Engineering PapersSearch

Engineering topics

Qian Gong

Publications and source records attributed to Qian Gong.

At least 19 records

CODEX Optical Design and Alignment

The COronal Diagnostic EXperiment (CODEX) is a Heliophysics mission to measure the density, temperature, and velocity of the electrons in the solar corona with the primary goal of improving our understanding of the physical conditions of the solar wind in the acceleration region. The temperature and velocity measurement requires much higher signal-to-noise ratio than the density measurements. In solar coronagraphs, the diffraction of the solar disk light due to the occulting element is the dominant source of noise. Therefore, to further suppress the diffracted sun light with respect to the existing coronagraphs is a critical element of the CODEX design. To minimize the stray light due to diffraction, the selected optical design is a two-stage standard coronagraph with an external occulter, an internal occulter, and a Lyot stop. What is unique for this design is that a focal mask was inserted at the telescope focal plane. It works together with the field lens suppressing the stray light down by ~ another order of magnitude as compared to a traditional three-stage approach. During the optical design, a Fourier Transform based beam propagation software, i.e., GLAD, was used to model the beam path through the full coronagraph, from the external occulter to the detector array. All diffraction sensitive elements: external occulter, internal occulter, focal mask, and Lyot stop were carefully modeled and optimized. As a result, the requirement of achieving a stray light level which is one order of magnitude lower than F-corona was satisfied. On the other hand, to achieve the final suppression, a precision optical alignment is another must. This paper also presents our creative alignment procedure: using the combination of metrology, precision alignment equipment, and real time diffraction ring monitoring to minimize the diffraction. The final test results show that the suppression ratio (B/B 0 ) reaches 10 -11 level, which is equivalent to one order of magnitude lower than F-corona.

CODEX optical design and alignment

The NEID Port Adapter at WIYN: On-Sky Fast Guiding Performance

NEID (NN-explore Exoplanet Investigations with Doppler spectroscopy) is an optical, fiber-fed spectrometer installed on the WIYN 3.5m Telescope. The radial velocity precision that NEID is expected to reach requires the stellar jitter (i.e., the slight irregular movement of the stellar image induced by atmospheric turbulence, wind-shake, etc.) to be controlled within 0.05 arc-seconds 90% of the time in nominal observing conditions (i.e., 0.8-arcsecond seeing and mild winds). To achieve that, the NEID Port Adapter incorporates a fast, first-order wavefront correction system, which implements an Electron-Multiplying CCD camera and a tip/tilt piezo stage to capture and stabilize the stellar image. Here, we use on-sky data to demonstrate the performance of this system under various observing conditions.

Dan Li

The NEID Port Adapter on-Sky Performance

Here we detail the on-sky performance of the NEID Port Adapter one year into full science operation at the WIYN 3.5m Telescope at Kitt Peak National Observatory. NEID is an optical (380-930 nm), fiber-fed, precision Doppler radial velocity system developed as part of the NASA-NSF Exoplanet Observational Research (NN-EXPLORE) partnership. The NEID Port Adapter mounts directly to a bent-Cassegrain port on the WIYN Telescope and is responsible for precisely and stably placing target light on the science fibers. Precision acquisition and guiding is a critical component of such extreme precision spectrographs. In this work, we describe key on-sky performance results compared to initial design requirements and error budgets. While the current Port Adapter performance is more than sufficient for the NEID system to achieve and indeed exceed its formal instrumental radial velocity precision requirements, we continue to characterize and further optimize its performance and efficiency. This enables us to obtain better NEID datasets and in some cases, improve the performance of key terms in the error budget needed for future extreme precision spectrographs with the goal of observing ExoEarths, requiring ∼ 10 cm/s radial velocity measurements.

Sarah E. Logsdon

Modeling and Performance Analysis of the LUVOIR Coronagraph Instrument

Future space missions such as the Large UV/Optical/Infrared Surveyor (LUVOIR) and the Habitable Exoplanet Observatory, when equipped with coronagraphs with active wavefront control to suppress starlight, will allow the discovery and characterization of habitable exoplanets. The Extreme Coronagraph for Living Planetary Systems (ECLIPS) is the coronagraph instrument on the LUVOIR Surveyor mission concept, an 8- to 15-m segmented telescope. ECLIPS is split into three channels, namely, UV (200 to 400 nm), optical (400 to 850 nm), and near IR (850 nm to 2 μm), with each channel equipped with two deformable mirrors for wavefront control, a suite of coronagraph masks, a low-order/out-of-band wavefront sensor, and separate science imagers and spectrographs. The apodized pupil Lyot coronagraph and the vector vortex coronagraph are the baselined mask technologies for ECLIPS to enable the required 10−10 contrast for observations in the habitable zones of nearby stars for LUVOIR-A (15-m telescope) and LUVOIR-B (8-m telescope), respectively. Their performance depends on active wavefront sensing and control, as well as metrology subsystems to compensate for aberrations induced by segment errors (e.g., piston and tip/tilt), secondary mirror misalignment, and global low-order wavefront errors. Here, we present the latest results of the simulation of these effects for the LUVOIR coronagraph instrument and discuss the achieved contrast for exoplanet detection and characterization after closed-loop wavefront estimation and control algorithms have been applied. Finally, we show simulated observations using high-fidelity spatial and spectral input models of complete planetary systems generated with the Haystacks code framework.

Roser Juanola-Parramon

Characterization of Nancy Grace Roman Space Telescope Slitless Spectrometer (grism)

We have published the optical design and early test results of the Roman Space Telescope grism spectrometer in previous SPIE proceedings. We report the follow-on activity of the spectral and radiometric calibrations, including the calibration methods, experiment designs, and test equipment calibration, such as the light source and detectors used in the test. The grism calibration includes the throughput versus wavelength, which is largely determined by the diffraction efficiency of the two diffractive surfaces. It also includes spectral resolution, point spread function, and relative radiometric measurements. The measured results are presented. The comparisons between the test data and the theoretical simulations are also presented. The tests and results presented are from the engineering test unit in ambient room temperature environment. The thermal/vacuum tests are planned to verify the results when the flight unit is ready.

Qian Gong

Development of the WFIRST CGI Integral Field Spectrograph

The principal science goal of directly imaging exoplanets is spectroscopy. Future mission concepts such as LU- VOIR and HabEx have baselined their science instruments to use an integral field spectrograph (IFS) to maximize observing efficiency. Coronagraphic imaging with an IFS has strong heritage at ground observatories, having produced planet and brown dwarf near-infrared spectra at contrast floors as low as high 1 × 10-6 levels. As a technology demonstration for future missions the WFIRST coronagraph instrument (CGI) will demonstrate the ability to measure spectra in visible light with at contrast levels sufficient for detecting Earth-like planets. The spectrograph was originally meant to match that of future missions; an independent IFS channel for wavefront control and imaging spectroscopy. Due to a series of de-scopes as the project progressed, the baseline spectroscopic capability of CGI is no longer an IFS but a zero deviation optical prism and slit used in conjunction with the direct imaging camera. Regardless, CGI advanced a lenslet IFS through the preliminary design phase of a flight project. Here we present that development as the challenges and requirements of an IFS for coronagraphy are quite unique and relevant to future missions. With that development in place, we also present the initial design of the zero optical deviation prism, highlighting the relative challenges and performance of each concept.

Tyler D Groff

Optical Design of the Extreme Coronagraph for Living Planetary Systems Instrument for the LUVOIR Mission Study

The large UV/optical/IR surveyor (LUVOIR) is a concept for a highly capable, multiwavelength space observatory with ambitious science goals. Finding and characterizing a wide range of exoplanets, including those that might be habitable, is a major goal of the study. The ambitious science goals drive the challenges of optical design. This paper will present how the optical design meets the unique challenges for coronagraphs on large telescopes to achieve high contrast for a wide wavelength range from 200 to 2000 nm. Some of these unique challenges include the position and size of occulter masks, deformable mirror placement and separation, tight tolerances on the optical system and each element, and finally, packaging all instruments in a limited space. Three types of modules are designed after the coronagraph to explore the exoplanets and analyze the spectrum of detected exoplanet signals: two imaging cameras, two integral field spectrographs, and one high-resolution spectrometer. All of them work together to provide information to meet scientific challenges in searching for habitable planets. The optical designs, unique challenges, and the solutions for all coronagraph and spectral modules are presented. Their specifications derived from science goals are also presented.

Qian Gong

Optical design of the Extreme Coronagraph for Living Planetary Systems instrument for the LUVOIR mission study

The large UV/optical/IR surveyor (LUVOIR) is a concept for a highly capable, multiwavelength space observatory with ambitious science goals. Finding and characterizing a wide range of exoplanets, including those that might be habitable, is a major goal of the study. The ambitious science goals drive the challenges of optical design. This paper will present how the optical design meets the unique challenges for coronagraphs on large telescopes to achieve high contrast for a wide wavelength range from 200 to 2000 nm. Some of these unique challenges include the position and size of occulter masks, deformable mirror placement and separation, tight tolerances on the optical system and each element, and finally, packaging all instruments in a limited space. Three types of modules are designed after the coronagraph to explore the exoplanets and analyze the spectrum of detected exoplanet signals: two imaging cameras, two integral field spectrographs, and one high-resolution spectrometer. All of them work together to provide information to meet scientific challenges in searching for habitable planets. The optical designs, unique challenges, and the solutions for all coronagraph and spectral modules are presented. Their specifications derived from science goals are also presented.

Qian Gong

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Study Update

NASA commissioned the study of four large mission concepts, including the Large Ultraviolet / Optical / Infrared (LUVOIR) Surveyor, to be evaluated by the 2020 Decadal Survey in Astrophysics. In response, the Science and Technology Definition Team (STDT) identified a broad range of science objectives for LUVOIR that include the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the exchange of matter between galaxies, star and planet formation, and the remote sensing of Solar System objects. To meet these objectives, the LUVOIR Study Office, located at NASA’s Goddard Space Flight Center (GSFC), completed the first design iteration of a 15-m segmented-aperture observatory that would be launched by the Space Launch System (SLS) Block 2 configuration. The observatory includes four serviceable instruments: the Extreme Coronagraph for Living Planetary Systems (ECLIPS), an optical / near-infrared coronagraph capable of delivering 10^-10contrast at inner working angles as small as 2 O/D; the LUVOIR UV Multi-object Spectrograph (LUMOS), which will provide low- and medium-resolution UV (100 – 400 nm) multi-object imaging spectroscopy in addition to far-UV imaging; the High Definition Imager (HDI), a high-resolution wide-field-of-view NUV-Optical-NIR imager; and Pollux, a high-resolution UV spectro-polarimeter being contributed by Centre National d’Etudes Spatiales (CNES).The study team has executed a second design iteration to further improve upon the 15-m concept, while simultaneously studying an 8-m concept. In these proceedings, we provide an update on these two architectures.

space telescopes

The WFIRST CGI Integral Field Spectrograph: Requirements and Performance Predictions

The WFIRST coronagraphic instrument (CGI) will demonstrate exoplanet spectroscopy using an integral field spectrograph (IFS). The CGI IFS, being designed and built at Goddard Space Flight Center, has a spectral resolution of R50 and is designed to accommodate a 20% bandpass spanning 600- 970 nm. The IFS is principally targeting the abundance of Methane features, with the primary coronagraph band being centered around 770nm. Key to the performance estimates are the achievable signal-to-noise (SNR) ratios and the stability of the microspectra over the course of tens and hundreds of hours. As a technology demonstration for CGI, the ability to close a wavefront control loop around the IFS, maintain a stable dark hole, and provide time resolved data that simultaneously spans spatial and spectral dimensions are crucial demonstrations for future observatories. The IFS is optimized both for coronagraphs and science observations with a potential future starshade. We highlight how the long duration observations, and requirements for both starshades and coronagraphs drive the IFS requirements and the calibrations required both onorbit and on the ground. We also provide further detail on the optomechanical design, its stability based on thermal and structural predictions, anticipated performance, and operations concept of the CGI IFS. The impact of these performance metrics are projected into simulated data products, demonstrating cube extraction of noisy images and the subsequent planet spectrum that can be extracted from them. These demonstrations and performance predictions are key to future missions such as LUVOIR and HabEx, whose principal science case relies on efficient spectroscopy of exoplanets.

Tyler Groff

Prism Assembly for Roman Space Telescope Wide Field Instrument Slit-less Spectroscopy

The Roman Space Telescope (RST) is a three mirror anastigmat design with a 2.4 m primary mirror. RST will be based in L2 orbit, from where it will provide science information on exoplanets and dark energy using the Coronagraph Instrument (CGI) and Wide Field Instrument (WFI). The WFI features a 300 megapixel near-infrared detector array which provides a field of view 100 times larger than that of Hubble Space Telescope. The Prism Assembly is a small add-on instrument to the Roman Space Telescope’s Wide Field Instrument (WFI), installed in a slot in WFI’s element wheel. The Prism assembly has a passband from 0.75 µm to 1.8 µm, enabling a survey of redshifts in the range 0.2 to 1.7 µm. It provides low resolution slit-less spectroscopy with a spectral resolution R > 70 for all wavelengths, and R < 170 for λ > 0.8 µm across the full field. The Prism Assembly has the potential to provide more supernova spectra than ground-based spectroscopy during the mission lifetime. Being a late add-on to the RST mission, the Prism Assembly has had restrictions on size, weight and geometry, and a challenging schedule, which has dictated much of the implementation. Despite these challenges, the Prism Assembly is a pocket-sized high-performance spectrographic element, implemented as a refractive, all-spherical optical design using only two elements, one S-TIH-1 glass and one CaF2. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration. (100 words): The Roman Space Telescope is a three mirror anastigmat design with a 2.4 m primary mirror, which will provide science information on dark energy and exoplanets. The Prism Assembly is a small add-on instrument to the telescope’s Wide Field Instrument, enabling low resolution slit-less spectroscopy with a spectral resolution 70 < R < 170 across the full field from λ= 0.75 µm to 1.8 µm. The Prism Assembly is a refractive, all-spherical optical design using a glass and a CaF2 element. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration.

Space Instrumentation