Thermal Stability of Solid-State Battery Components with Liquid Electrolyte.
Abstract not provided.
Engineering topics
Publications and source records attributed to Preger, Yuliya.
Abstract not provided.
Abstract not provided.
Abstract not provided.
In recent years, the pervasive use of lithium ion (Li-ion) batteries in applications such as cell phones, laptop computers, electric vehicles, and grid energy storage systems has prompted the development of specialized battery management systems (BMS). The primary goal of a BMS is to maintain a reliable and safe battery power source while maximizing the calendar life and performance of the cells. To maintain safe operation, a BMS should be programmed to minimize degradation and prevent damage to a Li-ion cell, which can lead to thermal runaway. Cell damage can occur over time if a BMS is not properly configured to avoid overcharging and discharging. To prevent cell damage, efficient and accurate cell charging cycle characteristics algorithms must be employed. In this paper, computationally efficient and accurate ensemble learning algorithms capable of detecting Li-ion cell charging irregularities are described. Additionally, it is shown using machine and deep learning that it is possible to accurately and efficiently detect when a cell has experienced thermal and electrical stress due to cell overcharging by measuring charging cycle divergence.
Energy storage technologies are positioned to play a substantial role in power delivery systems. They have the potential to serve as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, because of their relative infancy, there is a lack of knowledge about how these resources truly operate over time. A data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and a data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verify the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data that the provider supplies for the analysis. After a review of energy storage data received from several providers, some of these data have clearly shown to be inconsistent and incomplete, raising the question of their efficacy for a robust analysis. This report reviews and proposes general guidelines, such as sampling rates and data points, that providers must supply for a robust data analysis to take place. Consistent guidelines are the basis of a proper protocol and ensuing standards to (1) reduce the time that it takes for data to reach those who are providing the analysis; (2) allow them to better understand the energy storage installations; and (3) enable them to provide a high-quality analysis of the installations. The report is intended to serve as a starting point for what data points should be provided when monitoring. Readers are encouraged to use the guidance in the report to develop specifications for new systems, as well as enhance current efforts to ensure optimal storage performance. As battery technologies continue to advance and the industry expands, the report will be updated to remain current.
Due to their impressive energy density, power density, lifetime, and cost, lithium-ion batteries have become the most important electrochemical storage system, with applications including consumer electronics, electric vehicles, and stationary energy storage. However, each application has unique, often conflicting product specifications, requiring a balanced overall assessment. The Ragone plot is a commonly-used plot to compare energy and power of lithium-ion battery chemistries. Important parameters including cost, lifetime, and temperature sensitivity are not considered. Overall, a standardized and balanced reporting and visualization of specifications would greatly help an informed cell selection process.
Abstract not provided.
Abstract not provided.
Applications of fiber optic sensors to battery monitoring have been increasing due to the growing need of enhanced battery management systems with accurate state estimations. The goal of this review is to discuss the advancements enabling the practical implementation of battery internal parameter measurements including local temperature, strain, pressure, and refractive index for general operation, as well as the external measurements such as temperature gradients and vent gas sensing for thermal runaway imminent detection. A reasonable matching is discussed between fiber optic sensors of different range capabilities with battery systems of three levels of scales, namely electric vehicle and heavy-duty electric truck battery packs, and grid-scale battery systems. The advantages of fiber optic sensors over electrical sensors are discussed, while electrochemical stability issues of fiber-implanted batteries are critically assessed. This review also includes the estimated sensing system costs for typical fiber optic sensors and identifies the high interrogation cost as one of the limitations in their practical deployment into batteries. Finally, future perspectives are considered in the implementation of fiber optics into high-value battery applications such as grid-scale energy storage fault detection and prediction systems.
Abstract not provided.
Abstract not provided.