW system also demonstrates better drying performance, shortening the drying time by 42% to reach the same remaining moisture content as a commercially-available system. In addition, a resistance-capacitance network model is developed that predicts total drying time, total energy consumption, and the highest temperature reached in the tub (53.4 °C). The model accuracy is validated with experimental data (within ±1 K), and the model functions as a design tool via a parametric study to evaluate the next-generation design and the effect of the number of thermoelectric modules and thermoelectric driving force (i.e., current). Overall, this study demonstrates the potential for TEHC technology to improve energy efficiency and drying performance in household dishwashers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.